File name: Pandora187s1_PittsburghPA_20231127_L2Fit_fnvs4c3d20220705p1-8.txt File generation date: 20231128T063258.7Z Data description: Level 2 spectral fitting results file Data file version: fnvs4c3p1-8 Local principal investigator: Lukas Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 187 Spectrometer number: 1 Processing software version used: BlickP v1.8.49 Instrument operation file used: Pandora187_OF_v4d20210517.txt Instrument calibration file used: Pandora187s1_CF_v3d20220705.txt Level 1 file used: Pandora187s1_PittsburghPA_20231127_L1_smca1c3d20220705p1-8.txt Full location name: Pittsburgh, PA - Lawrenceville ACHD (USEPA AQS ID 42-003-0008) Short location name: PittsburghPA Country of location: United States Location latitude [deg]: 40.4655 Location longitude [deg]: -79.9608 Location altitude [m]: 265 Local noon date: 20231127 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 886 1427 Nominal wavelengths inside fitting window [nm]: 400.1238 400.2567 400.3896 400.5224 400.6553 400.7881 400.9209 401.0537 401.1865 401.3193 401.4520 401.5848 401.7175 401.8502 401.9829 402.1156 402.2483 402.3809 402.5136 402.6462 402.7788 402.9114 403.0440 403.1766 403.3092 403.4417 403.5743 403.7068 403.8393 403.9718 404.1043 404.2367 404.3692 404.5016 404.6340 404.7664 404.8988 405.0312 405.1636 405.2959 405.4283 405.5606 405.6929 405.8252 405.9575 406.0898 406.2220 406.3543 406.4865 406.6187 406.7509 406.8831 407.0152 407.1474 407.2795 407.4117 407.5438 407.6759 407.8080 407.9400 408.0721 408.2041 408.3362 408.4682 408.6002 408.7322 408.8642 408.9961 409.1281 409.2600 409.3919 409.5238 409.6557 409.7876 409.9194 410.0513 410.1831 410.3149 410.4467 410.5785 410.7103 410.8421 410.9738 411.1055 411.2373 411.3690 411.5007 411.6323 411.7640 411.8956 412.0273 412.1589 412.2905 412.4221 412.5537 412.6852 412.8168 412.9483 413.0798 413.2113 413.3428 413.4743 413.6058 413.7372 413.8687 414.0001 414.1315 414.2629 414.3942 414.5256 414.6570 414.7883 414.9196 415.0509 415.1822 415.3135 415.4448 415.5760 415.7072 415.8385 415.9697 416.1009 416.2320 416.3632 416.4944 416.6255 416.7566 416.8877 417.0188 417.1499 417.2810 417.4120 417.5430 417.6741 417.8051 417.9361 418.0670 418.1980 418.3289 418.4599 418.5908 418.7217 418.8526 418.9835 419.1143 419.2452 419.3760 419.5068 419.6376 419.7684 419.8992 420.0300 420.1607 420.2915 420.4222 420.5529 420.6836 420.8142 420.9449 421.0755 421.2062 421.3368 421.4674 421.5980 421.7286 421.8591 421.9897 422.1202 422.2507 422.3812 422.5117 422.6422 422.7726 422.9031 423.0335 423.1639 423.2943 423.4247 423.5551 423.6854 423.8158 423.9461 424.0764 424.2067 424.3370 424.4673 424.5975 424.7278 424.8580 424.9882 425.1184 425.2486 425.3787 425.5089 425.6390 425.7692 425.8993 426.0294 426.1594 426.2895 426.4196 426.5496 426.6796 426.8096 426.9396 427.0696 427.1995 427.3295 427.4594 427.5893 427.7192 427.8491 427.9790 428.1089 