File name: Pandora54s1_Seoul_20220422_L2Fit_fnvs4c26d20211117p1-8.txt File generation date: 20250129T201053.8Z Data description: Level 2 spectral fitting results file Data file version: fnvs4c26p1-8 Local principal investigator: Jaemin Hong Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 54 Spectrometer number: 1 Processing software version used: BlickP v1.8.70 Instrument operation file used: Pandora54_OF_v4d20200817.txt Instrument calibration file used: Pandora54s1_CF_v26d20211117.txt Level 1 file used: Pandora54s1_Seoul_20220422_L1_smca1c26d20211117p1-8.txt Full location name: Yonsei University/Seoul Short location name: Seoul Country of location: South Korea Location latitude [deg]: 37.5644 Location longitude [deg]: 126.9340 Location altitude [m]: 86 Local noon date: 20220422 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, radiometric temperature correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 961 1508 Nominal wavelengths inside fitting window [nm]: 400.0218 400.1536 400.2854 400.4173 400.5491 400.6809 400.8126 400.9444 401.0762 401.2079 401.3396 401.4713 401.6030 401.7347 401.8664 401.9980 402.1297 402.2613 402.3929 402.5245 402.6561 402.7876 402.9192 403.0507 403.1822 403.3137 403.4452 403.5767 403.7082 403.8396 403.9711 404.1025 404.2339 404.3653 404.4967 404.6280 404.7594 404.8907 405.0221 405.1534 405.2847 405.4159 405.5472 405.6784 405.8097 405.9409 406.0721 406.2033 406.3345 406.4656 406.5968 406.7279 406.8590 406.9902 407.1212 407.2523 407.3834 407.5144 407.6455 407.7765 407.9075 408.0385 408.1695 408.3004 408.4314 408.5623 408.6932 408.8241 408.9550 409.0859 409.2167 409.3476 409.4784 409.6092 409.7400 409.8708 410.0016 410.1324 410.2631 410.3938 410.5246 410.6553 410.7859 410.9166 411.0473 411.1779 411.3086 411.4392 411.5698 411.7004 411.8309 411.9615 412.0920 412.2225 412.3531 412.4836 412.6140 412.7445 412.8750 413.0054 413.1358 413.2662 413.3966 413.5270 413.6574 413.7877 413.9181 414.0484 414.1787 414.3090 414.4393 414.5696 414.6998 414.8300 414.9603 415.0905 415.2207 415.3508 415.4810 415.6112 415.7413 415.8714 416.0015 416.1316 416.2617 416.3917 416.5218 416.6518 416.7818 416.9118 417.0418 417.1718 417.3018 417.4317 417.5616 417.6916 417.8215 417.9513 418.0812 418.2111 418.3409 418.4707 418.6006 418.7304 418.8601 418.9899 419.1197 419.2494 419.3791 419.5088 419.6385 419.7682 419.8979 420.0275 420.1572 420.2868 420.4164 420.5460 420.6756 420.8051 420.9347 421.0642 421.1937 421.3232 421.4527 421.5822 421.7117 421.8411 421.9705 422.0999 422.2294 422.3587 422.4881 422.6175 422.7468 422.8761 423.0055 423.1347 423.2640 423.3933 423.5226 423.6518 423.7810 423.9102 424.0394 424.1686 424.2978 424.4269 424.5561 424.6852 424.8143 424.9434 425.0725 425.2015 425.3306 425.4596 425.5886 425.7176 425.8466 425.9756 426.1045 426.2335 426.3624 426.4913 426.6202 426.7491 426.8780 427.0068 427.1357 427.2645 427.3933 427.5221 427.6509 427.7796 427.9084 428.0371 428.1659 428.2946 428.4233 428.5519 428.6806 428.8092 428.9379 429.0665 429.1951 429.3237 429.4523 429.5808 429.7094 429.8379 429.9664 430.0949 430.2234 430.3518 430.4803 430.6087 430.7372 430.8656 