File name: Pandora53s1_Potchefstroom-METSI_20230727_L2Fit_fsus1c2d20230223p1-8.txt File generation date: 20240824T145823.7Z Data description: Level 2 spectral fitting results file Data file version: fsus1c2p1-8 Local principal investigator: Stuart Piketh Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 53 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora53_OF_v5d20210210.txt Instrument calibration file used: Pandora53s1_CF_v2d20230223.txt Level 1 file used: Pandora53s1_Potchefstroom-METSI_20230727_L1_smca1c2d20230223p1-8.txt Full location name: Gerhard Minnebron Mooi River Ecosystem Trails for Scientific Investigations Short location name: Potchefstroom-METSI Country of location: South Africa Location latitude [deg]: -26.4907 Location longitude [deg]: 27.1322 Location altitude [m]: 1440 Local noon date: 20230727 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: Modification of session 103 "redoing cal analysis" First and last pixel inside fitting window: 266 411 Nominal wavelengths inside fitting window [nm]: 306.0297 306.1702 306.3108 306.4513 306.5919 306.7324 306.8729 307.0134 307.1539 307.2943 307.4348 307.5752 307.7157 307.8561 307.9965 308.1369 308.2773 308.4177 308.5581 308.6984 308.8388 308.9791 309.1194 309.2597 309.4000 309.5403 309.6806 309.8209 309.9611 310.1014 310.2416 310.3818 310.5220 310.6622 310.8024 310.9426 311.0827 311.2229 311.3630 311.5031 311.6433 311.7834 311.9234 312.0635 312.2036 312.3437 312.4837 312.6237 312.7638 312.9038 313.0438 313.1837 313.3237 313.4637 313.6036 313.7436 313.8835 314.0234 314.1633 314.3032 314.4431 314.5830 314.7228 314.8627 315.0025 315.1424 315.2822 315.4220 315.5618 315.7015 315.8413 315.9811 316.1208 316.2605 316.4002 316.5400 316.6797 316.8193 316.9590 317.0987 317.2383 317.3780 317.5176 317.6572 317.7968 317.9364 318.0760 318.2155 318.3551 318.4946 318.6342 318.7737 318.9132 319.0527 319.1922 319.3317 319.4711 319.6106 319.7500 319.8894 320.0288 320.1683 320.3076 320.4470 320.5864 320.7257 320.8651 321.0044 321.1437 321.2831 321.4224 321.5616 321.7009 321.8402 321.9794 322.1187 322.2579 322.3971 322.5363 322.6755 322.8147 322.9538 323.0930 323.2321 323.3713 323.5104 323.6495 323.7886 323.9277 324.0668 324.2058 324.3449 324.4839 324.6229 324.7620 324.9010 325.0399 325.1789 325.3179 325.4568 325.5958 325.7347 325.8736 326.0125 326.1514 326.2903 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Azimuth motor temperature [°C], 999=no temperature signal Column 159: Humidity in head sensor [%], -9=no humidity signal Column 160: Pressure