428.2387 428.3685 428.4984 428.6282 428.7579 428.8877 429.0175 429.1472 429.2769 429.4067 429.5364 429.6660 429.7957 429.9254 430.0550 430.1846 430.3142 430.4438 430.5734 430.7030 430.8325 430.9620 431.0916 431.2211 431.3506 431.4800 431.6095 431.7389 431.8684 431.9978 432.1272 432.2566 432.3860 432.5153 432.6447 432.7740 432.9033 433.0326 433.1619 433.2911 433.4204 433.5496 433.6789 433.8081 433.9373 434.0664 434.1956 434.3247 434.4539 434.5830 434.7121 434.8412 434.9703 435.0993 435.2284 435.3574 435.4864 435.6154 435.7444 435.8734 436.0023 436.1313 436.2602 436.3891 436.5180 436.6469 436.7757 436.9046 437.0334 437.1622 437.2910 437.4198 437.5486 437.6774 437.8061 437.9348 438.0635 438.1922 438.3209 438.4496 438.5783 438.7069 438.8355 438.9641 439.0927 439.2213 439.3499 439.4784 439.6069 439.7355 439.8640 439.9924 440.1209 440.2494 440.3778 440.5062 440.6347 440.7631 440.8914 441.0198 441.1482 441.2765 441.4048 441.5331 441.6614 441.7897 441.9179 442.0462 442.1744 442.3026 442.4308 442.5590 442.6872 442.8153 442.9435 443.0716 443.1997 443.3278 443.4559 443.5840 443.7120 443.8400 443.9681 444.0961 444.2240 444.3520 444.4800 444.6079 444.7358 444.8637 444.9916 445.1195 445.2474 445.3752 445.5031 445.6309 445.7587 445.8865 446.0143 446.1420 446.2698 446.3975 446.5252 446.6529 446.7806 446.9082 447.0359 447.1635 447.2911 447.4187 447.5463 447.6739 447.8015 447.9290 448.0565 448.1840 448.3115 448.4390 448.5665 448.6939 448.8214 448.9488 449.0762 449.2036 449.3310 449.4583 449.5857 449.7130 449.8403 449.9676 450.0949 450.2222 450.3494 450.4766 450.6039 450.7311 450.8583 450.9854 451.1126 451.2397 451.3669 451.4940 451.6211 451.7481 451.8752 452.0023 452.1293 452.2563 452.3833 452.5103 452.6373 452.7642 452.8912 453.0181 453.1450 453.2719 453.3988 453.5256 453.6525 453.7793 453.9061 454.0329 454.1597 454.2865 454.4133 454.5400 454.6667 454.7934 454.9201 455.0468 455.1735 455.3001 455.4267 455.5534 455.6800 455.8065 455.9331 456.0597 456.1862 456.3127 456.4392 456.5657 456.6922 456.8186 456.9451 457.0715 457.1979 457.3243 457.4507 457.5771 457.7034 457.8298 457.9561 458.0824 458.2087 458.3349 458.4612 458.5874 458.7137 458.8399 458.9661 459.0922 459.2184 459.3445 459.4707 459.5968 459.7229 459.8490 459.9750 460.1011 460.2271 460.3532 460.4792 460.6051 460.7311 460.8571 460.9830 461.1089 461.2349 461.3608 461.4866 461.6125 461.7383 461.8642 461.9900 462.1158 462.2416 462.3673 462.4931 462.6188 462.7446 462.8703 462.9959 463.1216 463.2473 463.3729 463.4985 463.6242 463.7498 463.8753 464.0009 464.1264 464.2520 464.3775 464.5030 464.6285 464.7539 464.8794 465.0048 465.1302 465.2557 465.3810 465.5064 465.6318 465.7571 465.8824 466.0077 466.1330 466.2583 466.3836 466.5088 466.6341 466.7593 466.8845 467.0096 467.1348 467.2600 467.3851 467.5102 467.6353 467.7604 467.8855 468.0105 468.1356 468.2606 468.3856 468.5106 468.6356 468.7605 468.8855 469.0104 469.1353 