File name: Pandora54s1_Seoul_20230808_L2Fit_fsus1c17d20220516p1-8.txt File generation date: 20230814T050042.2Z Data description: Level 2 spectral fitting results file Data file version: fsus1c17p1-8 Local principal investigator: Jaemin Hong Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 54 Spectrometer number: 1 Processing software version used: BlickP v1.8.49 Instrument operation file used: Pandora54_OF_v4d20200817.txt Instrument calibration file used: Pandora54s1_CF_v17d20220516.txt Level 1 file used: Pandora54s1_Seoul_20230808_L1_smca1c17d20220516p1-8.txt Full location name: Yonsei University/Seoul Short location name: Seoul Country of location: South Korea Location latitude [deg]: 37.5644 Location longitude [deg]: 126.9340 Location altitude [m]: 86 Local noon date: 20230808 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, radiometric temperature correction, matrix method stray light correction (replaced by simple method) Data caveats: 1.8 data preparation: lab analysis with L4 copied from P53, refday 20220826 First and last pixel inside fitting window: 272 417 Nominal wavelengths inside fitting window [nm]: 306.0519 306.1924 306.3329 306.4734 306.6139 306.7544 306.8949 307.0353 307.1758 307.3162 307.4566 307.5970 307.7374 307.8778 308.0182 308.1586 308.2989 308.4393 308.5796 308.7199 308.8602 309.0005 309.1408 309.2811 309.4213 309.5616 309.7018 309.8421 309.9823 310.1225 310.2627 310.4029 310.5430 310.6832 310.8234 310.9635 311.1036 311.2437 311.3838 311.5239 311.6640 311.8041 311.9442 312.0842 312.2242 312.3643 312.5043 312.6443 312.7843 312.9243 313.0642 313.2042 313.3441 313.4841 313.6240 313.7639 313.9038 314.0437 314.1836 314.3235 314.4633 314.6032 314.7430 314.8828 315.0226 315.1624 315.3022 315.4420 315.5818 315.7215 315.8612 316.0010 316.1407 316.2804 316.4201 316.5598 316.6995 316.8391 316.9788 317.1184 317.2580 317.3977 317.5373 317.6769 317.8164 317.9560 318.0956 318.2351 318.3747 318.5142 318.6537 318.7932 318.9327 319.0722 319.2117 319.3511 319.4906 319.6300 319.7694 319.9088 320.0482 320.1876 320.3270 320.4664 320.6057 320.7451 320.8844 321.0237 321.1630 321.3023 321.4416 321.5809 321.7201 321.8594 321.9986 322.1378 322.2771 322.4163 322.5555 322.6946 322.8338 322.9730 323.1121 323.2512 323.3904 323.5295 323.6686 323.8077 323.9467 324.0858 324.2249 324.3639 324.5029 324.6420 324.7810 324.9200 325.0589 325.1979 325.3369 325.4758 325.6148 325.7537 325.8926 326.0315 326.1704 326.3093 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20230808T090623.8Z 8620.379443 6 1 50.07 2 74.08 278.38 125.46 357.88 0.00 1 0.00 1 0 49 2.453e-02 1.174e-03 1.712e-02 1.057e-03 1.984319e-06 3.977788e-07 