File name: Pandora212s1_Pontianak_20240610_L2Fit_fout2c1d20220101p1-8.txt File generation date: 20240610T164639.4Z Data description: Level 2 spectral fitting results file Data file version: fout2c1p1-8 Local principal investigator: La Ode Muhammad Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 212 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora212_OF_v2d20210908.txt Instrument calibration file used: Pandora212s1_CF_v1d20220101.txt Level 1 file used: Pandora212s1_Pontianak_20240610_L1_smca1c1d20220101p1-8.txt Full location name: Pontianak Space and Atmosphere Observatory (Balai Pengamatan Antariksa dan Atmos Short location name: Pontianak Country of location: Indonesia Location latitude [deg]: 0.0415 Location longitude [deg]: 109.3366 Location altitude [m]: 1 Local noon date: 20240610 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 251 392 Nominal wavelengths inside fitting window [nm]: 305.0928 305.2340 305.3752 305.5163 305.6575 305.7986 305.9397 306.0808 306.2219 306.3630 306.5041 306.6451 306.7862 306.9272 307.0683 307.2093 307.3503 307.4913 307.6323 307.7732 307.9142 308.0551 308.1961 308.3370 308.4779 308.6188 308.7597 308.9006 309.0415 309.1823 309.3232 309.4640 309.6048 309.7457 309.8865 310.0273 310.1680 310.3088 310.4496 310.5903 310.7310 310.8718 311.0125 311.1532 311.2939 311.4345 311.5752 311.7159 311.8565 311.9971 312.1378 312.2784 312.4190 312.5596 312.7001 312.8407 312.9813 313.1218 313.2623 313.4028 313.5434 313.6838 313.8243 313.9648 314.1053 314.2457 314.3862 314.5266 314.6670 314.8074 314.9478 315.0882 315.2285 315.3689 315.5092 315.6496 315.7899 315.9302 316.0705 316.2108 316.3511 316.4913 316.6316 316.7718 316.9121 317.0523 317.1925 317.3327 317.4729 317.6131 317.7532 317.8934 318.0335 318.1736 318.3137 318.4539 318.5939 318.7340 318.8741 319.0142 319.1542 319.2942 319.4343 319.5743 319.7143 319.8542 319.9942 320.1342 320.2741 320.4141 320.5540 320.6939 320.8338 320.9737 321.1136 321.2535 321.3933 321.5332 321.6730 321.8128 321.9527 322.0925 322.2322 322.3720 322.5118 322.6515 322.7913 322.9310 323.0707 323.2104 323.3501 323.4898 323.6295 323.7691 323.9088 324.0484 324.1880 324.3277 324.4673 324.6068 324.7464 324.8860 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Ozone effective temperature [K] Column 28: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Sulfur dioxide effective temperature [K] Column 39: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 45: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 46: Lower limit used for wavelength scaling [nm] Column 47: Upper limit used for wavelength scaling [nm] Column 48: Order of smoothing polynomial Column 49: Smoothing polynomial coefficient, order 0 Column 50: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 51: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 52: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 53: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 54: Smoothing polynomial coefficient, order 1 Column 55: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 56: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 57: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 58: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 59: Smoothing polynomial coefficient, order 2 Column 60: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 61: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 62: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 63: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 64: Smoothing polynomial coefficient, order 3 Column 65: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 66: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 67: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 68: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 69: Mean value of measured data inside fitting window [same units as measurements] Column 70: Wavelength change polynomial coefficient, order 0 Column 71: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 72: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 76: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 77: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 78: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 80: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 81: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 83: Atmospheric variability [%], 999=no atmospheric variability was determined Column 84: Wavelength effective temperature [°C], 999=no effective temperature given Column 85: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 86: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 87: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 88: Number of bright count cycles Column 89: Number of dark count cycles Column 90: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 91: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 92: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 93: Integration time [ms] Column 94: Temperature at electronics board [°C], 999=no temperature signal Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Humidity in head sensor [%], -9=no humidity signal Column 99: Pressure in head sensor [hPa], -9=no pressure signal Columns 100-241: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 242-383: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------