469.2602 469.3851 469.5099 469.6348 469.7596 469.8844 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Temperature at electronics board [°C], 999=no temperature signal Column 159: Spectrometer control temperature [°C], 999=no temperature signal Column 160: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 161: Temperature in head sensor [°C], 999=no temperature signal Column 162: Humidity in head sensor [%], -9=no humidity signal Column 163: Pressure in head sensor [hPa], -9=no pressure signal Columns 164-705: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 706-1247: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20231127T163711.7Z 8731.692497 403 1 45.81 2 62.03 172.01 114.24 349.17 0.00 1 0.00 1 0 33 9.650e-04 9.420e-04 9.489e-04 9.291e-04 -1.001075e+03 1.943759e+02 8.866748e+01 3.326798e+02 2.038574e+02 278.00 -2.00 20.00 -2.00 445.29 0.00e+00 7.040460e-06 1.051752e-04 7.333144e-06 1.370865e-05 1.082897e-04 278.00 -2.00 20.00 -2.00 454.92 0.00e+00 1.836447e-04 1.038522e-05 1.358462e-05 1.266277e-05 1.083841e-05 278.00 -2.00 20.00 -2.00 435.60 0.00e+00 7.517691e+04 1.350777e+05 2.169814e+04 2.061838e+05 1.435780e+05 259.64 -2.00 11.20 -2.00 457.56 0.00e+00 3.021732e-01 2.646211e-02 4.054449e-03 8.715470e-03 3.058923e-02 223.03 -2.00 3.49 -2.00 454.32 0.00e+00 -8.219474e-08 3.413628e-06 3.773203e-07 1.033239e-06 3.817317e-06 278.00 -2.00 20.00 -2.00 455.61 0.00e+00 2.121 0.000 397.00 473.00 4 6.3588e+00 1.0392e-03 5.2684e-03 3.5642e-04 1.0336e-03 7.2102e-02 1.2072e-03 1.0935e-03 2.1348e-04 1.2464e-03 -9.2741e-03 7.0175e-04 1.4429e-04 8.9569e-05 7.1774e-04 5.6476e-04 2.3438e-04 1.9186e-05 2.3026e-05 2.4180e-04 1.4106e-03 1.1852e-04 1.0147e-05 1.2332e-05 1.1880e-04 2.0667e-03 5.8675e-03 7.2465e-04 6.9376e-05 3.6716e-05 6.5720e-04 -6.7997e-05 1.2704e-05 3.3631e-07 3.6324e-07 1.3115e-05 1.1584e-04 1.7401e-05 2.7928e-07 4.8798e-07 1.7941e-05 -1.6070e-02 -2.3192e-05 -1.3058e+00 1.0163e-01 4.4054e-03 2.3361e-03 9.8224e-02 10 0 0 10 0 0 99.94 18.87 0.70 -0.01607 -0.02741 34 10 1 4 0 1347.010 22.29 15.00 18.87 7.16 27.2 892.50 -39 122 139 37 -39 -162 68 -135 176 9 115 -12 -34 -13 228 109 -71 -69 98 -33 32 -142 25 83 -14 99 107 49 179 107 32 124 -39 -35 -164 -117 11 -31 71 66 54 -157 170 -8 189 -191 -201 -44 -149 17 144 -155 77 -83 -45 129 61 -64 -175 -7 29 23 -3 -45 23 -15 -25 77 20 -120 -100 86 -69 -125 -135 -34 -117 137 -108 4 86 -100 89 -108 118 -51 -20 -5 -21 -27 -55 136 -22 102 -245 -163 -164 -25 -136 57 -215 -632 -9 -51 92 -64 161 -162 80 -149 43 -90 -97 3 -101 -120 -254 -19 -111 9 7 62 72 81 -20 61 54 -103 49 28 -60 -84 -17 79 -92 -1 143 6 31 62 251 9 52 169 141 19 28 84 42 -14 153 50 -7 -17 38 -39 29 2 -4 -83 65 -3 -23 -11 15 154 -108 -115 -44 81 -40 -89 -26 -20 -58 87 77 64 224 214 84 279 213 85 141 81 123 61 -54 155 -106 -142 61 94 -39 103 -24 -112 148 97 -35 212 -13 193 60 -121 -47 1 132 -32 -40 21 -60 26 150 -52 89 