6.759974e-08 3.890368e-07 1.110525e-05 231.77 -2.00 3.44 -2.00 323.52 0.00e+00 1.763777e-03 1.680782e-04 7.582410e-05 2.375521e-05 2.858800e-03 291.45 -2.00 20.00 -2.00 324.13 0.00e+00 8.106690e-04 2.143485e-04 2.869681e-05 2.584213e-05 5.315577e-03 291.45 -2.00 20.00 -2.00 322.98 0.00e+00 1.085365e-03 4.907440e-04 1.294257e-04 1.725763e-05 5.493981e-03 291.45 -2.00 20.00 -2.00 323.34 0.00e+00 4.470051e-01 2.333435e-03 2.895314e-04 2.451396e-03 3.081086e-02 232.58 1.19 0.00 0.25 52.94 321.50 0.00e+00 -6.511544e-04 2.568521e-04 7.151774e-05 2.578368e-05 8.306807e-04 291.45 -2.00 20.00 -2.00 320.33 0.00e+00 3.582 0.001 303.00 329.40 4 1.2616e+00 4.6504e-03 3.4551e-02 1.9702e-03 9.6210e-02 -7.9315e-02 9.5515e-03 3.9570e-03 3.4935e-04 1.0256e-01 2.7050e-02 4.8390e-03 7.5022e-04 1.8460e-04 5.5562e-02 -2.3338e-02 3.4745e-03 8.4244e-04 2.1506e-04 2.2426e-02 1.1158e-02 1.8342e-03 2.2413e-04 1.2921e-04 1.8241e-02 3.2748e-03 -5.6590e-03 4.2214e-04 9.8361e-05 2.0678e-05 1.0226e-03 -1.7440e-04 3.7448e-05 3.6570e-06 9.4988e-07 7.3750e-04 2.6120e-02 -1.5364e-04 -3.3950e-01 6.6715e-02 1.7970e-03 5.1623e-04 1.3076e+00 11 9 0 11 4 0 83.97 27.24 0.36 0.02612 0.02479 449 88 1 5 0 111.456 30.76 19.97 27.24 45.12 38.9 1084.53 12844 3163 22519 -1722 5825 -1394 -1990 -2252 -189 -711 -333 -2296 -1201 -3431 -387 290 -785 1091 660 308 -3185 -1531 -684 195 133 1339 -1759 -908 -713 -2132 -1939 -456 -168 834 1265 554 758 249 -47 391 -199 -596 181 733 115 682 77 -101 421 201 68 53 -643 -165 -122 265 193 -295 -260 150 46 597 109 -19 62 -164 4 -726 -576 -763 -359 -196 -327 259 266 79 151 -22 -37 112 74 49 -60 71 20 275 83 -18 -67 10 -44 38 71 -28 -163 -18 117 -160 -61 -46 -38 122 19 13 -173 -7 35 -31 -23 -17 240 -18 -44 -147 9 123 73 306 -153 11 59 -10 -75 81 17 27 -46 -157 -50 60 27 -13 72 26 -99 66 4 -25 -71 11 17 -41 76 -86 -31 88 167 48 316 -29 101 -29 -49 -64 -6 -24 -12 -88 -48 -143 -16 12 -37 54 35 16 -167 -77 -35 11 9 96 -137 -68 -53 -180 -193 -49 -21 115 185 84 117 39 -8 62 -32 -98 31 135 23 149 18 -25 107 53 18 14 -166 -44 -35 85 67 -106 -89 49 15 215 45 -9 29 -78 2 -305 -219 -270 -138 -75 -145 132 151 48 98 -15 -27 86 58 38 -45 50 13 170 51 -12 -51 8 -43 40 74 -27 -146 -15 101 -150 -60 -47 -42 142 24 18 -244 -9 46 -38 -27 -20 295 -24 -61 -208 13 164 93 374 -180 13 68 -13 -105 122 27 43 -72 -261 -87 109 50 -23 129 45 -163 115 7 -44 -139 23 38 -102 181 -213 -77 215 SS 20230808T091222.4Z 8620.383593 9 1 50.00 2 75.25 279.24 125.46 359.56 0.00 1 0.00 1 0 49 9.917e-02 3.194e-03 5.299e-02 2.483e-03 1.802309e-06 9.556661e-07 1.037113e-07 3.891105e-07 4.320952e-05 231.77 -2.00 3.44 -2.00 323.76 0.00e+00 2.416459e-03 4.075490e-04 9.199716e-05 2.373541e-05 