in head sensor [hPa], -9=no pressure signal Columns 161-306: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 307-452: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20230727T140950.6Z 8608.590169 5 1 50.44 2 72.42 302.88 43.62 92.90 0.00 1 0.00 1 0 49 2.846e-03 6.020e-04 1.292e-03 3.024e-04 1.726644e-06 1.131393e-07 6.335410e-08 4.632861e-07 1.322592e-06 226.09 -2.00 3.06 -2.00 322.07 0.00e+00 1.091943e-04 4.274767e-05 3.183261e-05 3.784520e-05 3.386246e-04 278.98 -2.00 20.00 -2.00 321.97 0.00e+00 7.564330e-04 5.598831e-05 1.026258e-05 3.246298e-05 6.313440e-04 278.98 -2.00 20.00 -2.00 321.85 0.00e+00 -9.419837e-05 9.206952e-05 5.582713e-05 1.628560e-05 6.373250e-04 278.98 -2.00 20.00 -2.00 321.93 0.00e+00 4.008523e-01 5.064023e-04 1.791841e-04 1.885278e-03 3.804732e-03 231.45 0.30 0.00 0.15 6.44 318.86 0.00e+00 1.324460e-04 3.302980e-05 4.018356e-05 3.174698e-05 9.548816e-05 278.98 -2.00 20.00 -2.00 317.85 0.00e+00 3.266 0.000 303.00 329.40 4 1.0556e+00 1.2623e-03 2.6850e-02 2.3620e-03 1.1629e-02 4.7201e-04 1.9074e-03 3.0648e-03 5.2058e-04 1.2557e-02 -1.8166e-02 9.9512e-04 2.7497e-04 4.2160e-04 6.7746e-03 5.5316e-03 5.5778e-04 3.1336e-04 1.7752e-04 2.7096e-03 8.9502e-04 3.3860e-04 6.0627e-05 1.1364e-04 2.0898e-03 1.0017e-02 -1.5204e-03 1.0217e-04 3.7755e-05 1.8497e-05 2.0432e-04 1.5852e-04 9.6915e-06 2.8593e-06 3.5289e-06 9.5468e-05 1.6538e-02 0.0000e+00 2.7169e-01 2.0889e-02 2.5383e-03 7.4111e-04 1.6526e-01 10 0 0 10 0 0 0.09 20.71 0.26 0.01654 0.01775 871 161 1 5 0 57.890 23.22 14.93 20.71 27.12 39.60 16.7 933.06 1313 87 543 663 735 755 853 1344 392 327 427 118 281 10 33 -242 219 -324 -4 -258 -796 -683 -742 -194 -23 26 -385 -610 -737 -536 -299 -119 -9 69 179 122 117 76 258 64 -34 -224 -121 -19 109 76 51 224 12 23 -10 -5 -191 -124 57 25 55 135 104 5 36 45 62 15 45 1 -64 -8 68 125 -56 -109 37 46 9 -43 -74 -104 -62 -53 -43 -84 13 64 48 83 2 41 18 -56 46 28 19 -14 -74 -24 47 1 -57 -18 -23 38 32 0 -45 -35 -36 -23 35 85 68 -22 -3 -5 -39 31 75 14 -4 24 -13 20 -36 -57 22 -50 -3 14 4 17 9 40 9 -9 -41 -16 -25 -15 -12 1 5 57 12 -7 14 -39 70 5 35 45 53 62 75 137 46 41 57 17 41 2 5 -39 37 -54 -1 -46 -137 -122 -134 -35 -4 6 -89 -140 -170 -134 -80 -38 -3 27 74 52 48 31 107 27 -15 -93 -52 -9 53 37 27 124 7 13 -6 -3 -110 -73 34 16 37 92 68 3 24 30 46 12 35 1 -50 -6 48 86 -37 -73 28 37 8 -38 -67 -101 -61 -55 -46 -90 14 64 45 75 2 39 18 -58 51 33 23 -17 -82 -26 52 1 -65 -21 -28 48 43 0 -61 -47 -49 -30 44 106 85 -29 -5 -7 -53 40 99 18 -5 29 -16 25 -48 -79 31 -72 -4 20 6 27 15 66 15 -14 -62 -24 -38 -24 -19 1 