File name: Pandora164s1_Seosan_20201213_L2Fit_fout2c15d20201112p1-8.txt File generation date: 20241227T124723.8Z Data description: Level 2 spectral fitting results file Data file version: fout2c15p1-8 Local principal investigator: Jinsoo Park Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 164 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora164_OF_v1d20201014.txt Instrument calibration file used: Pandora164s1_CF_v15d20201112.txt Level 1 file used: Pandora164s1_Seosan_20201213_L1_smca1c15d20201112p1-8.txt Full location name: Institute of Atmospheric Environment, Chungcheong Province Short location name: Seosan Country of location: Korea, Republic of Location latitude [deg]: 36.7769 Location longitude [deg]: 126.4938 Location altitude [m]: 25 Local noon date: 20201213 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, radiometric temperature correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 235 377 Nominal wavelengths inside fitting window [nm]: 305.0260 305.1674 305.3087 305.4501 305.5914 305.7327 305.8740 306.0152 306.1565 306.2977 306.4389 306.5801 306.7213 306.8624 307.0036 307.1447 307.2858 307.4269 307.5679 307.7090 307.8500 307.9910 308.1320 308.2730 308.4140 308.5549 308.6958 308.8367 308.9776 309.1185 309.2594 309.4002 309.5410 309.6818 309.8226 309.9634 310.1042 310.2449 310.3856 310.5263 310.6670 310.8077 310.9484 311.0890 311.2296 311.3702 311.5108 311.6514 311.7920 311.9325 312.0730 312.2136 312.3541 312.4945 312.6350 312.7755 312.9159 313.0563 313.1967 313.3371 313.4775 313.6179 313.7582 313.8985 314.0389 314.1792 314.3194 314.4597 314.6000 314.7402 314.8805 315.0207 315.1609 315.3011 315.4412 315.5814 315.7215 315.8616 316.0018 316.1419 316.2819 316.4220 316.5621 316.7021 316.8421 316.9822 317.1221 317.2621 317.4021 317.5421 317.6820 317.8219 317.9619 318.1018 318.2416 318.3815 318.5214 318.6612 318.8011 318.9409 319.0807 319.2205 319.3602 319.5000 319.6398 319.7795 319.9192 320.0589 320.1986 320.3383 320.4780 320.6176 320.7573 320.8969 321.0365 321.1761 321.3157 321.4553 321.5948 321.7344 321.8739 322.0134 322.1529 322.2924 322.4319 322.5714 322.7108 322.8503 322.9897 323.1291 323.2685 323.4079 323.5473 323.6866 323.8260 323.9653 324.1046 324.2439 324.3832 324.5225 324.6618 324.8010 324.9403 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Ozone effective temperature [K] Column 28: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Sulfur dioxide effective temperature [K] Column 39: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 45: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 46: Lower limit used for wavelength scaling [nm] Column 47: Upper limit used for wavelength scaling [nm] Column 48: Order of smoothing polynomial Column 49: Smoothing polynomial coefficient, order 0 Column 50: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 51: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 52: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 53: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 54: Smoothing polynomial coefficient, order 1 Column 55: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 56: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 57: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 58: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 