1.154568e-02 291.45 -2.00 20.00 -2.00 324.42 0.00e+00 3.390788e-04 5.306043e-04 4.433998e-05 2.589819e-05 2.093218e-02 291.45 -2.00 20.00 -2.00 323.20 0.00e+00 2.481981e-03 1.234402e-03 2.714743e-04 1.752793e-05 2.219992e-02 291.45 -2.00 20.00 -2.00 323.58 0.00e+00 4.723035e-01 5.738439e-03 6.175737e-04 2.450365e-03 1.248180e-01 230.14 2.78 0.00 0.24 211.04 321.89 0.00e+00 -8.578880e-04 6.951801e-04 6.691967e-05 2.587248e-05 3.279697e-03 291.45 -2.00 20.00 -2.00 320.77 0.00e+00 3.847 0.001 303.00 329.40 4 2.2773e+00 1.1073e-02 3.7156e-02 1.9708e-03 3.8721e-01 -1.0637e-01 2.3523e-02 5.1298e-03 3.5555e-04 4.1453e-01 2.9972e-02 1.2195e-02 9.4533e-04 1.9900e-04 2.2491e-01 4.1774e-04 9.0982e-03 1.3331e-03 2.3970e-04 8.0983e-02 -3.8102e-03 4.6877e-03 4.8367e-04 1.3778e-04 6.2458e-02 8.9896e-04 -5.1275e-03 9.5063e-04 1.4360e-04 1.9934e-05 1.9015e-03 1.5498e-04 9.2513e-05 4.5194e-06 9.6574e-07 2.9620e-03 1.8350e-02 -9.6249e-05 -3.1075e-01 1.5172e-01 8.6986e-04 5.4374e-04 5.0417e+00 12 8 8 10 0 0 99.72 25.74 0.42 0.01835 0.01953 220 43 1 5 0 227.228 29.47 19.98 25.74 45.21 38.5 1083.97 27203 -50705 53207 -32754 54677 -13419 -3410 -32660 -1995 7732 3695 8303 7662 7180 -11393 8902 -16054 8831 -7684 1804 -14755 1716 -8767 1332 5908 2175 525 -2206 878 -5899 6657 -83 5760 -1313 4364 499 5782 677 550 -525 372 -11 -936 252 -963 3776 -1527 1118 -97 1345 -692 2168 -1210 614 -705 -568 -111 -620 1162 -661 906 -1123 -42 -811 528 -1160 118 -1180 287 -252 -933 447 -742 410 -170 311 -229 379 -123 359 -369 566 -407 125 -80 -554 463 -439 32 -213 351 -288 483 -415 291 -390 297 -192 468 -295 156 -29 -23 140 -124 392 -133 79 -428 351 -171 141 -190 71 19 287 68 342 -627 -99 152 -341 164 -138 316 -128 133 -338 9 65 48 -42 37 -19 -174 158 -32 144 -231 28 -26 91 72 21 -167 101 262 -824 501 -562 553 -246 -67 -866 -46 177 93 213 206 200 -375 257 -632 300 -319 69 -634 62 -358 56 269 115 30 -125 48 -385 454 -7 567 -154 513 63 708 87 72 -70 50 -1 -136 39 -168 680 -311 234 -21 302 -159 473 -270 139 -176 -157 -34 -196 345 -193 264 -363 -15 -330 222 -493 47 -444 96 -79 -295 152 -297 187 -88 174 -135 236 -82 250 -266 404 -283 80 -48 -317 264 -277 23 -173 318 -284 472 -385 245 -307 237 -167 431 -286 159 -32 -27 181 -167 519 -168 94 -484 395 -203 177 -254 96 24 363 84 400 -712 -107 167 -417 221 -201 481 -203 221 -601 17 125 94 -82 71 -35 -303 267 -57 271 -478 57 -57 220 183 54 -442 267 SS 20230808T091740.4Z 8620.387273 12 1 50.00 2 76.29 280.00 125.44 1.04 0.00 1 0.00 1 0 65 6.740e-02 1.812e-03 3.734e-02 1.546e-03 2.566293e-06 5.989519e-07 5.947135e-08 3.891710e-07 3.005666e-05 231.77 -2.00 3.44 -2.00 323.82 0.00e+00 2.793884e-03 2.578008e-04 1.169910e-04 