9 106 23 -14 29 -77 SS 20230727T141533.6Z 8608.594138 8 1 50.51 2 73.50 302.04 42.36 92.37 0.00 1 0.00 1 0 49 3.245e-03 6.634e-04 1.678e-03 3.299e-04 2.234110e-06 1.228464e-07 7.738374e-08 4.633433e-07 1.504237e-06 226.09 -2.00 3.06 -2.00 322.22 0.00e+00 9.957944e-05 4.701189e-05 3.715409e-05 3.813054e-05 3.855505e-04 278.98 -2.00 20.00 -2.00 322.15 0.00e+00 8.968648e-04 6.133673e-05 1.279693e-05 3.244993e-05 7.225548e-04 278.98 -2.00 20.00 -2.00 321.96 0.00e+00 -2.063846e-04 1.039825e-04 6.628460e-05 1.534743e-05 7.267222e-04 278.98 -2.00 20.00 -2.00 322.06 0.00e+00 4.231957e-01 5.670864e-04 2.401600e-04 1.885205e-03 4.345776e-03 231.72 0.31 0.00 0.15 7.34 319.13 0.00e+00 1.381438e-04 3.915085e-05 6.855202e-05 3.177207e-05 1.091946e-04 278.98 -2.00 20.00 -2.00 318.12 0.00e+00 3.466 0.000 303.00 329.40 4 1.0362e+00 1.3951e-03 2.8498e-02 2.3627e-03 1.3269e-02 4.1744e-03 2.1501e-03 3.4899e-03 5.1174e-04 1.4316e-02 -2.0400e-02 1.1200e-03 3.3315e-04 4.3716e-04 7.7291e-03 4.9541e-03 6.5608e-04 3.6120e-04 2.1307e-04 3.0829e-03 1.9666e-03 3.9000e-04 4.4976e-05 1.1086e-04 2.4246e-03 8.4913e-03 -1.5676e-03 1.0348e-04 4.4545e-05 2.0997e-05 1.9057e-04 3.3979e-04 1.0623e-05 2.8726e-06 3.5599e-06 1.0894e-04 1.8711e-02 0.0000e+00 2.9494e-02 2.2005e-02 3.2547e-03 7.4962e-04 1.8148e-01 10 0 0 10 0 0 -13.08 20.08 0.25 0.01871 0.02130 793 147 1 5 0 63.600 22.71 15.00 20.08 28.05 44.40 16.1 935.14 978 -595 273 -12 625 791 271 1945 67 1036 705 390 725 -348 513 -197 488 -61 10 -126 -333 -307 -820 192 -376 -266 -870 -723 -911 -688 -447 -327 -116 -20 128 56 178 182 152 101 11 -53 -29 46 -106 130 73 183 186 16 63 -19 -136 -257 -32 42 6 95 147 92 56 166 -37 -18 13 48 -123 -70 34 -22 -64 -48 22 6 5 -30 8 19 -119 -70 -34 -91 -26 103 91 106 148 25 33 -39 -10 -10 19 -23 -41 27 -2 17 14 3 -81 -11 32 -11 -46 -62 -14 -54 -2 73 81 35 -48 18 -54 81 65 26 -18 -10 -23 27 -17 -102 10 -38 31 35 -17 47 18 19 -13 -16 -25 -33 18 -9 0 0 23 17 26 -31 9 -24 42 -29 14 -1 37 53 22 163 7 109 79 46 90 -45 66 -27 70 -9 2 -20 -53 -47 -128 32 -65 -51 -177 -145 -185 -152 -114 -93 -38 -7 47 22 69 71 60 40 5 -21 -12 20 -47 62 38 93 98 9 34 -10 -71 -140 -18 25 4 63 95 57 35 110 -26 -13 10 37 -91 -51 23 -14 -40 -32 16 5 4 -27 7 19 -118 -73 -34 -93 -27 99 85 98 134 23 33 -41 -11 -12 22 -27 -44 29 -2 19 16 3 -100 -14 42 -15 -65 -86 -18 -68 -3 90 104 45 -66 24 -73 109 84 33 -23 -12 -28 34 -23 -141 15 -55 46 55 -27 75 29 31 -21 -25 -40 -51 28 -15 1 1 43 33 50 -62 17 -49 SS 20230727T142056.2Z 8608.597873 11 1 50.50 2 74.52 301.25 41.18 91.87 0.00 1 0.00 1 0 49 