89 -70 63 9 79 160 59 41 14 -69 161 143 58 -13 -159 -159 9 16 18 -15 21 -44 77 205 -37 166 -82 156 0 33 54 -1 -27 -62 126 -111 -61 -21 72 -139 66 148 284 -127 6 19 -83 -59 -78 -108 49 103 68 -2 -205 -213 -54 -67 -100 -50 -71 -50 -87 49 -163 -62 -75 -107 -131 -65 -71 -43 -126 -198 -35 -54 -56 -123 65 -213 -53 -30 27 105 -105 -149 24 -79 -46 48 -86 -56 -110 -93 30 21 -117 -16 -81 -64 96 65 -31 -60 -63 -53 -13 -70 -119 -33 9 169 -64 22 -25 31 -44 17 -20 35 -49 59 48 60 -125 9 -110 27 -10 -62 41 66 103 -5 140 8 69 61 36 -23 10 112 19 101 160 26 220 -5 59 -40 -221 -2 -12 40 -27 7 -41 90 -29 186 -60 15 28 -33 -189 -76 -7 88 -84 43 37 -24 75 -23 -89 -30 -66 -66 46 21 274 -29 70 99 -77 -63 -88 -128 64 -15 -33 130 100 -91 -79 -45 -1 -48 -65 67 79 128 52 -4 83 -75 11 11 116 56 -30 -16 -4 72 -78 70 0 55 18 -57 2 -6 -16 -18 41 -91 31 -11 -146 90 -25 46 -1 -81 82 -109 -80 -9 113 -14 -107 -44 9 41 -4 -26 135 -62 0 78 74 83 -101 -82 -146 -7 -115 123 -119 -51 68 -14 0 81 -79 56 134 -9 -32 22 43 124 156 81 57 90 100 41 -5 -192 -28 2 26 33 -59 -72 -136 -105 19 2 36 148 -40 -2 18 40 -34 66 134 58 35 11 96 -86 13 -179 86 29 -46 148 -101 -9 12 63 -57 -8 50 -49 24 -94 -65 -101 -65 8 -90 -33 102 113 29 -31 -131 56 -111 146 7 96 -10 -28 -11 191 92 -61 -59 83 -29 27 -123 21 66 -12 80 91 44 156 94 29 107 -32 -29 -133 -99 9 -28 64 59 47 -133 149 -7 166 -167 -172 -37 -124 15 127 -141 69 -74 -41 114 54 -56 -154 -6 26 21 -3 -41 21 -15 -24 75 19 -115 -93 82 -63 -111 -119 -29 -97 116 -97 3 82 -98 84 -102 114 -50 -20 -5 -21 -27 -54 133 -21 101 -240 -158 -158 -23 -133 54 -208 -599 -9 -52 95 -66 160 -155 79 -141 42 -89 -96 3 -98 -115 -243 -18 -107 9 7 64 75 85 -21 63 54 -103 48 26 -59 -82 -16 75 -89 -1 138 6 30 60 239 9 50 164 140 20 29 83 40 -13 146 48 -6 -16 37 -39 29 2 -4 -84 65 -3 -22 -11 15 151 -107 -114 -44 76 -37 -79 -23 -18 -56 84 75 64 216 204 81 271 202 82 138 79 119 58 -52 147 -101 -138 59 89 -36 100 -23 -107 141 91 -34 211 -13 183 56 -108 -40 1 117 -30 -37 20 -57 24 140 -48 81 83 -64 57 8 71 146 54 36 12 -58 126 112 45 -10 -125 -123 6 12 14 -12 17 -39 71 197 -38 172 -84 151 0 29 49 -1 -25 -58 124 -112 -62 -21 68 -131 57 127 239 -111 5 18 -79 -57 -77 -105 46 96 63 -2 -199 -211 -54 -65 -98 -50 -72 -51 -86 49 -158 -62 -73 -104 -125 -62 -68 -42 -122 -186 -32 -47 -48 -108 60 -195 -50 -29 26 102 -99 -143 23 -76 -44 44 -82 -52 -103 -88 28 20 -116 -16 -78 -64 94 64 -29 -58 -63 -52 -13 -68 -116 -32 9 166 -63 21 -24 29 -42 16 -19 35 -49 58 47 59 -125 9 -112 28 -10 -60 39 64 97 -5 131 8 66 57 34 -23 10 110 19 101 162 27 221 -5 60 -40 -226 -2 -12 40 -28 7 -43 93 -30 189 -61 16 29 -34 -196 -80 -7 90 -87 45 39 -26 80 -24 -94 -32 -72 -71 49 22 291 -31 75 106 -82 -65 -92 -132 64 -15 -33 130 101 -93 -82 -48 -2 -50 -69 71 84 140 57 -5 88 -79 11 11 123 60 -33 -17 -5 81 -88 79 0 61 20 -64 3 -7 -18 -20 47 -103 35 -12 -164 99 -27 51 -1 -91 92 -119 -89 -10 125 -16 -122 -51 10 47 -5 -29 