430.9940 431.1223 431.2507 431.3791 431.5074 431.6357 431.7640 431.8923 432.0206 432.1488 432.2771 432.4053 432.5335 432.6617 432.7899 432.9181 433.0462 433.1744 433.3025 433.4306 433.5587 433.6868 433.8148 433.9429 434.0709 434.1990 434.3270 434.4549 434.5829 434.7109 434.8388 434.9668 435.0947 435.2226 435.3505 435.4783 435.6062 435.7340 435.8618 435.9897 436.1174 436.2452 436.3730 436.5007 436.6285 436.7562 436.8839 437.0116 437.1393 437.2669 437.3946 437.5222 437.6498 437.7774 437.9050 438.0326 438.1601 438.2877 438.4152 438.5427 438.6702 438.7977 438.9251 439.0526 439.1800 439.3074 439.4348 439.5622 439.6896 439.8169 439.9443 440.0716 440.1989 440.3262 440.4535 440.5808 440.7080 440.8353 440.9625 441.0897 441.2169 441.3440 441.4712 441.5983 441.7255 441.8526 441.9797 442.1068 442.2338 442.3609 442.4879 442.6150 442.7420 442.8690 442.9959 443.1229 443.2498 443.3768 443.5037 443.6306 443.7575 443.8844 444.0112 444.1380 444.2649 444.3917 444.5185 444.6453 444.7720 444.8988 445.0255 445.1522 445.2789 445.4056 445.5323 445.6589 445.7856 445.9122 446.0388 446.1654 446.2920 446.4186 446.5451 446.6716 446.7982 446.9247 447.0511 447.1776 447.3041 447.4305 447.5569 447.6834 447.8098 447.9361 448.0625 448.1888 448.3152 448.4415 448.5678 448.6941 448.8204 448.9466 449.0729 449.1991 449.3253 449.4515 449.5777 449.7038 449.8300 449.9561 450.0822 450.2083 450.3344 450.4605 450.5866 450.7126 450.8386 450.9646 451.0906 451.2166 451.3426 451.4685 451.5945 451.7204 451.8463 451.9722 452.0980 452.2239 452.3497 452.4755 452.6014 452.7271 452.8529 452.9787 453.1044 453.2302 453.3559 453.4816 453.6073 453.7329 453.8586 453.9842 454.1098 454.2354 454.3610 454.4866 454.6122 454.7377 454.8632 454.9888 455.1142 455.2397 455.3652 455.4906 455.6161 455.7415 455.8669 455.9923 456.1177 456.2430 456.3684 456.4937 456.6190 456.7443 456.8696 456.9948 457.1201 457.2453 457.3705 457.4957 457.6209 457.7461 457.8712 457.9963 458.1215 458.2466 458.3717 458.4967 458.6218 458.7468 458.8719 458.9969 459.1219 459.2468 459.3718 459.4968 459.6217 459.7466 459.8715 459.9964 460.1213 460.2461 460.3709 460.4958 460.6206 460.7454 460.8701 460.9949 461.1196 461.2444 461.3691 461.4938 461.6184 461.7431 461.8677 461.9924 462.1170 462.2416 462.3662 462.4907 462.6153 462.7398 462.8643 462.9889 463.1133 463.2378 463.3623 463.4867 463.6111 463.7355 463.8599 463.9843 464.1087 464.2330 464.3573 464.4817 464.6060 464.7302 464.8545 464.9787 465.1030 465.2272 465.3514 465.4756 465.5998 465.7239 465.8480 465.9722 466.0963 466.2204 466.3444 466.4685 466.5925 466.7166 466.8406 466.9646 467.0885 467.2125 467.3364 467.4604 467.5843 467.7082 467.8321 467.9559 468.0798 468.2036 468.3274 468.4512 468.5750 468.6988 468.8225 468.9463 469.0700 469.1937 469.3174 469.4410 469.5647 469.6883 469.8120 469.9356 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Temperature at electronics board [°C], 999=no temperature signal Column 159: Spectrometer control temperature [°C], 999=no temperature signal Column 160: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 161: Temperature in head sensor [°C], 999=no temperature signal Column 162: Humidity in