4.674e-03 7.465e-04 2.334e-03 3.710e-04 2.326392e-06 1.378223e-07 9.498402e-08 4.634204e-07 2.161993e-06 226.09 -2.00 3.06 -2.00 322.36 0.00e+00 1.640981e-04 5.347990e-05 4.579525e-05 3.850089e-05 5.547542e-04 278.98 -2.00 20.00 -2.00 322.35 0.00e+00 1.007223e-03 6.930183e-05 1.875404e-05 3.236774e-05 1.043289e-03 278.98 -2.00 20.00 -2.00 322.07 0.00e+00 -8.218680e-05 1.222669e-04 1.225667e-04 1.335314e-05 1.046654e-03 278.98 -2.00 20.00 -2.00 322.20 0.00e+00 4.473991e-01 6.588509e-04 4.778409e-04 1.884850e-03 6.271399e-03 231.81 0.34 0.00 0.14 10.57 319.42 0.00e+00 1.258782e-04 4.836565e-05 1.431578e-04 3.161734e-05 1.579610e-04 278.98 -2.00 20.00 -2.00 318.42 0.00e+00 3.681 0.000 303.00 329.40 4 1.0703e+00 1.5888e-03 3.0280e-02 2.3641e-03 1.9126e-02 4.7667e-03 2.5192e-03 4.6802e-03 4.8298e-04 2.0617e-02 -2.0325e-02 1.3072e-03 8.4799e-04 4.4576e-04 1.1143e-02 4.1474e-03 8.0481e-04 3.5655e-04 2.5702e-04 4.4601e-03 2.2549e-03 4.6689e-04 4.9513e-05 1.0950e-04 3.5622e-03 6.7220e-03 -1.5948e-03 1.0923e-04 5.3867e-05 2.3397e-05 2.2768e-04 4.8889e-04 1.2038e-05 2.7049e-06 3.4882e-06 1.5695e-04 1.9547e-02 0.0000e+00 -5.4629e-02 2.3904e-02 4.7529e-03 7.3740e-04 2.5181e-01 10 0 0 10 0 0 -11.09 19.53 0.26 0.01955 0.02328 694 128 1 5 0 72.750 22.29 15.02 19.53 28.55 46.60 15.8 936.09 -1942 -2971 -1162 -1584 805 -481 1227 750 972 482 621 703 554 523 152 1709 286 249 35 168 -11 -448 -223 -423 254 20 -482 -422 -929 -629 -573 109 -343 55 -118 161 161 41 122 -46 61 -351 156 -99 44 101 -91 80 7 215 -85 -25 -269 -52 54 -66 -10 -12 216 -47 103 33 45 -24 -57 66 -60 36 -201 77 -19 61 141 -131 79 -17 50 -74 -60 -55 36 -110 59 68 127 196 83 108 91 -71 -24 12 30 -38 -5 -18 17 -26 -32 -43 -65 74 -14 -22 -133 -44 -49 -85 111 66 44 -34 2 -35 -102 -4 88 69 12 44 32 -17 -13 -69 11 -76 26 33 34 92 -16 32 43 -35 -67 -20 -17 56 -41 50 -21 -13 60 -43 5 -25 -66 -113 -47 -68 37 -26 76 55 81 44 61 67 55 53 16 183 33 31 5 22 -1 -56 -28 -59 40 3 -89 -77 -173 -127 -124 28 -97 17 -40 57 58 15 45 -17 22 -131 60 -38 19 46 -41 38 3 109 -43 -12 -134 -27 30 -38 -6 -8 133 -28 62 21 31 -17 -43 49 -43 25 -128 48 -12 40 98 -99 64 -15 44 -71 -58 -56 37 -110 60 64 116 176 74 98 88 -75 -27 14 35 -44 -5 -18 18 -29 -36 -49 -78 92 -18 -30 -185 -61 -66 -112 139 81 56 -45 2 -49 -141 -5 117 87 15 53 39 -22 -17 -97 16 -113 39 53 55 152 -26 53 72 -55 -106 -30 -27 91 -70 90 -38 -24 119 -89 11 -51 SS 20230727T142642.7Z 8608.601884 14 1 50.47 2 75.63 300.43 39.92 91.31 0.00 1 0.00 1 0 49 7.966e-03 7.721e-04 3.507e-03 4.379e-04 2.719643e-06 1.621361e-07 8.657983e-08 