59: Smoothing polynomial coefficient, order 2 Column 60: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 61: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 62: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 63: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 64: Smoothing polynomial coefficient, order 3 Column 65: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 66: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 67: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 68: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 69: Mean value of measured data inside fitting window [same units as measurements] Column 70: Wavelength change polynomial coefficient, order 0 Column 71: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 72: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 76: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 77: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 78: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 80: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 81: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 83: Atmospheric variability [%], 999=no atmospheric variability was determined Column 84: Wavelength effective temperature [°C], 999=no effective temperature given Column 85: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 86: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 87: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 88: Number of bright count cycles Column 89: Number of dark count cycles Column 90: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 91: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 92: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 93: Integration time [ms] Column 94: Temperature at electronics board [°C], 999=no temperature signal Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Humidity in head sensor [%], -9=no humidity signal Column 99: Pressure in head sensor [hPa], -9=no pressure signal Columns 100-242: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 243-385: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20201213T055143.2Z 7652.244251 308 1 50.50 2 68.83 215.27 78.10 234.08 0.00 1 0.00 1 0 25 3.513e-02 6.063e-03 1.539e-02 1.424e-03 3.774362e-01 7.052269e-04 4.376680e-03 -6.000000e+00 1.968031e-02 223.59 -2.00 3.43 -2.00 319.39 0.00e+00 9.267372e-04 1.855436e-04 2.786152e-04 -6.000000e+00 8.739692e-04 280.71 -2.00 20.00 -2.00 318.72 0.00e+00 2.743 0.000 302.00 328.00 3 2.8801e+00 1.9686e-03 3.3135e-02 -6.0000e+00 4.8473e-02 -2.6856e-02 2.3089e-03 1.8988e-02 -6.0000e+00 5.2813e-02 6.8713e-03 1.7771e-03 9.4446e-03 -6.0000e+00 3.1530e-02 -8.9437e-03 9.3971e-04 2.9064e-03 -6.0000e+00 1.3480e-02 1.2397e-03 -4.7101e-04 4.1847e-05 3.1001e-05 -6.0000e+00 9.3484e-04 1.6149e-03 -7.9125e-05 10 0 0 10 0 0 98.72 20.99 0.26 0.00161 -0.00192 117 23 1 5 0 427.890 24.35 20.00 20.99 8.59 8.4 926.51 -17558 -10468 -9261 -5378 1334 -15587 -10661 -11535 -2327 -6724 -12576 -8792 -11917 -3493 -8716 -3293 638 133 -46 -1889 -1922 -245 183 -2471 -284 1304 -129 1791 -1704 -400 -1464 1624 2594 -1261 502 -3728 -2229 -2795 -1515 -2062 -2747 -787 -714 -755 -195 228 186 -155 656 -18 952 474 712 1027 399 1107 396 604 678 843 1300 990 985 1063 787 935 1515 407 1053 701 -198 