155 -72 0 91 87 95 -115 -94 -168 -8 -137 145 -141 -60 81 -17 0 94 -92 65 155 -10 -38 26 49 149 186 97 68 106 117 49 -6 -225 -32 3 30 37 -68 -83 -158 -123 22 2 42 176 -48 -2 22 47 -40 74 148 63 39 12 110 -100 16 -212 101 34 -54 171 -118 -11 14 75 -68 -10 59 -58 28 -111 -73 -115 -77 9 -103 SQ 20231127T164456.7Z 8731.697878 409 1 45.54 2 61.85 174.05 114.47 350.99 0.00 1 0.00 1 0 33 8.216e-04 8.112e-04 8.935e-04 8.754e-04 -1.092909e+03 1.815525e+02 9.761470e+01 3.326551e+02 1.735566e+02 278.00 -2.00 20.00 -2.00 445.09 0.00e+00 -2.157614e-04 9.843581e-05 7.578702e-06 1.346300e-05 9.214107e-05 278.00 -2.00 20.00 -2.00 454.77 0.00e+00 1.840534e-04 9.810786e-06 1.384258e-05 1.266287e-05 9.227633e-06 278.00 -2.00 20.00 -2.00 435.42 0.00e+00 -1.060633e+05 1.269640e+05 2.282453e+04 2.062105e+05 1.222340e+05 259.64 -2.00 11.20 -2.00 457.38 0.00e+00 3.471505e-01 2.498952e-02 4.166946e-03 8.827370e-03 2.604174e-02 223.03 -2.00 3.49 -2.00 454.18 0.00e+00 4.345699e-06 3.217775e-06 3.904861e-07 1.032331e-06 3.249916e-06 278.00 -2.00 20.00 -2.00 455.49 0.00e+00 2.109 0.000 397.00 473.00 4 6.1981e+00 9.7925e-04 5.2398e-03 3.5530e-04 8.8047e-04 7.5526e-02 1.1295e-03 1.0872e-03 2.1086e-04 1.0600e-03 -7.2312e-03 6.5710e-04 1.4343e-04 8.7827e-05 6.1057e-04 1.2580e-03 2.1935e-04 1.9872e-05 2.2618e-05 2.0571e-04 1.4605e-03 1.1148e-04 1.0575e-05 1.2294e-05 1.0115e-04 2.4379e-03 5.2532e-03 6.8577e-04 6.9709e-05 3.6842e-05 5.6090e-04 -6.6917e-05 1.1985e-05 3.3072e-07 3.6188e-07 1.1166e-05 1.1981e-04 1.6415e-05 2.8077e-07 4.8314e-07 1.5275e-05 -1.6029e-02 -2.3476e-05 -1.2907e+00 9.5923e-02 4.5485e-03 2.4200e-03 8.3628e-02 10 0 0 10 0 0 99.92 18.87 0.64 -0.01603 -0.02768 50 15 1 4 0 910.600 22.29 15.00 18.87 7.51 27.2 894.61 101 32 1 62 10 -44 200 -105 205 84 72 -14 107 -18 34 -47 57 24 12 -8 85 -129 74 -91 53 43 -50 15 -77 1 153 153 27 -116 -197 -41 27 -69 12 -37 -21 -10 -39 -58 116 -98 50 30 -100 -23 59 -147 114 10 -66 64 85 -54 -66 61 -34 14 -65 -97 77 13 20 34 -59 -13 -56 28 -182 -110 -137 67 -58 -26 -65 102 79 -89 108 -66 89 -103 -82 -38 -109 -93 -2 50 -89 -79 -125 -196 -26 -9 -81 -46 -170 168 10 -66 -56 -2 102 -101 -35 -94 -67 -91 -73 72 -149 -21 -142 -2 -127 -44 15 86 137 17 -36 -18 30 -67 84 -17 -23 -65 -101 30 50 138 51 60 -37 91 106 72 -70 95 -51 70 47 40 245 -4 35 -62 -85 -48 13 11 37 53 54 -45 60 104 -114 113 -62 288 -48 -153 71 81 -54 -3 -29 -53 23 111 -19 65 45 99 6 93 27 164 150 217 76 37 -137 59 -13 -23 43 93 -90 150 -59 -73 159 121 -47 26 -21 88 67 -124 49 91 134 17 -68 35 23 40 115 78 83 118 -10 61 90 54 20 38 -84 -40 -70 107 72 113 -18 -207 17 -36 70 -34 -2 -5 -51 -24 65 18 208 76 47 -7 18 94 84 -26 71 -50 -38 -113 96 13 -35 53 -27 81 45 4 -36 -9 -70 -10 41 164 -116 -1 -10 -12 -175 -127 -84 -182 -30 -94 68 -66 90 -5 -107 -39 -119 28 -68 -37 -158 -109 -154 45 -11 -37 -67 -36 -254 -26 -40 -26 41 -114 -117 -112 -56 -18 -175 -150 -16 -134 -52 47 -32 -104 