4.635087e-07 3.676228e-06 226.09 -2.00 3.06 -2.00 322.54 0.00e+00 2.827914e-04 6.406653e-05 3.710441e-05 3.890363e-05 9.447116e-04 278.98 -2.00 20.00 -2.00 322.63 0.00e+00 9.937526e-04 8.275656e-05 2.169556e-05 3.222903e-05 1.783434e-03 278.98 -2.00 20.00 -2.00 322.21 0.00e+00 2.924039e-04 1.530853e-04 1.568332e-04 1.141467e-05 1.783695e-03 278.98 -2.00 20.00 -2.00 322.38 0.00e+00 4.745486e-01 8.098609e-04 5.976835e-04 1.884265e-03 1.070631e-02 230.62 0.39 0.00 0.13 17.99 319.77 0.00e+00 -2.911864e-05 6.415794e-05 1.836061e-04 3.130105e-05 2.695125e-04 278.98 -2.00 20.00 -2.00 318.78 0.00e+00 3.947 0.000 303.00 329.40 4 1.1534e+00 1.8787e-03 3.2477e-02 2.3650e-03 3.2604e-02 -4.4006e-03 3.1048e-03 5.3688e-03 4.4667e-04 3.5125e-02 -1.5958e-02 1.6092e-03 1.2587e-03 4.5413e-04 1.9016e-02 7.6991e-04 1.0387e-03 2.4868e-04 3.1121e-04 7.6147e-03 3.2221e-03 5.8899e-04 8.1386e-05 1.1319e-04 6.1925e-03 4.8769e-03 -1.8031e-03 1.1654e-04 4.5964e-05 2.4636e-05 3.0785e-04 5.4512e-04 1.4376e-05 3.4866e-06 3.4119e-06 2.6766e-04 2.0268e-02 0.0000e+00 -1.7792e-01 2.7034e-02 4.8856e-03 7.3361e-04 4.0966e-01 10 0 0 10 0 0 -6.39 19.21 0.24 0.02027 0.02443 581 107 1 5 0 86.850 21.98 15.00 19.21 28.79 49.10 15.7 937.04 -4687 -2807 -3621 -1035 -3821 1925 -1349 2005 376 768 1413 941 1778 -119 1101 376 762 88 -151 758 9 648 -46 1117 293 590 -438 -612 -696 -958 -361 -679 -246 -55 134 -48 130 -112 -66 103 -175 -219 -272 -65 -161 41 87 98 270 53 130 -27 -204 -164 -38 91 -60 124 69 45 89 109 113 -23 -1 30 -156 -65 -87 -62 -147 145 92 -9 -84 152 -29 -29 -67 -109 58 -92 93 56 122 192 116 118 -3 23 -90 -33 -60 -14 37 91 96 -29 24 -103 -57 11 17 3 -139 -45 -54 -9 13 54 93 7 -18 -65 -125 -23 105 80 64 -6 32 -18 11 -60 -24 -55 59 57 -43 60 -5 38 29 -16 -58 20 -13 5 12 -7 1 20 29 -54 -6 1 -134 -80 -112 -33 -137 76 -65 111 24 54 106 75 148 -10 96 35 69 9 -16 79 1 64 -5 125 37 83 -66 -92 -106 -160 -70 -147 -63 -16 38 -14 39 -34 -20 32 -54 -70 -90 -23 -63 16 37 43 124 25 62 -13 -95 -78 -18 48 -35 70 40 26 51 63 73 -15 -1 21 -106 -43 -53 -37 -87 86 62 -7 -66 130 -25 -27 -63 -107 58 -92 90 51 107 161 96 105 -3 24 -100 -38 -69 -16 41 93 99 -32 26 -122 -68 14 22 4 -192 -61 -74 -12 17 68 120 10 -25 -92 -173 -31 140 102 78 -8 40 -23 15 -85 -35 -82 90 92 -71 102 -8 65 48 -26 -92 31 -21 8 21 -12 3 40 59 -112 -12 1 SS 20230727T143733.6Z 8608.609416 17 1 50.57 2 77.74 298.94 37.53 90.24 0.00 1 0.00 1 0 49 1.176e-02 9.463e-04 9.106e-03 6.601e-04 3.782501e-06 2.442525e-07 1.470375e-07 4.638468e-07 5.386889e-06 226.09 -2.00 3.06 -2.00 322.95 0.00e+00 