258 -163 219 183 690 1108 535 1041 -556 -1013 -1412 -2107 -984 -1004 -1040 -726 -154 104 219 568 874 937 1290 922 397 576 546 -429 -456 -393 -472 -96 133 -931 -1175 -529 -813 -191 -26 -35 -194 -156 212 150 940 655 460 172 -661 -620 -448 -112 -46 675 296 744 1906 812 702 130 138 84 357 -55 -341 -110 -53 -433 -329 -122 -182 12 -483 -308 -287 -156 32 -424 -292 -359 -75 -246 -494 -346 -559 -180 -564 -232 47 10 -4 -168 -176 -22 17 -249 -30 143 -15 190 -176 -41 -166 200 353 -190 71 -529 -338 -498 -324 -529 -792 -236 -223 -240 -62 73 59 -49 207 -6 327 179 287 442 181 512 189 288 316 387 611 504 504 594 452 505 843 226 621 431 -135 185 -117 151 117 432 630 295 605 -376 -714 -1120 -1819 -883 -963 -1071 -787 -172 116 235 565 797 792 1066 820 397 649 691 -590 -622 -503 -552 -104 147 -1126 -1510 -708 -1153 -286 -38 -55 -319 -250 320 228 1340 932 684 274 -1033 -984 -696 -184 -73 1009 425 1014 2597 1214 1145 209 232 144 639 -106 -690 -227 -112 -926 -682 -242 -346 23 SS 20201213T055853.2Z 7652.249227 312 1 50.37 2 69.67 216.78 79.24 235.27 0.00 1 0.00 1 0 25 3.691e-02 5.791e-03 1.712e-02 1.393e-03 3.934652e-01 6.916986e-04 4.538306e-03 -6.000000e+00 2.067931e-02 223.59 -2.00 3.43 -2.00 319.53 0.00e+00 1.321542e-03 1.897579e-04 2.760638e-04 -6.000000e+00 9.182256e-04 280.71 -2.00 20.00 -2.00 318.86 0.00e+00 2.849 0.000 302.00 328.00 3 2.7038e+00 1.9424e-03 3.4467e-02 -6.0000e+00 5.0933e-02 -1.8907e-02 2.2911e-03 1.9852e-02 -6.0000e+00 5.5490e-02 2.4579e-03 1.8117e-03 9.8801e-03 -6.0000e+00 3.3129e-02 -7.6904e-03 9.5678e-04 3.2220e-03 -6.0000e+00 1.4167e-02 1.3016e-03 -3.3239e-04 4.0857e-05 3.3533e-05 -6.0000e+00 9.8200e-04 1.1006e-03 -4.3049e-05 10 0 0 10 0 0 94.02 21.00 0.31 0.00110 -0.00140 136 27 1 5 0 367.540 24.35 20.00 21.00 9.21 8.6 933.67 -15794 -2559 -20874 -6013 -12524 -6904 -11098 -9509 -3794 -15487 -3492 -13129 -6250 -8276 -5852 -787 -2433 73 -3904 809 -1500 -638 102 -1963 680 -761 360 -2352 110 325 256 107 -139 -224 -1578 -1219 -3071 -3133 -1872 -2720 -801 -1792 -1171 -878 -46 413 -851 1131 -925 625 622 439 860 569 819 743 878 222 1041 1002 1301 973 966 1582 500 1002 943 1120 1377 214 55 -85 267 514 33 770 617 769 603 -316 -991 -1157 -1884 -1396 -836 -963 -544 -359 -110 246 447 844 881 1238 877 567 601 404 -231 -588 -300 -455 229 370 -1034 -1201 -836 -755 -337 139 -99 -184 -13 53 251 678 514 500 88 -395 -743 -310 -212 155 669 424 864 1654 801 354 316 87 191 355 -50 -301 -217 -29 -418 -374 -146 -194 152 -367 -60 -629 -153 -304 -150 -265 -252 -108 -536 -109 -471 -244 -397 -327 -48 -166 5 -306 63 -124 -52 8 -178 64 -77 37 -236 10 30 26 12 -18 -31 -211 -157 -437 -522 -374 -654 -211 -507 -343 -262 -14 124 -257 334 -280 191 204 158 331 235 353 330 399 102 462 440 585 475 475 846 277 575 511 600 787 129 37 -59 186 342 20 468 342 412 344 -209 -685 -899 -1595 -1237 -787 -974 -578 -394 -121 260 437 757 735 1011 772 562 673 510 -316 -800 -383 -530 246 404 -1243 -1532 -1114 -1061 -503 205 -157 -302 -21 81 384 974 736 747 141 -618 -1183 -481 -349 245 1001 609 1180 2268 1204 583 511 148 332 645 -97 -616 -457 -63 -905 -786 -292 -372 282 SS 20201213T060453.2Z 7652.253393 315 1 50.36 2 70.40 218.02 80.21 236.25 0.00 1 0.00 1 0 25 3.900e-02 5.810e-03 2.656e-02 1.824e-03 4.058684e-01 9.124647e-04 4.733255e-03 -6.000000e+00 2.183942e-02 223.59 -2.00 3.43 -2.00 319.74 0.00e+00 1.328474e-03 2.655788e-04 2.973192e-04 -6.000000e+00 9.699975e-04 280.71 -2.00 20.00 -2.00 319.07 0.00e+00 2.948 0.000 302.00 328.00 3 2.9539e+00 2.6037e-03 3.5739e-02 -6.0000e+00 5.3790e-02 -2.3471e-02 3.0952e-03 2.0678e-02 -6.0000e+00 5.8612e-02 5.7824e-03 2.5016e-03 1.0275e-02 -6.0000e+00 3.4991e-02 -8.5730e-03 1.3104e-03 3.2388e-03 -6.0000e+00 1.4957e-02 9.0840e-04 -7.7052e-04 5.4181e-05 3.7008e-05 -6.0000e+00 1.0377e-03 2.3058e-03 -1.1299e-04 10 0 0 10 0 0 99.94 21.02 0.30 0.00231 -0.00348 116 23 1 5 0 430.300 24.46 20.00 21.02 9.79 8.5 936.71 -5691 -7762 -14504 -19623 -4900 -20019 6203 -8167 -5278 -5946 -8583 -11898 -14312 -8465 -8529 451 485 -8449 -3073 -3560 -1637 -2749 1292 -1981 174 -1406 -181 -1296 3144 2394 -2289 161 581 -997 -1533 67 -894 -3645 -2018 -2267 -2498 -1921 -928 556 -197 -154 -295 621 -242 323 587 485 1008 1031 712 1002 -93 496 862 1133 984 1406 969 995 764 1640 567 737 1373 714 -312 -178 -149 333 315 285 1106 383 552 -255 -841 -1171 -2016 -1104 -1048 -1036 -827 -363 200 159 863 960 1126 1098 1102 782 491 648 -318 -537 -522 -547 -43 271 -883 -1259 -790 -916 -130 89 -92 -30 -129 134 141 1010 590 567 308 -551 -706 -410 -27 56 713 425 622 1480 740 359 168 163 218 203 -73 -431 -229 63 -500 -322 -5 3 20 -100 -162 -346 -482 -93 -420 106 -182 -130 -160 -241 -362 -522 -352 -426 24 28 -571 -210 -257 -119 -202 94 -159 15 -127 -16 -115 252 195 -216 17 68 -126 -186 8 -113 -555 -368 -495 -612 -497 -248 150 -54 -42 -81 170 -67 92 179 162 360 395 287 414 -40 212 358 463 415 639 491 502 397 881 291 375 744 445 -197 -118 -99 211 203 165 579 196 300 -161 -555 -871 -1638 -935 -950 -1006 -845 -381 209 162 806 825 900 865 935 749 533 790 -422 -708 -647 -619 -44 287 -1025 -1554 -1018 -1250 -188 140 -155 -52 -222 217 211 1415 827 829 482 -921 -1198 -680 -44 86 1042 596 832 1988 1091 582 293 296 408 397 -139 -871 -474 132 -1067 -665 -10 6 40 SS 20201213T063830.9Z 7652.276747 331 1 49.88 2 74.85 224.64 85.83 241.49 0.00 1 0.00 1 0 25 2.110e-01 7.104e-03 1.408e-01 3.542e-03 5.118413e-01 1.830140e-03 5.823249e-03 -6.000000e+00 1.181195e-01 223.59 -2.00 3.43 -2.00 320.65 0.00e+00 2.883058e-03 7.238326e-04 9.025335e-04 -6.000000e+00 5.246733e-03 280.70 -2.00 20.00 -2.00 320.05 0.00e+00 3.754 0.001 302.00 328.00 3 2.9237e+00 5.6791e-03 4.5786e-02 -6.0000e+00 2.9093e-01 -3.7754e-03 7.2414e-03 2.7576e-02 -6.0000e+00 3.1702e-01 -1.4930e-02 6.8494e-03 1.3368e-02 -6.0000e+00 1.8926e-01 -1.3041e-03 3.4331e-03 5.1269e-03 -6.0000e+00 8.0886e-02 3.7970e-04 -1.1535e-03 1.0471e-04 5.1234e-05 -6.0000e+00 5.6137e-03 3.1178e-03 -1.2137e-04 11 8 0 10 0 0 99.99 21.08 0.35 0.00312 -0.00555 78 15 1 5 0 639.360 24.46 19.99 21.08 8.95 8.4 927.94 -96289 -88714 -52277 -18792 -63691 101576 -64674 -45092 -73941 -53185 69412 -45482 -8932 -26990 30718 -15805 -9220 1409 -17175 20584 -10877 -1101 -12365 -18441 10390 -8184 2984 -17151 -1594 -2930 -12607 -1713 -4626 4823 -6969 -5469 -2924 -7134 -3354 -6750 -1279 -2220 658 954 -223 3226 -4973 1452 -3780 5123 -849 3677 2054 186 2492 -528 3233 -1281 1178 3381 1332 2137 735 2158 2044 2032 1621 2282 1416 274 710 191 390 -218 67 1152 -181 1975 710 543 -106 -1682 -1747 -2230 -525 -1493 -591 -1045 199 608 474 1632 699 1276 901 280 614 319 -268 -837 70 -242 253 727 -1752 -1308 -1296 -553 -370 81 64 -24 -277 230 467 624 854 452 26 -819 -944 -60 -194 407 619 380 949 1367 553 517 537 -156 161 202 -284 -238 -225 293 -483 -270 7 -206 157 -1299 -1318 -601 -157 -740 351 -769 -507 -1238 -791 326 -698 -116 -527 427 -402 -246 38 -587 520 -382 -35 -454 -778 360 -362 121 -813 -64 -123 -669 -95 -298 307 -480 -367 -208 -611 -338 -847 -172 -322 98 145 -35 497 -842 235 -660 856 -165 757 467 47 644 -146 885 -367 321 889 368 640 251 809 803 768 593 835 566 127 364 103 210 -112 32 485 -72 761 302 265 -60 -1101 -1226 -1662 -411 -1263 -523 -958 180 531 393 1239 505 918 712 254 623 369 -332 -1060 83 -260 253 730 -1911 -1506 -1568 -706 -508 120 103 -41 -466 368 695 897 1222 678 40 -1367 -1586 -97 -305 624 904 535 1274 1871 844 859 966 -298 320 412 -623 -540 -523 692 -1152 -631 15 -434 325 SS 20201213T070354.4Z 7652.294379 343 1 50.70 2 78.57 229.26 90.25 245.20 0.00 1 0.00 1 0 25 7.326e-01 8.088e-02 4.828e-01 7.083e-02 5.747778e-01 4.018895e-02 6.964357e-03 -6.000000e+00 4.268016e-01 223.59 -2.00 3.43 -2.00 321.13 0.00e+00 2.970383e-02 1.696427e-02 2.543337e-03 -6.000000e+00 3.012046e-02 280.70 -2.00 20.00 -2.00 320.61 0.00e+00 4.877 0.002 302.00 328.00 3 4.9998e+00 1.2829e-01 6.7822e-02 -6.0000e+00 1.0642e+00 4.8615e-01 1.5035e-01 6.9029e-02 -6.0000e+00 1.1707e+00 -7.5552e-01 1.1043e-01 1.7651e-02 -6.0000e+00 6.8139e-01 3.7301e-01 5.7530e-02 2.9802e-02 -6.0000e+00 3.0587e-01 1.2783e-05 -1.1884e-03 2.1715e-03 3.0212e-04 -6.0000e+00 2.2009e-02 1.2286e-03 3.0586e-04 12 8 8 10 0 0 99.98 21.05 3.25 0.00123 -0.00770 33 6 1 5 0 1535.930 24.46 19.99 21.05 8.93 8.4 928.37 900000 900000 -84876 900000 900000 -1476 900000 -184187 900000 900000 900000 900000 900000 900000 900000 900000 15337 115763 59250 -47466 -4449 162146 314045 900000 900000 -12548 900000 900000 288263 -123012 62810 11592 900000 900000 -82077 -24511 417658 121316 900000 72113 125984 -34934 26136 149586 17320 186301 -33310 900000 94537 -723 50547 900000 25229 -13226 81311 39326 79894 -12958 -5606 16902 8562 54029 66000 67485 24865 -15911 -2016 -20834 13155 10154 1522 26522 4278 12812 4907 25228 7849 -4300 12889 3221 10335 -13715 21922 -21671 5171 -6361 8097 1559 3579 16416 -10933 -5334 -2516 3567 -11824 -1605 3059 -8270 11159 -5471 7090 538 -855 -8315 -4277 8501 -11118 -3877 -7042 -187 -4179 -4659 10610 -2606 2172 -2061 10901 5737 -2633 681 -954 -1876 297 637 6036 2073 8506 5028 -201 3832 6442 7703 -3433 -1529 889 -4328 -3115 5375 -1783 -3297 557 -5707 7284 900000 900000 -6104 900000 900000 -101 900000 -20065 900000 900000 900000 900000 900000 900000 900000 900000 1054 7959 4073 -4610 -306 11147 21590 900000 900000 -863 900000 900000 19818 -18256 4318 797 900000 900000 -14241 -2265 28713 8340 900000 4958 8661 -5462 2426 10284 1945 12808 -6575 900000 6499 -116 5270 900000 3867 -3130 7864 5587 7541 -2906 -1131 2769 1609 7303 9075 10207 6053 -5593 -602 -7467 3543 3193 575 8100 1610 4173 1582 6042 2059 -1271 3559 1151 4042 -7760 9487 -14970 2937 -4253 5019 1070 2432 9565 -7824 -3337 -1440 1926 -8222 -1174 2499 -8629 10616 -6236 6848 502 -729 -7534 -3991 7425 -12468 -4339 -8865 -245 -6209 -7377 14672 -3956 2957 -2787 12973 7540 -4009 1057 -1508 -2898 434 893 7666 2637 9921 6216 -287 5907 10586 13273 -6878 -3151 1899 -10228 -7419 11921 -4251 -7689 1176 -12040 13120