2.372743e-05 7.854808e-03 291.45 -2.00 20.00 -2.00 324.57 0.00e+00 7.012556e-04 3.370217e-04 3.547842e-05 2.596906e-05 1.446914e-02 291.45 -2.00 20.00 -2.00 323.24 0.00e+00 9.683032e-04 7.923081e-04 2.858234e-04 1.794004e-05 1.510305e-02 291.45 -2.00 20.00 -2.00 323.66 0.00e+00 5.091940e-01 3.689975e-03 8.571765e-04 2.450239e-03 8.482662e-02 232.33 1.65 0.00 0.22 144.37 322.03 0.00e+00 -8.037987e-04 4.659120e-04 1.594698e-04 2.587598e-05 2.234973e-03 291.45 -2.00 20.00 -2.00 320.93 0.00e+00 4.118 0.001 303.00 329.40 4 1.3214e+00 7.1762e-03 3.9732e-02 1.9706e-03 2.6389e-01 -8.9170e-02 1.5279e-02 6.0477e-03 3.5352e-04 2.8151e-01 3.7033e-02 7.8803e-03 1.1752e-03 2.1162e-04 1.5293e-01 -2.0444e-02 5.9774e-03 1.2554e-03 2.7339e-04 5.9597e-02 4.8213e-03 3.0793e-03 5.0936e-04 1.5196e-04 4.7499e-02 1.7741e-03 -6.2678e-03 4.4220e-04 1.3313e-04 1.9173e-05 1.8020e-03 -2.0112e-04 5.8026e-05 6.1094e-06 9.7970e-07 2.0182e-03 1.5862e-02 -1.5266e-04 -2.4924e-01 9.0054e-02 2.3081e-03 5.4188e-04 3.2676e+00 12 8 8 10 0 0 91.76 24.93 0.33 0.01586 0.01433 327 64 1 5 0 152.898 28.73 19.98 24.93 44.95 38.3 1081.41 -9836 54293 25584 -5781 -24946 6711 -28549 15342 -8420 7890 -7567 1337 3154 -6376 -1811 5349 -465 -1151 -1619 -5941 -2028 -2627 4110 -5242 7074 -2683 -1340 -2814 -1231 -3195 2967 -1644 1826 2550 618 1336 -109 460 -2078 146 -1526 77 -831 1857 -1046 163 -860 22 505 1785 1998 538 253 -326 601 661 413 -550 839 104 836 491 -275 -392 -340 -271 -122 -518 -1404 -277 -339 293 -282 472 126 -75 -191 -294 117 42 -97 -4 218 -404 -153 -293 303 -89 155 63 53 -20 187 -137 -283 -193 91 53 -27 283 -279 223 -98 103 -68 162 73 -134 -143 50 107 10 -76 -36 180 277 135 1 -22 -150 -264 -234 -29 144 148 -31 16 -32 -135 1 -31 -16 -32 81 -32 109 -125 -61 -58 41 95 -72 96 -136 72 13 -101 445 247 -68 -351 87 -543 245 -179 159 -184 32 78 -176 -49 142 -14 -38 -56 -218 -70 -89 137 -213 294 -124 -66 -150 -65 -172 178 -125 158 245 65 144 -12 51 -243 17 -183 9 -107 254 -163 27 -157 4 100 362 406 109 50 -67 134 165 114 -160 231 28 228 146 -95 -150 -136 -108 -46 -182 -452 -82 -101 95 -107 206 62 -41 -109 -178 75 28 -67 -3 146 -254 -89 -163 169 -55 109 50 47 -19 183 -126 -238 -150 72 45 -25 270 -284 241 -117 133 -91 217 93 -162 -164 58 129 12 -103 -48 237 353 167 2 -25 -165 -296 -290 -40 214 234 -50 26 -55 -240 2 -58 -30 -57 141 -54 190 -206 -109 -113 88 221 -180 253 -374 199 35 SS 20230808T092349.6Z 8620.391546 15 1 50.15 2 77.49 280.89 125.38 2.76 0.00 1 0.00 1 0 98 8.905e-02 2.056e-03 5.651e-02 2.054e-03 2.166829e-06 8.067614e-07 7.499148e-08 3.892469e-07 3.907485e-05 231.77 -2.00 3.44 -2.00 323.98 0.00e+00 2.590989e-03 3.511133e-04 1.133963e-04 2.370827e-05 1.042460e-02 