File name: Pandora181s1_SanJoseCA_20240413_L2Fit_fwvt1c42d20221001p1-8.txt File generation date: 20240414T081340.7Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c42p1-8 Local principal investigator: Sen Chiao Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 181 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora181_OF_v2d20200716.txt Instrument calibration file used: Pandora181s1_CF_v42d20221001.txt Level 1 file used: Pandora181s1_SanJoseCA_20240413_L1_smca1c42d20221001p1-8.txt Full location name: San Jose State University, Duncan Hall Short location name: SanJoseCA Country of location: United States Location latitude [deg]: 37.3325 Location longitude [deg]: -121.8821 Location altitude [m]: 69 Local noon date: 20240413 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, radiometric temperature correction, matrix method stray light correction (replaced by simple method) Data caveats: 3rd VP based on Session 4, refday:20230621 First and last pixel inside fitting window: 1629 1778 Nominal wavelengths inside fitting window [nm]: 492.0858 492.2070 492.3283 492.4495 492.5707 492.6919 492.8131 492.9343 493.0554 493.1765 493.2976 493.4187 493.5398 493.6609 493.7819 493.9029 494.0239 494.1449 494.2659 494.3869 494.5078 494.6287 494.7496 494.8705 494.9914 495.1123 495.2331 495.3539 495.4747 495.5955 495.7163 495.8370 495.9578 496.0785 496.1992 496.3199 496.4406 496.5612 496.6819 496.8025 496.9231 497.0437 497.1642 497.2848 497.4053 497.5258 497.6463 497.7668 497.8873 498.0077 498.1282 498.2486 498.3690 498.4894 498.6097 498.7301 498.8504 498.9707 499.0910 499.2113 499.3316 499.4518 499.5720 499.6923 499.8124 499.9326 500.0528 500.1729 500.2931 500.4132 500.5333 500.6533 500.7734 500.8934 501.0134 501.1335 501.2534 501.3734 501.4934 501.6133 501.7332 501.8531 501.9730 502.0929 502.2127 502.3326 502.4524 502.5722 502.6920 502.8117 502.9315 503.0512 503.1709 503.2906 503.4103 503.5300 503.6496 503.7693 503.8889 504.0085 504.1280 504.2476 504.3672 504.4867 504.6062 504.7257 504.8452 504.9646 505.0841 505.2035 505.3229 505.4423 505.5616 505.6810 505.8003 505.9197 506.0390 506.1582 506.2775 506.3968 506.5160 506.6352 506.7544 506.8736 506.9928 507.1119 507.2310 507.3501 507.4692 507.5883 507.7074 507.8264 507.9455 508.0645 508.1835 508.3024 508.4214 508.5403 508.6592 508.7782 508.8970 509.0159 509.1348 509.2536 509.3724 509.4912 509.6100 509.7288 509.8475 509.9663 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Temperature at electronics board [°C], 999=no temperature signal Column 96: Spectrometer control temperature [°C], 999=no temperature signal Column 97: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 98: Temperature in head sensor [°C], 999=no temperature signal Column 99: Humidity in head sensor [%], -9=no humidity signal Column 100: Pressure