File name: Pandora235s1_Seoul-KU_20241014_L2Fit_fout2c1d20230717p1-8.txt File generation date: 20241014T152640.1Z Data description: Level 2 spectral fitting results file Data file version: fout2c1p1-8 Local principal investigator: ---- Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 235 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora235_OF_v4d20230606.txt Instrument calibration file used: Pandora235s1_CF_v1d20230717.txt Level 1 file used: Pandora235s1_Seoul-KU_20241014_L1_smca1c1d20230717p1-8.txt Full location name: Korea University, Seoul Campus Short location name: Seoul-KU Country of location: Korea, Republic of Location latitude [deg]: 37.5855 Location longitude [deg]: 127.0257 Location altitude [m]: 90 Local noon date: 20241014 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: Full initial lab calibration analysis and OoB session First and last pixel inside fitting window: 199 341 Nominal wavelengths inside fitting window [nm]: 305.0718 305.2128 305.3538 305.4948 305.6357 305.7767 305.9176 306.0585 306.1995 306.3404 306.4813 306.6221 306.7630 306.9039 307.0447 307.1855 307.3263 307.4672 307.6080 307.7487 307.8895 308.0303 308.1710 308.3118 308.4525 308.5932 308.7339 308.8746 309.0153 309.1560 309.2966 309.4373 309.5779 309.7185 309.8591 309.9997 310.1403 310.2809 310.4215 310.5620 310.7026 310.8431 310.9836 311.1241 311.2646 311.4051 311.5456 311.6860 311.8265 311.9669 312.1073 312.2477 312.3881 312.5285 312.6689 312.8093 312.9496 313.0900 313.2303 313.3706 313.5109 313.6512 313.7915 313.9318 314.0720 314.2123 314.3525 314.4927 314.6329 314.7731 314.9133 315.0535 315.1937 315.3338 315.4740 315.6141 315.7542 315.8943 316.0344 316.1745 316.3146 316.4546 316.5947 316.7347 316.8747 317.0147 317.1547 317.2947 317.4347 317.5747 317.7146 317.8546 317.9945 318.1344 318.2743 318.4142 318.5541 318.6940 318.8338 318.9737 319.1135 319.2533 319.3931 319.5329 319.6727 319.8125 319.9522 320.0920 320.2317 320.3715 320.5112 320.6509 320.7906 320.9302 321.0699 321.2096 321.3492 321.4888 321.6284 321.7681 321.9076 322.0472 322.1868 322.3264 322.4659 322.6054 322.7450 322.8845 323.0240 323.1635 323.3029 323.4424 323.5818 323.7213 323.8607 324.0001 324.1395 324.2789 324.4183 324.5577 324.6970 324.8364 324.9757 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Ozone effective temperature [K] Column 28: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Sulfur dioxide effective temperature [K] Column 39: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 45: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 46: Lower limit used for wavelength scaling [nm] Column 47: Upper limit used for wavelength scaling [nm] Column 48: Order of smoothing polynomial Column 49: Smoothing polynomial coefficient, order 0 Column 50: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 51: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 52: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 53: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 54: Smoothing polynomial coefficient, order 1 Column 55: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 56: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 57: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 58: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 