291.45 -2.00 20.00 -2.00 324.74 0.00e+00 4.322282e-04 4.702971e-04 4.546522e-05 2.606402e-05 1.873280e-02 291.45 -2.00 20.00 -2.00 323.39 0.00e+00 1.470772e-03 1.116802e-03 3.598850e-04 1.834784e-05 1.998819e-02 291.45 -2.00 20.00 -2.00 323.81 0.00e+00 5.469220e-01 5.126991e-03 1.023190e-03 2.449158e-03 1.124020e-01 232.30 2.14 0.00 0.20 189.10 322.34 0.00e+00 -8.622694e-04 7.025699e-04 1.730697e-04 2.593249e-05 2.926107e-03 291.45 -2.00 20.00 -2.00 321.29 0.00e+00 4.484 0.001 303.00 329.40 4 1.3988e+00 9.9069e-03 4.3288e-02 1.9711e-03 3.5002e-01 -1.0868e-01 2.1411e-02 6.8879e-03 3.5792e-04 3.7211e-01 4.7588e-02 1.1155e-02 1.6594e-03 2.3805e-04 2.0309e-01 -2.5974e-02 8.8351e-03 1.4958e-03 3.1797e-04 8.3648e-02 7.2162e-03 4.4873e-03 5.8793e-04 1.6852e-04 5.9647e-02 1.1373e-03 -7.6819e-03 4.4853e-04 1.2037e-04 1.9429e-05 2.6645e-03 -2.6744e-04 7.9912e-05 7.9166e-06 1.0060e-06 2.6702e-03 1.3425e-02 -1.7003e-04 -3.6395e-01 1.1300e-01 1.7429e-03 5.2246e-04 4.0995e+00 12 8 8 10 0 0 88.06 24.28 0.31 0.01343 0.01138 252 49 1 5 0 198.950 28.10 19.99 24.28 44.76 38.1 1080.64 11879 -25697 -24055 51123 -20911 -53760 -10966 -7206 39754 -9324 -14911 3334 -4916 11905 12016 1901 -2024 12312 -11222 10529 -4268 -2591 -6906 -2756 952 3985 4715 -4826 7289 3045 663 -2852 2460 -2484 2114 -1897 4383 839 -78 -868 -2279 -543 -891 1701 -1171 1937 -1977 1388 -282 756 1160 999 -336 1343 919 1147 580 -436 160 -794 575 -338 312 -226 75 -609 -59 -71 -134 445 -13 420 -410 195 -508 -16 -94 50 -752 168 36 -92 -93 -433 -2 119 99 -273 36 209 152 -385 319 4 -115 -213 325 -417 186 288 -63 235 -128 156 58 -237 52 266 -135 109 -31 72 14 -78 68 32 202 65 -200 -141 -65 -152 10 0 212 -118 72 -162 -52 115 -69 -81 86 63 -140 134 -99 -11 -159 79 30 58 17 28 -116 66 102 -265 -257 428 -240 -826 -149 -108 503 -169 -299 62 -101 225 229 41 -48 285 -328 264 -117 -69 -199 -87 33 152 192 -208 285 136 35 -173 168 -199 173 -169 376 75 -7 -82 -224 -55 -95 193 -152 266 -305 220 -47 131 201 170 -57 231 173 242 137 -109 39 -189 138 -90 95 -76 26 -215 -20 -22 -38 117 -3 122 -141 77 -230 -8 -49 27 -446 104 23 -58 -57 -250 -1 61 52 -158 24 157 129 -358 297 3 -92 -157 242 -340 160 260 -60 242 -146 194 76 -309 65 313 -152 122 -37 91 18 -104 87 40 243 75 -223 -152 -71 -186 14 0 333 -193 124 -275 -94 211 -128 -152 157 118 -252 233 -177 -21 -312 170 70 146 46 78 -330 187 SS 20230808T093445.3Z 8620.399136 18 1 50.24 2 79.61 282.46 125.19 5.81 0.00 1 0.00 1 0 113 2.214e-01 5.770e-03 1.863e-01 3.928e-03 2.444593e-06 1.649293e-06 1.099689e-06 3.893462e-07 9.527309e-05 231.77 -2.00 3.44 -2.00 324.32 0.00e+00 5.523376e-03 7.367640e-04 3.187831e-04 2.379938e-05 2.577195e-02 291.45 -2.00 20.00 -2.00 325.10 0.00e+00 2.044770e-03 1.016600e-03 3.940633e-04 2.627123e-05 4.644750e-02 291.45 -2.00 20.00 -2.00 323.72 0.00e+00 6.205960e-03 2.363449e-03 1.076422e-03 1.891949e-05 4.954376e-02 291.45 -2.00 20.00 -2.00 324.16 0.00e+00 6.122461e-01 1.024347e-02 2.056928e-03 2.447815e-03 2.799478e-01 221.52 3.76 0.00 0.18 467.02 322.87 0.00e+00 -4.201692e-03 1.643539e-03 2.894429e-03 2.644016e-05 7.264767e-03 291.45 -2.00 20.00 -2.00 321.90 0.00e+00 5.318 0.002 303.00 329.40 4 1.5228e+00 1.8931e-02 5.2810e-02 1.9700e-03 8.6344e-01 -1.3604e-01 4.1181e-02 3.8827e-02 3.7792e-04 9.2468e-01 -1.5355e-01 2.7451e-02 1.0053e-02 1.7455e-04 5.0406e-01 2.4774e-01 2.3398e-02 1.2055e-02 1.6230e-04 1.6949e-01 -1.0122e-01 1.0268e-02 5.5147e-03 1.0336e-04 1.2887e-01 4.3648e-04 8.9496e-03 2.4220e-03 4.5350e-08 3.8329e-10 1.7828e-07 -2.7297e-04 1.6605e-04 1.4885e-05 1.0620e-06 6.6524e-03 1.1142e-02 -1.7954e-04 1.4133e-01 1.9704e-01 4.1136e-02 6.4840e-04 8.9185e+00 12 8 8 10 0 0 83.07 23.64 0.40 0.01114 0.00906 150 29 1 5 0 334.844 27.67 19.99 23.64 44.61 37.8 1079.09 -109373 57659 -108679 58456 -102127 93545 -48307 -25294 -20413 15480 -6940 -35432 8461 -18179 -17535 -37408 25209 -40289 29863 -24248 7641 -24016 11628 -19714 24175 2734 3170 8504 -6778 -704 5032 10683 998 20252 3676 21672 615 14053 -779 6846 5357 5287 2417 -321 5617 -4431 9803 -1349 12165 2621 8059 2090 5653 808 1727 869 9 3381 -2110 4374 -3846 2740 -881 1343 -2379 2086 -670 -298 -1428 -1600 -1801 -1159 5 -1211 1370 -882 122 -2191 527 -1815 -659 -562 -793 -1061 -1806 -1009 -1058 755 -973 500 -984 468 -433 252 -1283 352 -12 414 376 334 -123 5 738 114 506 -132 914 -71 314 -168 845 -92 -27 144 434 726 242 669 -947 51 -342 551 -504 328 -181 -122 -180 -225 -314 -169 301 -163 166 -222 -22 -308 510 -353 -2 -342 339 -51 -67 -46 86 134 -1332 215 -1654 217 -1658 348 -621 -299 -269 141 -92 -695 100 -301 -285 -810 319 -1117 422 -590 119 -512 186 -487 468 71 89 216 -202 -22 177 441 55 1034 239 1202 43 841 -55 452 368 379 190 -29 528 -507 1054 -174 1436 356 1033 276 700 107 248 142 2 638 -412 785 -778 569 -220 364 -702 585 -183 -75 -329 -347 -400 -285 1 -416 524 -381 55 -982 244 -904 -333 -283 -422 -531 -858 -461 -498 392 -546 318 -724 373 -352 192 -901 243 -8 311 276 258 -102 5 730 126 589 -156 1034 -77 325 -175 913 -106 -32 175 506 814 265 700 -1064 55 -379 624 -653 463 -274 -194 -302 -405 -597 -329 595 -325 320 -407 -38 -517 876 -662 -4 -777 836 -137 -192 -140 265 417 SS 20230808T094824.2Z 8620.408614 23 1 50.46 2 82.24 284.44 124.79 9.57 0.00 1 0.00 1 0 193 1.516e-01 1.607e-02 3.613e-01 1.553e-02 9.127556e-06 7.128570e-06 8.951526e-07 3.894568e-07 6.511390e-05 231.77 -2.00 3.44 -2.00 