File name: Pandora196s1_Sapporo_20230831_L2Fit_fsus1c1d20220907p1-8.txt File generation date: 20230904T155114.9Z Data description: Level 2 spectral fitting results file Data file version: fsus1c1p1-8 Local principal investigator: Masatomo Fujiwara Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 196 Spectrometer number: 1 Processing software version used: BlickP v1.8.49 Instrument operation file used: Pandora196_OF_v4d20210122.txt Instrument calibration file used: Pandora196s1_CF_v1d20220907.txt Level 1 file used: Pandora196s1_Sapporo_20230831_L1_smca1c1d20220907p1-8.txt Full location name: Hokkaido University, Environmental Earth Science, Building A, Sapporo, Japan Short location name: Sapporo Country of location: Japan Location latitude [deg]: 43.0727 Location longitude [deg]: 141.3459 Location altitude [m]: 46 Local noon date: 20230831 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 214 359 Nominal wavelengths inside fitting window [nm]: 306.0389 306.1802 306.3214 306.4625 306.6037 306.7449 306.8860 307.0272 307.1683 307.3094 307.4506 307.5917 307.7327 307.8738 308.0149 308.1560 308.2970 308.4380 308.5791 308.7201 308.8611 309.0021 309.1431 309.2840 309.4250 309.5659 309.7069 309.8478 309.9887 310.1296 310.2705 310.4114 310.5523 310.6932 310.8340 310.9748 311.1157 311.2565 311.3973 311.5381 311.6789 311.8197 311.9604 312.1012 312.2419 312.3827 312.5234 312.6641 312.8048 312.9455 313.0861 313.2268 313.3675 313.5081 313.6487 313.7894 313.9300 314.0706 314.2112 314.3517 314.4923 314.6329 314.7734 314.9139 315.0545 315.1950 315.3355 315.4760 315.6164 315.7569 315.8974 316.0378 316.1782 316.3187 316.4591 316.5995 316.7399 316.8802 317.0206 317.1610 317.3013 317.4416 317.5820 317.7223 317.8626 318.0029 318.1431 318.2834 318.4237 318.5639 318.7041 318.8444 318.9846 319.1248 319.2649 319.4051 319.5453 319.6854 319.8256 319.9657 320.1058 320.2459 320.3860 320.5261 320.6662 320.8063 320.9463 321.0864 321.2264 321.3664 321.5064 321.6464 321.7864 321.9264 322.0663 322.2063 322.3462 322.4861 322.6261 322.7660 322.9059 323.0457 323.1856 323.3255 323.4653 323.6052 323.7450 323.8848 324.0246 324.1644 324.3042 324.4439 324.5837 324.7234 324.8632 325.0029 325.1426 325.2823 325.4220 325.5617 325.7013 325.8410 325.9806 326.1203 326.2599 326.3995 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------