39 -132 -85 3 23 -11 85 -81 -61 -59 -4 -98 34 -59 193 14 -81 -20 56 -109 114 -40 28 -112 56 -8 50 -118 -77 -121 84 -43 122 -25 -58 115 53 86 -18 -45 70 22 27 -123 50 265 144 197 -44 188 -2 -85 -122 -61 -36 57 14 7 57 45 -20 88 91 -171 25 82 -11 20 8 -56 -82 -127 17 -35 51 -45 30 24 -10 -78 -120 107 -52 136 -64 123 47 -10 38 -185 -44 2 39 42 126 35 -31 -49 110 -116 -32 7 -70 41 122 14 -90 41 -50 -10 9 75 77 14 -60 56 60 -67 26 9 103 30 -68 107 99 -44 -28 41 -73 -53 11 -63 39 57 28 52 -7 131 -9 -73 -33 109 -78 -40 -97 -57 97 -71 34 28 -45 33 -24 69 129 64 55 -78 -105 46 49 -17 20 20 -11 -36 45 48 7 -55 48 -40 30 5 59 -86 -49 66 -44 37 74 30 -76 12 49 10 -33 9 -69 -204 -14 -27 52 34 51 -18 -4 35 76 -128 107 172 6 69 -30 -83 -64 53 -107 82 -44 -8 -32 30 -71 45 -14 70 49 59 16 -62 -90 -62 17 -26 40 -159 84 26 1 49 8 -35 164 -89 176 73 62 -12 92 -16 30 -41 50 21 10 -7 74 -110 61 -76 44 36 -42 13 -70 1 136 131 23 -94 -159 -34 24 -60 11 -32 -19 -9 -33 -51 101 -84 42 24 -82 -20 51 -131 102 9 -58 56 74 -46 -57 54 -31 13 -62 -92 75 12 20 33 -56 -12 -54 26 -166 -96 -120 56 -48 -22 -58 91 74 -86 105 -65 89 -100 -81 -38 -107 -90 -2 51 -86 -76 -127 -198 -26 -9 -78 -44 -162 164 10 -66 -57 -2 99 -100 -34 -92 -67 -88 -72 73 -150 -20 -140 -2 -126 -44 15 87 141 18 -37 -18 30 -65 84 -17 -23 -63 -98 29 49 138 51 60 -37 90 104 71 -70 91 -50 70 47 39 242 -3 33 -59 -81 -48 13 11 38 55 56 -47 63 106 -116 112 -62 289 -49 -156 70 75 -49 -3 -26 -51 22 111 -19 63 43 93 6 89 27 163 152 219 76 35 -130 55 -12 -22 41 91 -88 144 -56 -68 150 117 -45 26 -20 86 62 -109 43 81 117 15 -66 34 22 39 110 74 78 109 -9 54 79 48 18 34 -74 -35 -58 83 56 86 -14 -160 13 -27 52 -26 -1 -4 -44 -22 65 18 210 76 47 -7 16 83 76 -24 68 -48 -38 -112 93 13 -32 47 -23 67 39 4 -33 -9 -67 -10 39 159 -112 -1 -10 -11 -169 -124 -83 -183 -30 -97 70 -67 90 -4 -105 -37 -112 26 -63 -34 -150 -103 -148 41 -10 -32 -58 -32 -238 -24 -37 -25 39 -110 -114 -110 -55 -18 -167 -139 -15 -122 -48 44 -31 -100 38 -130 -82 3 22 -11 84 -81 -61 -59 -4 -97 34 -59 192 14 -79 -19 54 -106 112 -40 28 -113 56 -8 50 -115 -76 -120 82 -44 121 -24 -54 106 49 79 -17 -42 67 22 27 -123 50 266 146 194 -44 191 -3 -87 -124 -60 -36 58 15 6 57 45 -20 87 94 -177 26 85 -11 20 8 -58 -86 -134 19 -37 55 -49 32 26 -11 -83 -126 111 -56 146 -70 132 51 -11 40 -190 -44 2 40 42 129 36 -32 -52 114 -123 -34 7 -75 44 129 15 -98 44 -54 -10 9 81 83 16 -66 61 65 -74 29 10 116 34 -77 121 113 -51 -33 47 -85 -62 13 -72 43 63 30 56 -7 144 -10 -81 -37 123 -87 -45 -108 -64 107 -79 38 31 -51 37 -27 79 150 75 65 -92 -122 53 57 -20 23 24 -13 -42 52 56 8 -64 57 -47 36 5 69 -101 -57 76 -50 42 85 34 -86 14 58 12 -38 10 -81 -242 -16 -30 60 39 59 -21 -4 41 88 -151 124 194 6 78 -34 -97 -72 61 -123 95 -50 -10 -36 34 -80 51 -16 81 57 68 19 -71 -103 -71 20 -30 45 -179 SQ 20231127T164910.4Z 8731.700815 412 1 30.87 2 61.78 175.16 114.57 351.98 0.00 1 0.00 1 0 33 2.139e-03 2.110e-03 