59: Smoothing polynomial coefficient, order 2 Column 60: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 61: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 62: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 63: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 64: Smoothing polynomial coefficient, order 3 Column 65: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 66: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 67: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 68: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 69: Mean value of measured data inside fitting window [same units as measurements] Column 70: Wavelength change polynomial coefficient, order 0 Column 71: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 72: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 76: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 77: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 78: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 80: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 81: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 83: Atmospheric variability [%], 999=no atmospheric variability was determined Column 84: Wavelength effective temperature [°C], 999=no effective temperature given Column 85: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 86: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 87: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 88: Number of bright count cycles Column 89: Number of dark count cycles Column 90: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 91: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 92: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 93: Integration time [ms] Column 94: Spectrometer control temperature [°C], 999=no temperature signal Column 95: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 96: Temperature in head sensor [°C], 999=no temperature signal Column 97: Temperature at electronics board 1 [°C], 999=no temperature signal Column 98: Temperature at electronics board 2 [°C], 999=no temperature signal Column 99: Humidity in head sensor [%], -9=no humidity signal Column 100: Pressure in head sensor [hPa], -9=no pressure signal Columns 101-243: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 244-386: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20241014T001408.7Z 9053.009823 175 1 48.43 2 62.76 126.87 156.03 355.15 0.00 1 0.00 1 0 17 2.751e-02 9.932e-03 4.874e-03 1.888e-03 2.655323e-01 9.854315e-04 3.167565e-03 -6.000000e+00 1.630839e-02 226.47 -2.00 3.44 -2.00 316.81 0.00e+00 3.364151e-04 1.289429e-04 1.712377e-04 -6.000000e+00 7.345656e-04 286.28 -2.00 20.00 -2.00 316.06 0.00e+00 2.173 0.000 302.00 328.00 3 4.9313e+00 2.5713e-03 2.5277e-02 -6.0000e+00 4.0314e-02 -1.8399e-03 2.8793e-03 1.3385e-02 -6.0000e+00 4.3639e-02 6.9023e-03 1.6951e-03 6.5693e-03 -6.0000e+00 2.6083e-02 -9.9335e-03 8.1976e-04 1.8464e-03 -6.0000e+00 1.1183e-02 3.2865e-04 -5.9103e-04 5.7988e-05 2.3738e-05 -6.0000e+00 8.2407e-04 -8.5038e-02 0.0000e+00 12 9 9 12 9 1 99.83 24.55 0.58 -0.08504 -0.08948 15 2 1 8 0 3026.460 20.00 24.55 26.97 32.50 32.75 1.2 967.51 900000 10086 -6528 -14720 296 -4311 -8263 2440 2604 -494 -3932 -1568 -13051 1533 7825 -625 