2.795919e-04 1.004030e-04 4.593430e-05 3.991796e-05 1.394138e-03 278.98 -2.00 20.00 -2.00 323.24 0.00e+00 1.098339e-03 1.292043e-04 4.025923e-05 3.178480e-05 2.635096e-03 278.98 -2.00 20.00 -2.00 322.53 0.00e+00 5.324831e-05 2.627771e-04 3.297856e-04 9.221747e-06 2.634386e-03 278.98 -2.00 20.00 -2.00 322.77 0.00e+00 5.457678e-01 1.349249e-03 1.263537e-03 1.882977e-03 1.586756e-02 231.32 0.57 0.00 0.11 26.37 320.56 0.00e+00 -5.322676e-05 1.262173e-04 4.367144e-04 3.083556e-05 4.069050e-04 278.98 -2.00 20.00 -2.00 319.59 0.00e+00 4.577 0.001 303.00 329.40 4 1.3640e+00 2.9862e-03 3.7716e-02 2.3662e-03 4.8167e-02 1.0358e-03 5.2902e-03 9.8203e-03 3.6145e-04 5.1802e-02 -1.4570e-02 2.7274e-03 2.7722e-03 4.7914e-04 2.8185e-02 -8.4834e-03 1.8794e-03 7.1688e-04 4.5693e-04 1.1329e-02 7.7147e-03 1.0235e-03 3.9265e-04 1.5143e-04 9.4847e-03 2.2423e-03 -2.7777e-03 1.2720e-04 8.9385e-05 2.4897e-05 2.8233e-04 6.5888e-04 2.2648e-05 8.3773e-06 3.0469e-06 3.9485e-04 2.0437e-02 0.0000e+00 -1.8886e-01 3.7102e-02 9.5257e-03 8.2910e-04 5.4779e-01 10 0 0 10 0 0 2.39 18.78 0.25 0.02044 0.02546 371 69 1 5 0 136.280 21.69 15.01 18.78 28.94 51.90 15.6 936.98 -8579 -5663 3780 3473 -898 -2597 1874 1820 -3582 218 745 588 -835 -912 -866 1251 -271 422 1510 -170 1917 604 792 1261 1261 -125 -1292 -828 -24 -47 -187 1149 -194 120 503 234 496 -389 238 -586 -111 -213 -294 -101 -118 43 -152 292 -130 153 116 -164 -411 -307 -173 -102 148 -137 367 166 256 168 195 -135 -106 21 -361 -137 -322 120 -433 -117 88 29 -52 33 115 -52 -50 38 -35 22 57 123 89 216 106 91 87 -24 -18 -7 109 133 -91 81 0 6 28 5 -68 25 58 -57 -159 -24 -113 -82 95 84 -5 -95 -90 -48 -127 38 89 113 43 -12 -2 -24 13 -156 39 -45 90 18 -7 135 -53 10 77 -52 -39 63 -22 -2 -7 68 -72 31 59 -66 10 -32 -137 -97 65 63 -19 -63 52 54 -127 8 31 26 -39 -44 -43 64 -15 25 95 -11 119 38 52 92 105 -12 -133 -85 -2 -5 -23 166 -34 24 105 48 103 -83 51 -128 -25 -49 -71 -27 -34 14 -48 98 -46 55 42 -59 -146 -112 -68 -45 67 -64 169 76 119 85 111 -79 -66 13 -213 -79 -170 59 -213 -62 51 19 -37 26 90 -43 -44 34 -31 20 49 105 72 175 82 77 78 -23 -20 -8 124 144 -95 79 0 7 31 6 -80 30 73 -78 -218 -33 -156 -106 123 108 -6 -128 -123 -65 -178 52 116 146 54 -15 -3 -30 18 -232 59 -72 145 29 -12 231 -92 18 136 -87 -65 102 -37 -4 -13 130 -144 66 129 -144 23 -72 SS 20230727T150116.4Z 8608.625884 23 1 50.77 2 82.45 295.86 32.32 87.67 0.00 1 0.00 1 0 98 2.306e-01 8.377e-03 1.382e-01 3.486e-03 8.314926e-06 1.416769e-06 6.527061e-07 4.644410e-07 1.003030e-04 226.09 -2.00 3.06 -2.00 323.99 0.00e+00 2.783062e-03 6.786274e-04 