head sensor [%], -9=no humidity signal Column 163: Pressure in head sensor [hPa], -9=no pressure signal Columns 164-711: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 712-1259: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20220422T001732.3Z 8147.012180 310 1 50.62 2 49.97 107.46 85.06 229.26 0.00 1 0.00 1 0 33 2.873e-03 2.771e-03 2.293e-03 2.209e-03 2.295658e+03 4.408633e+02 1.919555e+02 6.273283e+02 5.860310e+02 282.84 -2.00 20.00 -2.00 446.12 0.00e+00 4.244059e-04 2.453282e-04 2.314245e-05 2.659446e-05 3.134896e-04 282.84 -2.00 20.00 -2.00 455.35 0.00e+00 5.169439e-04 2.387365e-05 4.053858e-05 4.286971e-05 3.138665e-05 282.84 -2.00 20.00 -2.00 436.77 0.00e+00 -4.430124e+04 3.046870e+05 5.632401e+04 3.813880e+05 4.151295e+05 264.32 -2.00 11.04 -2.00 457.92 0.00e+00 2.083561e-01 6.156364e-02 1.168541e-02 1.683608e-02 9.008672e-02 229.42 -2.00 3.44 -2.00 454.62 0.00e+00 -1.166019e-06 7.683979e-06 1.127240e-06 1.910316e-06 1.095193e-05 282.84 -2.00 20.00 -2.00 455.84 0.00e+00 1.552 0.000 397.00 473.00 4 7.5306e+00 2.4443e-03 4.3046e-03 6.7000e-04 2.9994e-03 1.1384e-02 2.8354e-03 8.2372e-04 4.0752e-04 3.6294e-03 -1.0298e-02 1.6423e-03 1.1649e-04 1.9569e-04 2.0849e-03 -1.7883e-03 5.4152e-04 3.9797e-05 4.8280e-05 6.9474e-04 8.7443e-04 2.8166e-04 2.8496e-05 2.5228e-05 3.4877e-04 7.8629e-04 3.5191e-03 1.6466e-03 1.7828e-04 1.1219e-04 1.7757e-03 3.0439e-05 2.3722e-05 4.2731e-07 7.3884e-07 3.0052e-05 4.0463e-05 3.2466e-05 7.0137e-07 8.7208e-07 4.0656e-05 -3.8324e-03 1.8414e-05 2.9868e-01 2.3282e-01 1.2195e-02 8.3963e-03 2.7350e-01 12 8 8 10 0 0 99.92 21.66 1.20 -0.00383 -0.00660 13 3 2 4 0 3892.906 26.00 20.00 21.66 23.19 25.8 1046.43 698 -113 186 -1130 -2 -310 -276 -562 -59 -61 -293 -352 -286 -44 -190 18 2 206 193 404 -430 490 8 698 427 -92 -204 68 62 -52 468 -516 -106 -806 454 31 89 -100 110 -51 726 -16 117 -272 26 44 -133 -7 -497 435 -273 -10 14 -36 -113 133 297 -103 658 -129 117 -220 562 -211 346 -108 258 32 236 359 129 466 -604 105 155 261 -3 205 -27 -626 342 -256 -190 38 870 -226 426 -47 -28 -145 349 261 -1 -242 90 232 -161 70 -139 -304 -219 374 -421 49 68 411 578 141 75 -458 129 -120 324 -117 -156 -468 104 -168 122 -484 112 -41 -8 -83 -317 84 -291 -25 -327 -29 -433 319 -334 -79 256 12 -373 -118 -172 -169 39 -4 306 -315 269 121 -122 -306 -437 -111 273 36 141 -19 145 -30 -171 443 -201 626 43 -21 -154 193 9 107 213 -131 403 -239 511 -255 251 -225 484 -82 -44 -95 -171 -230 -382 -214 -390 -367 -200 207 -444 -228 -99 582 -579 -182 -464 -514 -123 474 62 157 -46 -41 206 -454 -128 -444 95 -429 205 217 242 -140 -576 255 -179 577 -424 -110 -84 215 -58 -22 -107 -422 -23 -98 548 -293 114 362 -246 249 494 -356 -145 -566 24 -17 360 3 -422 223 178 435 152 504 42 647 10 250 215 342 204 202 530 423 326 112 445 -24 -354 -431 268 -139 -293 285 -239 48 -141 -50 -405 457 216 99 -247 -344 -277 209 -253 -108 257 -214 57 -633 394 -210 297 -174 92 -34 113 9 363 -70 -104 -84 -291 202 -564 675 -654 -149 152 4 -42 201 242 251 -281 -3 124 -498 110 -428 687 -335 68 -416 126 -2 -232 484 -400 184 -99 260 -271 262 -185 -154 -134 40 -192 471 -148 -169 -107 401 -122 -164 194 -338 668 133 383 246 487 38 -266 379 -98 86 -22 58 -109 612 -289 52 -412 66 -156 -478 -198 25 -291 332 156 -47 389 -142 -71 -30 219 -736 -178 -442 -397 -105 349 254 70 501 -221 466 -363 -139 -128 346 -25 -114 107 -409 11 226 147 -144 183 -277 383 -2 102 -114 48 46 459 192 -98 240 448 207 -507 325 93 488 -261 10 -245 -11 -164 -40 -343 -191 141 -125 -241 -150 236 -147 -137 370 -77 -509 160 251 73 43 94 139 -296 190 -544 68 -588 205 -333 169 42 145 180 -62 166 -292 120 -288 262 -484 61 -30 195 -95 -241 293 -129 -143 112 161 -83 105 146 -33 -215 -362 155 -51 473 -43 181 -111 287 -115 178 -276 35 -431 496 20 -216 138 -16 -304 -147 7 -170 -104 39 193 64 142 -117 31 -145 61 -59 308 300 -99 135 -380 132 -237 280 -391 -212 1 58 -256 21 76 -19 -62 3 8 109 384 273 16 -6 -177 -94 218 176 -441 326 26 -56 166 259 -155 243 -376 84 -221 432 0 -32 -478 -249 469 -244 106 528 -89 142 -842 -1 -225 -205 -440 -47 -49 -237 -284 -229 -35 -153 14 2 168 156 330 -357 401 6 525 331 -71 -164 54 51 -44 396 -434 -85 -644 342 23 69 -86 91 -45 629 -14 96 -222 21 37 -110 -5 -390 332 -216 -8 12 -31 -96 112 246 -85 533 -104 98 -193 502 -191 308 -98 239 30 228 342 121 426 -542 91 129 205 -3 148 -19 -485 285 -226 -171 34 790 -211 405 -46 -27 -141 335 248 -1 -232 87 221 -152 66 -129 -276 -195 327 -375 45 66 409 579 138 70 -417 116 -110 307 -113 -150 -446 97 -156 111 -444 104 -39 -8 -84 -324 85 -293 -25 -320 -28 -405 289 -298 -70 229 11 -350 -110 -161 -158 36 -4 278 -289 247 112 -119 -304 -428 -106 250 32 123 -16 129 -28 -162 434 -203 632 44 -21 -158 194 9 104 206 -129 407 -243 499 -233 207 -178 392 -72 -42 -95 -170 -221 -357 -197 -359 -345 -192 202 -446 -229 -98 557 -538 -166 -429 -482 -117 456 60 150 -43 -37 188 -431 -127 -427 90 -397 191 189 201 -114 -484 228 -169 554 -384 -106 -81 203 -54 -21 -97 -369 -20 -86 483 -266 103 313 -199 186 346 -242 -98 -395 17 -12 236 2 -281 158 141 384 139 498 44 675 10 239 188 297 174 180 474 407 327 114 449 -24 -339 -384 232 -112 -236 239 -202 44 -135 -49 -403 439 202 91 -227 -326 -271 206 -254 -110 263 -224 60 -673 410 -216 299 -174 91 -33 108 8 349 -69 -104 -81 -260 167 -458 552 -573 -138 143 3 -40 194 238 251 -286 -3 125 -496 105 -402 635 -313 65 -417 131 -2 -235 511 -416 189 -103 262 -280 269 -189 -155 -134 40 -196 475 -150 -170 -106 388 -119 -163 197 -351 684 134 381 247 495 39 -280 395 -102 88 -21 56 -102 562 -268 49 -391 63 -154 -483 -203 26 -298 339 162 -50 419 -156 -78 -33 236 -778 -183 -452 -412 -112 380 277 75 530 -234 493 -388 -149 -138 375 -28 -127 119 -465 12 262 172 -169 213 -323 441 -2 116 -127 53 51 515 216 -110 268 491 221 -530 328 93 486 -265 10 -253 -11 -176 -44 -385 -217 159 -140 -269 -167 258 -158 -146 392 -82 -549 172 273 80 48 107 161 -346 218 -620 77 -666 233 -384 195 48 166 208 -73 193 -338 136 -320 285 -526 66 -33 216 -107 -275 333 -147 -161 124 178 -92 117 162 -37 -240 -407 174 -58 542 -50 212 -130 336 -134 207 -322 41 -505 577 23 -255 163 -19 -360 -174 9 -201 -123 46 227 75 165 -135 35 -166 70 -68 356 344 -120 160 -450 156 -286 342 -453 -262 1 72 -299 25 91 -23 -73 4 10 126 435 310 19 -7 -217 -116 271 219 -551 400 32 -68 202 318 -193 304 -442 104 -275 533 0 -40 -563 -292 582 -300 128