2.026e-03 1.982e-03 -1.195998e+03 4.172859e+02 1.174113e+02 3.326934e+02 4.518698e+02 278.00 -2.00 20.00 -2.00 445.39 0.00e+00 -4.477549e-04 2.245684e-04 9.141417e-06 1.367723e-05 2.397690e-04 278.00 -2.00 20.00 -2.00 455.01 0.00e+00 2.262736e-04 2.218851e-05 1.709869e-05 1.266449e-05 2.402560e-05 278.00 -2.00 20.00 -2.00 435.70 0.00e+00 -2.866191e+05 2.885132e+05 2.882441e+04 2.061724e+05 3.181688e+05 259.64 -2.00 11.20 -2.00 457.65 0.00e+00 3.138309e-01 5.608397e-02 4.896896e-03 8.692966e-03 6.779832e-02 223.03 -2.00 3.49 -2.00 454.43 0.00e+00 1.020916e-05 7.226638e-06 4.294212e-07 1.032968e-06 8.460516e-06 278.00 -2.00 20.00 -2.00 455.69 0.00e+00 2.104 0.000 397.00 473.00 4 7.3602e+00 2.2233e-03 5.2457e-03 3.5645e-04 2.2960e-03 6.8689e-02 2.5823e-03 1.0845e-03 2.1301e-04 2.7652e-03 -8.8042e-03 1.4989e-03 1.4282e-04 8.9111e-05 1.5903e-03 2.3677e-03 4.9960e-04 2.1875e-05 2.2862e-05 5.3486e-04 1.6230e-03 2.5283e-04 1.2780e-05 1.2324e-05 2.6336e-04 7.7288e-04 -2.0107e-03 1.5361e-03 8.6121e-05 3.7186e-05 1.4682e-03 -1.3768e-04 2.7297e-05 3.6410e-07 3.6224e-07 2.9069e-05 9.9821e-05 3.7444e-05 2.9303e-07 4.9051e-07 3.9768e-05 -1.6903e-02 1.2978e-07 -8.8221e-01 2.1687e-01 5.5364e-03 2.3903e-03 2.1744e-01 12 9 9 12 1 1 99.81 18.87 0.71 -0.01690 -0.02841 7 4 1 4 0 3855.040 22.29 15.00 18.87 7.61 27.2 894.86 188 52 97 -29 319 28 256 -318 214 96 -197 -312 349 154 124 139 97 238 -203 216 -179 -329 -170 180 -291 -83 -125 118 128 258 -169 154 -138 -175 -547 -21 231 42 152 -125 96 -272 -94 -207 167 -297 4 115 -465 129 238 -129 254 -259 -86 277 76 -51 94 226 193 5 -414 -12 -246 -30 -21 79 142 -178 -161 228 211 219 -382 311 -212 103 -325 -274 518 70 112 -77 360 -258 -71 99 -165 -410 -173 -76 79 -250 -466 -388 169 -245 -126 283 -9 180 177 -168 62 -144 554 -368 153 -187 171 -142 -60 -49 -44 35 -436 -186 -343 340 11 113 258 268 -210 325 64 -255 178 248 92 -62 -462 28 -82 254 283 -164 -117 306 26 116 91 334 -39 212 5 -93 402 -46 338 49 -219 -73 126 -150 29 -17 -8 95 25 45 28 -218 153 182 -488 -34 -130 -111 -163 -192 76 -428 -136 189 -114 67 178 586 -8 384 -21 -39 -84 43 -30 -94 -100 186 -360 -285 29 256 -280 29 -231 -9 383 271 -198 372 185 184 150 -177 -156 -2 186 102 -283 -129 2 58 83 326 231 422 -56 109 -162 64 173 29 -252 -296 -168 565 460 -99 241 -506 -152 -171 172 -160 337 -330 303 -58 477 -50 234 54 200 317 54 138 -2 35 -367 52 176 -160 -85 249 100 -117 -6 368 -153 -36 -181 -119 -166 23 -148 12 217 293 -37 -59 -351 -207 -63 -371 -93 16 138 -52 93 -32 -315 -26 -193 -36 -6 -65 -497 -63 -24 325 -196 19 -121 91 -456 -330 142 -7 311 -86 -41 -242 -72 25 472 -153 -5 -385 -55 210 130 -269 158 -254 -270 68 -44 -23 65 -116 -91 -232 -193 -20 296 -64 94 37 -153 -540 172 -316 -24 -264 315 -65 123 249 271 -152 -88 -38 12 107 158 88 -245 419 -321 -118 -129 -83 67 53 -84 -127 97 270 225 312 -61 592 101 -115 -162 -570 -425 89 -2 -2 205 167 50 86 314 -212 39 324 -129 -292 -94 -65 -275 -209 -41 279 182 -3 290 20 193 -176 -97 102 253 654 -22 35 155 -71 -153 -160 -341 -86 57 128 -165 273 27 218 -142 -261 13 -63 -295 281 129 27 -119 -26 -73 -104 233 -7 180 -206 -253 -40 168 220 -69 115 129 21 -4 207 -82 65 6 121 -193 55 -30 -229 104 81 -70 -77 -139 217 -136 123 -102 409 -107 -115 -281 -286 28 -181 218 259 199 -306 407 306 245 6 -294 -289 -112 -134 242 70 -3 256 108 0 -79 -9 -49 312 -426 26 156 -408 298 -114 161 196 -123 46 85 -151 -136 -39 -104 -83 -153 -107 -194 -306 -271 -23 211 118 190 -118 85 -64 36 -306 -16 462 -115 270 43 -219 -181 89 -244 314 -2 -139 404 -62 69 264 322 -19 -27 102 89 -131 -57 -196 -367 74 245 -265 155 43 78 -23 249 23 211 -271 184 83 -171 -270 300 133 107 121 85 208 -179 191 -158 -283 -140 150 -240 -70 -106 104 116 234 -151 132 -117 -142 -442 -18 194 37 135 -110 82 -238 -81 -180 145 -256 3 95 -383 108 207 -115 225 -230 -76 242 66 -44 81 200 178 5 -376 -11 -227 -29 -21 77 136 -168 -148 213 192 191 -334 258 -174 86 -289 -246 483 67 108 -75 341 -251 -71 98 -162 -399 -167 -73 77 -243 -451 -373 168 -240 -122 268 -9 175 170 -167 63 -145 538 -365 148 -183 171 -138 -59 -47 -42 34 -431 -183 -341 327 11 114 266 277 -217 329 63 -251 171 244 89 -59 -447 28 -78 242 270 -157 -111 289 24 114 86 319 -38 211 5 -90 378 -44 317 46 -210 -69 121 -150 30 -17 -8 94 24 46 29 -218 152 184 -479 -35 -128 -103 -148 -169 68 -389 -131 189 -114 65 169 549 -8 368 -21 -39 -81 42 -29 -92 -95 173 -340 -273 28 249 -274 28 -219 -8 362 264 -191 364 179 180 139 -156 -140 -2 163 94 -273 -121 1 54 76 311 217 390 -50 97 -143 57 156 26 -224 -251 -139 437 359 -76 185 -393 -117 -129 128 -121 267 -273 262 -53 472 -50 238 54 192 297 49 123 -2 32 -359 51 175 -159 -83 234 93 -106 -5 306 -132 -32 -168 -111 -159 23 -142 11 209 282 -35 -57 -343 -205 -63 -378 -91 16 137 -51 94 -32 -311 -25 -185 -34 -6 -62 -479 -61 -22 297 -171 16 -105 83 -414 -307 133 -6 298 -83 -39 -231 -69 23 453 -144 -4 -356 -51 200 124 -265 157 -255 -268 66 -43 -23 63 -114 -90 -227 -187 -20 287 -63 92 35 -147 -513 168 -301 -23 -259 309 -63 120 241 265 -151 -88 -38 12 106 152 86 -234 391 -299 -110 -122 -80 65 50 -82 -124 95 264 223 313 -63 611 106 -120 -167 -580 -425 88 -2 -2 210 172 52 87 317 -214 40 328 -132 -302 -98 -68 -292 -225 -43 293 193 -3 306 21 210 -190 -103 108 267 686 -24 37 164 -74 -157 -167 -349 -86 57 126 -165 273 28 224 -150 -281 14 -69 -325 307 139 29 -127 -27 -77 -109 243 -8 191 -221 -276 -44 188 248 -78 128 143 23 -5 230 -91 73 7 136 -219 62 -34 -256 114 92 -78 -86 -154 244 -154 140 -117 468 -122 -131 -320 -325 32 -206 248 296 228 -354 472 359 289 7 -338 -346 -133 -159 286 83 -4 304 129 0 -95 -11 -60 375 -516 31 188 -493 357 -136 191 231 -144 54 100 -177 -160 -46 -120 -95 -174 -122 -222 -356 -317 -27 248 139 226 -142 103 -76 43 -356 -18 511 -127 297 48 -251 -211 105 -289 370 -2 -163 467 -72 80 309 379 -22 -32 120 104 -155 -67 -233 -436 87 285 -307