1.854573e-04 4.168173e-05 2.737995e-02 278.98 -2.00 20.00 -2.00 324.77 0.00e+00 2.005037e-03 8.763971e-04 6.073991e-04 3.168054e-05 4.936117e-02 278.98 -2.00 20.00 -2.00 323.41 0.00e+00 7.540501e-03 2.116904e-03 1.344342e-03 1.454558e-05 5.159981e-02 278.98 -2.00 20.00 -2.00 323.81 0.00e+00 7.750723e-01 9.515834e-03 3.034940e-03 1.881731e-03 3.136631e-01 227.07 2.74 0.00 0.09 509.21 322.48 0.00e+00 -2.898035e-03 1.451538e-03 3.691451e-03 3.038734e-05 7.556153e-03 278.98 -2.00 20.00 -2.00 321.66 0.00e+00 7.076 0.002 303.00 329.40 4 2.1226e+00 1.8356e-02 6.0637e-02 2.3648e-03 9.4378e-01 3.9884e-02 3.8009e-02 4.7014e-02 3.9909e-04 1.0175e+00 -3.4664e-01 2.6594e-02 1.6313e-02 4.2732e-04 5.5644e-01 4.0615e-01 2.2411e-02 5.9125e-03 4.5005e-04 1.8563e-01 -1.5681e-01 9.4571e-03 3.8627e-03 1.5397e-04 1.3289e-01 1.1362e-04 1.3962e-02 1.6369e-03 2.3400e-08 1.0039e-09 2.4189e-07 1.3890e-03 1.4733e-04 4.1091e-05 3.1108e-06 7.7583e-03 2.0786e-02 0.0000e+00 -1.1447e-01 1.4807e-01 4.6090e-02 1.1066e-03 7.6477e+00 12 8 8 10 0 0 -20.70 18.42 0.49 0.02079 0.03138 60 11 1 5 0 845.940 21.38 14.97 18.42 28.22 53.60 15.5 931.76 -104983 -95018 -60795 -65528 -46908 -34634 124309 -10708 -83145 -21937 -7425 -10666 -2898 -30986 -26397 50064 -43435 -34598 -8559 7578 -8200 -26877 -11696 1670 37528 3953 -23097 -21601 -8908 -8255 -20404 19165 -3053 14362 13920 18335 21857 -6150 16170 -2257 13834 1400 16075 11324 4975 10808 12501 8699 3746 11230 13830 8678 -2936 282 5102 -3162 7089 1231 7419 -834 4276 1691 1734 -1127 -4864 -1576 -2131 2677 -3598 19 -15418 -1840 2403 -237 2350 -1541 -791 -2577 231 -112 -1567 -1998 -683 -447 -1875 1954 -1230 2203 -982 -315 694 -189 918 -688 -701 -393 668 -590 299 651 -405 495 372 816 145 -7 65 -185 296 172 471 272 882 243 -349 223 283 496 -255 -88 128 -50 10 -19 208 -628 -309 -860 144 100 112 -104 -102 -8 44 243 -5 -458 -105 -194 -115 210 447 -442 84 247 -1261 -1112 -542 -610 -434 -343 410 -124 -2396 -349 -107 -166 -42 -614 -491 413 -1121 -872 -167 133 -162 -581 -251 36 644 104 -874 -791 -286 -290 -968 731 -177 785 819 1068 1233 -463 971 -167 901 110 1177 972 511 1155 1321 1027 491 1403 1674 1072 -398 38 713 -545 1240 244 1398 -174 893 402 469 -319 -1500 -465 -597 706 -919 4 -4399 -520 716 -86 958 -726 -396 -1399 129 -61 -880 -1121 -363 -240 -974 965 -661 1202 -647 -242 565 -169 826 -598 -557 -305 507 -480 256 550 -373 498 396 964 186 -9 84 -228 352 206 585 356 1185 325 -452 276 337 566 -284 -96 146 -64 13 -30 327 -1064 -558 -1582 276 198 225 -209 -196 -14 80 419 -10 -844 -214 -417 -261 524 1149 -1214 226 680