585 5666 -1864 4510 -3217 -188 -2392 1021 5178 1974 -1339 2410 -1661 -2802 1865 3842 2013 1766 -1320 -4901 5251 -2102 -1159 -364 -1680 -559 103 -607 -489 1209 2895 -2285 -1602 -570 -660 -1067 555 901 1684 1384 -136 -485 -175 751 -88 817 3470 1209 1885 -310 539 201 317 1428 -313 531 31 112 -428 -829 163 618 -1288 -1964 -950 -2879 -2662 -2785 -377 546 -292 585 -129 -197 192 658 -177 -172 387 145 246 2053 369 -286 -739 -559 -563 1083 -402 -1711 -578 -272 91 991 445 342 583 -343 244 -2 787 678 -443 96 -117 262 37 -130 -44 234 846 709 -92 -313 201 -853 -602 329 -76 -417 294 361 471 -9 468 -936 -577 900000 1298 -956 -2311 41 -572 -1144 330 393 -83 -642 -253 -2540 293 1608 -157 156 1505 -557 1312 -954 -59 -716 307 1578 650 -464 783 -529 -868 613 1218 702 652 -497 -1841 1842 -895 -534 -197 -964 -340 65 -393 -317 770 1799 -1465 -1001 -350 -419 -724 369 630 1220 1033 -106 -379 -135 567 -68 658 2760 1056 1686 -273 438 166 251 1228 -286 514 31 109 -398 -753 133 495 -1050 -1643 -885 -2864 -2712 -3010 -421 614 -353 730 -156 -248 227 751 -187 -181 412 158 281 2558 480 -383 -955 -706 -665 1246 -496 -2178 -766 -358 126 1438 657 522 876 -493 338 -2 1026 906 -603 139 -169 379 55 -188 -60 321 1098 903 -123 -426 290 -1233 -889 497 -122 -673 490 590 779 -15 776 -1519 -907 SS 20241014T001957.1Z 9053.013855 178 1 55.15 2 61.85 128.13 156.07 358.46 0.00 1 0.00 1 0 17 2.545e-02 1.011e-02 3.809e-03 1.601e-03 2.628286e-01 8.365761e-04 3.152001e-03 -6.000000e+00 1.508339e-02 226.47 -2.00 3.44 -2.00 316.65 0.00e+00 2.435706e-04 1.047932e-04 1.810783e-04 -6.000000e+00 6.794745e-04 286.28 -2.00 20.00 -2.00 315.90 0.00e+00 2.109 0.000 302.00 328.00 3 4.8738e+00 2.1765e-03 2.4684e-02 -6.0000e+00 3.7286e-02 9.2140e-03 2.4337e-03 1.3262e-02 -6.0000e+00 4.0363e-02 -4.0635e-03 1.4246e-03 6.5105e-03 -6.0000e+00 2.4125e-02 -1.7914e-03 6.8062e-04 1.8281e-03 -6.0000e+00 1.0341e-02 3.7040e-04 -5.6165e-04 4.9147e-05 2.4411e-05 -6.0000e+00 7.6232e-04 -8.3665e-02 0.0000e+00 12 8 8 10 0 0 99.54 24.55 0.63 -0.08366 -0.08789 19 2 1 8 0 2902.420 20.00 24.55 27.12 32.50 33.00 1.1 968.68 900000 10279 -4369 -13923 745 -3266 -11309 3192 2132 -574 -4722 -1125 -9748 1079 5332 -635 785 5175 -3218 3554 -2897 43 -1419 2992 5027 1079 -1946 2135 -775 -1626 867 2914 3573 1639 -1512 -3335 3517 -1116 -983 90 -1582 -431 407 -568 -572 1695 2123 -1617 -1558 -592 -169 -1276 570 466 1482 918 277 -547 -379 367 -617 1056 2800 1077 1187 -622 244 105 334 1591 -372 404 254 0 -316 -392 -24 489 -1050 -1494 -1129 -2687 -2902 -2482 -562 154 -425 449 -167 -214 -116 560 -133 -395 274 378 780 2551 526 -268 -771 -84 -742 1155 -451 -1607 -591 -99 88 1105 558 884 513 29 406 -112 860 786 115 -226 -199 126 -112 -215 -137 43 267 380 18 -289 110 -1055 -658 94 57 -669 -186 96 -15 -307 -132 2275 -1118 900000 1492 -705 -2436 114 -480 -1806 479 361 -98 -864 -201 -2035 229 1239 -176 230 1513 -976 1044 -933 14 -457 958 1665 389 -735 752 -264 -536 284 1002 1317 649 -609 -1317 1341 -502 -483 48 -966 -279 253 -363 -367 1138 1406 -1088 -1026 -384 -113 -853 398 344 1130 678 210 -421 -288 273 -471 834 2347 926 1050 -539 207 85 276 1422 -354 384 248 0 -305 -346 -20 381 -831 -1291 -1028 -2611 -3067 -2621 -617 181 -504 551 -209 -264 -135 625 -144 -407 285 423 915 3095 670 -350 -975 -102 -902 1365 -545 -2102 -766 -134 120 1570 806 1314 756 42 574 -149 1147 1022 159 -320 -294 187 -162 -303 -192 57 356 495 24 -402 154 -1553 -987 137 88 -1054 -303 160 -26 -514 -214 3620 -1789 SS 20241014T015657.6Z 9053.081222 232 1 40.78 2 49.61 153.30 148.51 45.36 0.00 1 0.00 1 0 17 9.922e-03 7.292e-03 1.560e-03 1.050e-03 1.928110e-01 5.563926e-04 2.341658e-03 -6.000000e+00 5.881202e-03 226.46 -2.00 3.44 -2.00 315.06 0.00e+00 2.780428e-04 4.932826e-05 7.293827e-05 -6.000000e+00 2.649305e-04 286.27 -2.00 20.00 -2.00 314.41 0.00e+00 1.540 0.000 302.00 328.00 3 4.4650e+00 1.4187e-03 1.8045e-02 -6.0000e+00 1.4538e-02 9.5683e-03 1.5730e-03 9.6985e-03 -6.0000e+00 1.5738e-02 -2.6033e-03 9.0392e-04 4.7743e-03 -6.0000e+00 9.4065e-03 -4.2506e-03 4.0338e-04 1.3437e-03 -6.0000e+00 4.0322e-03 1.0930e-03 -5.0052e-04 3.2071e-05 2.0210e-05 -6.0000e+00 2.9724e-04 -8.3770e-02 0.0000e+00 12 9 1 12 33 1 99.24 24.57 0.50 -0.08377 -0.08753 27 4 2 8 0 1456.100 20.00 24.57 27.94 32.75 33.00 1.1 972.96 900000 1731 -1056 -3604 -1870 -784 -1907 11 202 -536 -2686 -1292 -2635 187 1599 62 127 -654 296 2031 -48 770 607 1701 1999 1007 119 440 70 556 1312 1730 1662 137 -1966 -2551 118 -2032 -1217 -813 -1267 -593 -216 -396 -292 724 107 -916 -639 -196 362 197 774 857 1031 794 571 -109 109 527 431 1115 2172 1249 709 -290 145 -173 571 1294 271 233 442 273 -86 -439 -331 -932 -925 -1093 -1241 -2165 -2192 -2392 -908 -376 -160 304 56 201 226 199 -327 302 467 121 419 762 315 -503 -585 -415 -743 450 -362 -1431 -623 -390 30 870 864 703 498 87 205 -8 728 428 221 300 -28 84 80 103 101 450 184 605 536 87 36 -670 -363 80 35 -180 -46 342 218 -218 -12 -402 -809 900000 567 -344 -1175 -588 -223 -546 3 68 -194 -936 -442 -960 73 648 28 61 -304 140 973 -24 383 303 866 1061 561 64 241 36 268 669 866 884 77 -1103 -1378 64 -1187 -784 -579 -964 -454 -171 -318 -234 572 83 -736 -496 -149 278 159 627 727 863 680 498 -96 95 452 376 1013 2004 1184 689 -283 135 -153 505 1187 266 244 453 286 -86 -423 -300 -818 -802 -974 -1180 -2199 -2308 -2664 -1015 -431 -195 370 70 245 270 226 -353 315 488 131 477 916 394 -645 -721 -494 -865 516 -428 -1765 -800 -505 40 1179 1190 992 689 117 264 -9 896 539 285 400 -38 115 108 139 134 566 228 729 666 111 47 -904 -496 108 49 -261 -67 509 330 -328 -17 -591 -1165 SS 20241014T054542.4Z 9053.240074 362 1 55.57 2 57.45 224.89 107.61 92.26 0.00 1 0.00 1 0 17 1.837e-02 9.508e-03 3.061e-03 1.543e-03 2.305691e-01 8.093229e-04 2.786882e-03 -6.000000e+00 1.088968e-02 226.45 -2.00 3.44 -2.00 316.11 0.00e+00 2.492238e-04 8.933770e-05 1.325424e-04 -6.000000e+00 4.905272e-04 286.25 -2.00 20.00 -2.00 315.38 0.00e+00 1.852 0.000 302.00 328.00 3 5.1093e+00 2.0888e-03 2.1674e-02 -6.0000e+00 2.6918e-02 8.9078e-03 2.3280e-03 1.1628e-02 -6.0000e+00 2.9140e-02 -2.8269e-03 1.3472e-03 5.7225e-03 -6.0000e+00 1.7417e-02 -2.2843e-03 6.2860e-04 1.6122e-03 -6.0000e+00 7.4663e-03 3.9587e-04 -6.0391e-04 4.7323e-05 2.2220e-05 -6.0000e+00 5.5038e-04 -8.4001e-02 0.0000e+00 12 9 8 11 8 0 99.09 24.62 0.61 -0.08400 -0.08854 22 2 1 8 0 2525.430 20.00 24.62 29.82 32.50 32.75 1.1 983.81 900000 6130 -2958 -9073 -251 -1524 -6238 749 1105 -775 -3247 -1631 -7867 2300 4698 -354 -26 3140 -1542 3025 -1488 336 -158 1866 4315 1697 -768 1255 -538 -939 1150 3788 1983 955 -1749 -3283 2261 -2245 -1437 -1578 -1159 38 72 -528 -750 784 1566 -1777 -1706 -263 -31 -545 822 482 1340 1176 242 -458 -273 477 -401 769 2541 1171 1127 -601 502 126 277 1651 -252 380 261 260 -704 -261 -540 135 -607 -1288 -942 -2520 -2558 -2787 -502 270 -198 590 -121 -8 238 465 -334 -240 362 381 584 2360 334 -405 -923 -382 -382 1137 -524 -1741 -570 -128 -41 1023 787 771 711 236 197 69 693 726 -115 -120 -261 -30 108 -175 -120 -53 12 513 209 -197 -44 -956 -485 -123 68 -552 -150 134 70 -355 -211 2092 -1021 900000 1156 -642 -2052 -48 -269 -1153 140 229 -176 -772 -383 -2089 619 1398 -113 -9 1069 -570 1102 -582 130 -62 738 1750 737 -320 537 -220 -367 445 1514 864 407 -752 -1491 1002 -1081 -752 -972 -747 26 51 -381 -543 557 1091 -1248 -1166 -175 -21 -395 623 361 1037 933 198 -379 -222 382 -328 654 2152 1074 1059 -551 447 107 238 1442 -248 375 263 258 -669 -240 -476 109 -492 -1136 -872 -2482 -2731 -2987 -557 319 -238 731 -153 -10 279 526 -366 -247 375 424 679 2830 419 -522 -1205 -462 -455 1327 -626 -2255 -731 -171 -57 1426 1159 1118 1059 333 269 87 890 953 -154 -164 -373 -43 151 -250 -164 -69 16 643 272 -261 -61 -1336 -688 -179 103 -856 -240 211 111 -562 -338 3168 -1552 SS 20241014T060219.9Z 9053.251619 372 1 4.24 2 59.86 228.80 104.40 94.59 0.00 1 0.00 1 0 17 1.020e-02 7.049e-03 3.668e-03 2.108e-03 2.423046e-01 1.108968e-03 2.908065e-03 -6.000000e+00 6.043947e-03 226.44 -2.00 3.44 -2.00 315.76 0.00e+00 4.672005e-04 1.135014e-04 7.589671e-05 -6.000000e+00 2.722456e-04 286.25 -2.00 20.00 -2.00 315.05 0.00e+00 1.983 0.000 302.00 328.00 3 3.0410e+00 2.8467e-03 2.3046e-02 -6.0000e+00 1.4940e-02 1.7850e-03 3.1676e-03 1.2165e-02 -6.0000e+00 1.6173e-02 -1.2678e-03 1.8239e-03 5.9773e-03 -6.0000e+00 9.6665e-03 -4.3564e-03 8.3450e-04 1.6936e-03 -6.0000e+00 4.1440e-03 2.7148e-03 -5.1579e-04 6.4174e-05 2.3144e-05 -6.0000e+00 3.0546e-04 -8.4199e-02 0.0000e+00 12 9 1 12 1 1 86.57 24.63 0.38 -0.08420 -0.08808 8 11 1 8 0 470.500 20.00 24.63 30.05 32.50 33.00 1.0 983.60 900000 392 -1208 -3134 -2641 -2243 -2624 -380 -1000 -2030 -2167 -1381 -2328 -778 198 679 477 1505 949 765 2048 1320 1231 1686 1275 1881 48 -327 946 360 1507 311 322 -279 -2444 -1921 -1633 -2057 -840 -1027 -860 -681 -449 -614 55 441 14 -321 -517 -21 274 174 1067 1112 921 795 866 27 243 740 494 1163 1637 1513 776 -513 -56 211 366 1277 112 41 152 -36 180 -110 -312 -308 -588 -1476 -1611 -1888 -2534 -1990 -733 -713 -284 50 350 470 384 146 -326 292 578 369 636 578 583 -557 -322 -893 -969 90 -254 -1308 -839 -378 -39 1079 846 398 345 332 -101 -303 604 739 377 225 -166 132 196 278 140 392 -14 516 503 -215 95 -345 -345 88 227 -72 -11 414 78 -168 -99 -421 -837 900000 98 -300 -779 -645 -503 -591 -91 -267 -549 -600 -382 -694 -240 69 246 185 602 396 312 846 552 519 733 586 846 22 -148 421 154 646 144 151 -138 -1220 -916 -803 -1082 -490 -643 -578 -489 -320 -446 40 317 10 -235 -370 -15 198 128 827 871 753 641 711 23 200 599 407 1000 1456 1390 738 -474 -49 184 324 1138 108 41 155 -36 176 -102 -272 -259 -493 -1304 -1542 -1877 -2660 -2129 -822 -830 -340 60 428 564 449 167 -354 306 611 408 729 712 732 -720 -410 -1098 -1151 105 -306 -1656 -1080 -495 -53 1501 1214 575 492 458 -137 -392 771 938 494 308 -232 184 276 379 187 511 -18 644 651 -283 132 -487 -485 127 334 -110 -17 652 122 -267 -153 -645 -1252