in head sensor [hPa], -9=no pressure signal Columns 101-250: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 251-400: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20240414T003220.5Z 8870.022460 438 1 49.44 2 65.32 263.01 9.99 151.44 0.00 1 0.00 1 0 15 4.738e-03 4.711e-03 1.334e-03 1.329e-03 2.230395e+03 7.588803e+01 1.841549e+02 -6.000000e+00 2.494048e+02 282.37 -2.00 20.00 -2.00 505.24 0.00e+00 4.590788e-04 3.569683e-05 2.526012e-05 -6.000000e+00 1.301749e-04 282.37 -2.00 20.00 -2.00 500.30 0.00e+00 3.950808e-01 2.576509e-02 1.205564e-02 -6.000000e+00 9.136648e-02 228.93 -2.00 3.44 -2.00 501.91 0.00e+00 2.379 0.000 489.00 513.00 1 7.9144e+00 1.9711e-03 3.6101e-03 -6.0000e+00 6.9875e-03 8.2204e-03 5.1729e-04 3.8330e-04 -6.0000e+00 1.8345e-03 4.9179e-04 6.9567e-04 1.0577e-04 2.2635e-05 -6.0000e+00 3.8825e-04 1.4891e-02 2.8706e-05 12 8 8 10 0 0 99.97 21.83 1.95 0.01489 0.01972 25 6 1 4 0 1977.140 25.39 20.00 21.83 16.48 26.8 978.22 -712 -343 152 80 -128 622 437 341 567 -84 50 -20 -537 -292 -583 -1062 -152 -66 501 582 82 184 -72 499 309 699 642 361 -536 -62 -1581 -893 -107 476 257 565 245 -71 -144 -301 73 -221 441 443 713 614 574 210 -12 -688 -569 -1025 -1278 -772 -690 252 35 181 -11 340 -21 18 377 266 132 419 325 171 229 -257 -272 -261 -206 -72 71 -486 -212 -834 -619 -417 33 -420 -80 145 102 30 37 60 334 -145 465 510 764 336 697 360 -120 115 -933 -1059 -1262 -147 -9 196 -80 24 -539 -650 -668 -86 -15 145 483 156 394 750 454 349 214 22 -505 -551 129 63 234 481 238 675 818 -160 197 -176 -526 -20 25 -356 -241 -63 -192 200 524 350 734 387 330 -322 -250 -492 -651 -663 -701 -345 154 84 -137 655 469 368 605 -89 52 -21 -561 -300 -602 -1111 -161 -70 539 627 89 200 -78 540 337 757 692 385 -550 -63 -1587 -899 -110 510 274 594 263 -75 -151 -314 76 -234 456 463 749 644 595 215 -12 -694 -554 -1015 -1264 -753 -698 261 36 185 -12 343 -21 19 385 271 133 425 326 170 224 -248 -263 -255 -204 -72 69 -483 -205 -801 -588 -396 32 -408 -78 142 99 29 36 58 323 -142 456 511 773 338 685 349 -114 109 -869 -979 -1181 -140 -9 190 -79 23 -530 -628 -646 -84 -14 142 477 155 393 749 458 350 211 21 -485 -523 122 61 224 460 228 640 776 -153 183 -166 -494 -19 23 -332 -231 -60 -188 191 500 336 708 376 319 -308 -238 -458 -602 -619 SQ 20240414T014739.1Z 8870.074758 478 1 27.00 2 80.25 274.61 14.05 234.36 0.00 1 0.00 1 0 22 4.014e-03 3.974e-03 1.905e-04 1.900e-04 4.011849e+03 1.127266e+01 3.068935e+02 -6.000000e+00 2.113104e+02 282.38 -2.00 20.00 -2.00 505.27 0.00e+00 8.650118e-04 5.114545e-06 4.718848e-05 -6.000000e+00 1.102847e-04 282.38 -2.00 20.00 -2.00 500.41 0.00e+00 1.078757e+00 3.668756e-03 2.491461e-02 -6.000000e+00 7.741873e-02 228.93 -2.00 3.44 -2.00 502.01 0.00e+00 5.639 0.003 489.00 513.00 1 3.0505e+00 2.8054e-04 8.4143e-03 -6.0000e+00 5.9207e-03 2.3128e-03 7.3169e-05 7.7773e-04 -6.0000e+00 1.5547e-03 3.7770e-02 8.4239e-04 1.5019e-05 3.7757e-05 -6.0000e+00 3.2897e-04 1.6154e-02 1.3544e-05 11 8 0 10 0 0 99.99 21.80 1.92 0.01615 0.02200 556 129 1 4 0 48.270 25.39 20.00 21.80 16.48 26.8 977.69 -820 -471 -126 -32 248 482 509 532 149 204 76 -185 -535 -390 -385 -440 -248 174 173 221 273 168 179 320 391 423 636 94 -280 -273 -535 -815 -135 388 429 347 152 -159 -474 -466 -225 60 291 537 454 471 445 421 -48 -493 -643 -907 -817 -463 -267 2 252 168 97 7 92 256 342 376 254 78 59 -88 -332 -327 -265 -419 -173 82 126 -101 -234 -516 -651 -493 -260 -297 -188 73 174 33 40 34 51 23 281 729 657 603 630 446 -33 -476 -726 -785 -792 -726 -135 60 27 -61 -391 -570 -546 -210 -106 181 229 435 521 776 765 434 226 -4 -290 -301 -139 -34 203 417 389 299 574 197 35 -75 -367 -729 -380 -125 -130 -25 156 240 303 372 352 384 433 180 -276 -600 -738 -635 -802 -470 -129 -32 260 504 542 570 158 213 78 -190 -549 -395 -392 -451 -253 183 182 234 289 178 189 340 418 450 674 98 -288 -277 -534 -823 -140 409 453 364 161 -166 -492 -481 -233 62 300 561 478 494 462 440 -50 -492 -635 -880 -790 -456 -267 2 258 172 99 7 94 263 351 384 256 79 59 -87 -324 -321 -260 -408 -170 81 126 -99 -225 -501 -628 -475 -252 -286 -181 71 172 32 40 34 50 22 275 726 649 601 615 436 -32 -453 -675 -724 -738 -681 -129 59 27 -60 -385 -552 -528 -206 -104 179 229 429 514 770 767 434 223 -4 -283 -290 -135 -34 199 407 380 291 559 192 34 -71 -350 -691 -355 -120 -125 -24 154 235 296 366 349 382 429 176 -268 -570 -697 -605 SQ 20240414T014804.3Z 8870.075050 478 2 22.89 2 80.33 274.67 14.12 234.61 0.00 1 0.00 1 0 22 4.043e-03 4.007e-03 2.115e-04 2.109e-04 4.024231e+03 1.252696e+01 3.097265e+02 -6.000000e+00 2.128494e+02 282.38 -2.00 20.00 -2.00 505.27 0.00e+00 8.675178e-04 5.671236e-06 4.745990e-05 -6.000000e+00 1.110889e-04 282.38 -2.00 20.00 -2.00 500.41 0.00e+00 1.093106e+00 4.074359e-03 2.490115e-02 -6.000000e+00 7.798139e-02 228.93 -2.00 3.44 -2.00 502.01 0.00e+00 5.682 0.003 489.00 513.00 1 3.0817e+00 3.1145e-04 8.4750e-03 -6.0000e+00 5.9637e-03 2.6990e-03 8.1179e-05 7.8290e-04 -6.0000e+00 1.5659e-03 3.6341e-02 8.0568e-04 1.6679e-05 3.8254e-05 -6.0000e+00 3.3136e-04 1.6011e-02 1.5519e-05 12 9 1 12 1 1 99.99 21.80 1.92 0.01601 0.02160 471 129 1 4 0 48.270 25.39 20.00 21.80 16.51 26.8 977.69 -817 -503 -105 -12 270 498 553 498 160 189 58 -164 -488 -396 -407 -454 -255 184 159 242 248 157 192 319 394 448 639 105 -278 -301 -582 -811 -144 394 459 375 145 -152 -467 -408 -217 89 237 512 476 487 455 388 -61 -498 -674 -931 -877 -472 -265 -5 251 204 91 44 107 276 312 378 238 72 49 -82 -334 -341 -275 -398 -139 83 96 -129 -210 -542 -660 -543 -256 -350 -160 125 161 60 -1 100 86 19 262 698 690 609 647 420 34 -474 -722 -816 -822 -723 -121 4 36 -39 -400 -578 -560 -195 -90 115 249 421 545 758 763 449 208 -4 -274 -300 -113 -30 