324.58 0.00e+00 1.147882e-02 3.188308e-03 3.773830e-04 2.403943e-05 1.763842e-02 291.45 -2.00 20.00 -2.00 325.37 0.00e+00 1.187343e-02 4.818490e-03 7.448609e-04 2.651071e-05 3.168961e-02 291.45 -2.00 20.00 -2.00 323.99 0.00e+00 7.134730e-03 1.049069e-02 7.532551e-04 2.041886e-05 3.391121e-02 291.45 -2.00 20.00 -2.00 324.44 0.00e+00 7.137584e-01 4.159570e-02 3.150545e-03 2.445590e-03 1.935405e-01 206.13 12.90 0.00 0.16 324.96 323.38 0.00e+00 -1.676410e-02 7.701294e-03 3.893145e-03 2.643197e-05 5.111070e-03 291.45 -2.00 20.00 -2.00 322.55 0.00e+00 6.888 0.005 303.00 329.40 4 1.8048e+00 8.5345e-02 6.8482e-02 1.9708e-03 6.0074e-01 4.3644e-01 1.6707e-01 3.6937e-02 4.0094e-04 6.3927e-01 -9.8172e-01 8.8512e-02 1.3421e-02 1.6879e-04 3.4882e-01 7.7676e-01 4.5777e-02 8.1752e-03 1.0473e-04 1.1706e-01 -2.2639e-01 3.1015e-02 4.2357e-03 7.4223e-05 8.6931e-02 5.9475e-05 1.4033e-01 2.6670e-02 1.8837e-08 7.3038e-11 1.6144e-07 -4.3453e-04 7.3323e-04 1.5336e-05 1.0870e-06 4.5480e-03 1.0594e-02 -1.9751e-04 5.7904e-01 6.5727e-01 2.8119e-02 4.8886e-04 4.9557e+00 12 8 8 10 0 0 78.28 23.31 0.60 0.01059 0.00728 45 9 1 5 0 1121.186 27.35 20.00 23.31 44.10 37.6 1075.18 32411 5999 29510 15745 31817 18509 31012 31105 20026 34139 1231 8813 -1599 37896 -7708 23146 -11651 27501 10533 18482 -20734 -18870 -22237 -36056 6869 -7834 9725 -47435 -5035 -45473 13999 251 40585 41890 31061 22476 20793 11971 7096 25800 2202 -1152 -15378 11233 6489 11274 18453 13168 1279 23012 12756 14479 -8595 -27224 5399 -24767 22868 -13845 15318 -1424 2062 -3392 2288 5063 9710 1572 -1853 -2775 -13848 -3025 -19254 971 -9830 13742 -8716 12075 2341 8656 3112 -668 3107 2457 1974 -8601 967 -10373 1945 -3645 1313 1672 6828 1582 4725 -4436 -753 -2329 -1599 561 -1452 3093 -986 1612 -656 2629 -1113 1307 -2349 2572 293 -1678 -2010 -1501 584 -602 1408 -1234 2062 -1542 -214 -2299 480 -252 -559 261 491 497 -708 -249 -1277 1309 -617 976 -396 1650 -363 856 -862 -221 -422 336 974 -471 713 -652 315 -434 477 260 631 479 468 541 681 823 809 825 67 350 -69 557 -257 340 -568 444 337 319 -824 -423 -460 -1465 101 -216 143 -3091 -74 -2879 206 12 861 1186 1287 1067 884 524 311 540 97 -58 -1123 550 431 787 1282 1125 143 1853 1181 1144 -883 -3515 451 -3841 1973 -2242 1537 -181 267 -540 404 978 1843 325 -366 -492 -2456 -423 -3481 155 -2254 2870 -2799 3401 772 2795 1138 -266 1202 942 724 -3303 315 -3822 657 -1518 618 912 4080 1112 3244 -3145 -458 -1310 -887 329 -928 1978 -711 1229 -581 2538 -1192 1408 -2573 2553 286 -1680 -2118 -1666 661 -684 1500 -1314 2061 -1544 -206 -2196 463 -282 -724 369 751 802 -1230 -463 -2513 2573 -1254 1981 -784 2999 -640 1440 -1531 -422 -896 784 2463 -1339 2132 -2091 1031 -1446