153 388 343 349 599 190 34 -68 -325 -694 -375 -92 -100 7 175 244 384 302 337 412 391 151 -299 -583 -741 -656 -806 -496 -106 -13 280 525 581 527 168 199 60 -170 -494 -404 -417 -460 -262 190 169 258 264 167 204 342 415 470 681 110 -288 -302 -585 -826 -146 410 489 395 151 -157 -488 -423 -227 92 246 538 504 514 476 400 -63 -500 -671 -910 -855 -468 -266 -5 258 210 93 45 109 286 323 389 242 72 49 -82 -329 -330 -266 -390 -138 81 94 -128 -203 -519 -627 -515 -246 -339 -155 122 157 58 -1 98 84 18 259 686 686 598 636 405 33 -444 -676 -758 -771 -683 -117 4 36 -39 -388 -562 -545 -189 -89 115 245 417 540 757 768 452 206 -4 -269 -291 -110 -29 148 373 330 341 574 182 32 -64 -306 -649 -353 -88 -97 7 171 240 378 299 336 412 390 148 -292 -557 -704 -629 SQ 20240414T015907.4Z 8870.082725 481 1 48.69 2 82.52 276.32 15.93 240.51 0.00 1 0.00 1 0 22 4.314e-03 4.277e-03 1.639e-04 1.636e-04 5.154987e+03 9.892686e+00 3.833951e+02 -6.000000e+00 2.271257e+02 282.38 -2.00 20.00 -2.00 505.29 0.00e+00 1.046784e-03 4.405950e-06 5.841934e-05 -6.000000e+00 1.185455e-04 282.38 -2.00 20.00 -2.00 500.48 0.00e+00 1.348277e+00 3.150208e-03 3.312974e-02 -6.000000e+00 8.320006e-02 228.93 -2.00 3.44 -2.00 502.07 0.00e+00 7.118 0.006 489.00 513.00 1 3.1450e+00 2.4077e-04 1.0671e-02 -6.0000e+00 6.3630e-03 -4.5445e-03 6.2595e-05 1.0065e-03 -6.0000e+00 1.6705e-03 2.7177e-02 7.2655e-04 1.2907e-05 4.7740e-05 -6.0000e+00 3.5355e-04 1.1219e-02 4.9219e-05 11 8 0 10 0 0 99.31 21.79 1.94 0.01122 0.01626 366 85 1 4 0 133.000 25.39 20.00 21.79 16.38 26.7 976.70 -871 -566 -130 -31 295 537 555 558 195 204 60 -221 -535 -465 -444 -468 -278 188 171 254 254 178 227 361 427 485 675 147 -328 -355 -599 -844 -130 397 504 397 157 -142 -486 -448 -251 81 314 567 484 485 491 409 -16 -519 -697 -989 -859 -485 -220 -4 289 191 128 28 140 332 380 432 251 129 22 -109 -354 -401 -314 -444 -168 83 115 -138 -246 -587 -757 -592 -287 -342 -211 69 129 46 11 13 63 29 273 715 690 663 647 450 -54 -527 -784 -838 -840 -749 -119 45 61 -27 -413 -616 -582 -205 -85 160 293 449 631 877 839 503 247 23 -279 -332 -90 -44 222 455 353 337 603 192 7 -80 -364 -724 -404 -122 -94 4 151 285 292 367 377 404 433 152 -355 -602 -795 -707 -848 -553 -130 -31 305 558 588 584 203 212 62 -225 -544 -467 -448 -476 -283 194 181 269 269 186 236 379 451 510 706 152 -337 -354 -599 -854 -132 414 531 414 164 -147 -500 -459 -258 84 329 590 509 508 509 424 -16 -524 -693 -967 -837 -482 -223 -4 296 195 130 29 143 342 392 442 254 130 22 -107 -350 -391 -307 -439 -165 82 115 -136 -240 -567 -725 -566 -277 -333 -206 67 128 46 11 13 62 29 268 713 685 659 629 436 -52 -494 -731 -775 -786 -710 -115 44 60 -27 -408 -599 -566 -200 -85 158 292 448 630 881 840 504 248 23 -272 -324 -88 -43 216 443 344 328 586 187 7 -76 -346 -685 -385 -118 -92 4 151 282 291 367 379 402 436 150 -350 -579 -762 -684