File name: Pandora240s1_Thessaloniki_20240918_L2Fit_fwvt1c13d20231018p1-8.txt File generation date: 20241007T200210.6Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c13p1-8 Local principal investigator: Alkiviadis Bais Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 240 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora240_OF_v2d20220707.txt Instrument calibration file used: Pandora240s1_CF_v13d20231018.txt Level 1 file used: Pandora240s1_Thessaloniki_20240918_L1_smca1c13d20231018p1-8.txt Full location name: Thessaloniki Short location name: Thessaloniki Country of location: Greece Location latitude [deg]: 40.6336 Location longitude [deg]: 22.9561 Location altitude [m]: 60 Local noon date: 20240918 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are blind pixel subtraction, dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: Based on session 12 for VP 20231018 First and last pixel inside fitting window: 1620 1769 Nominal wavelengths inside fitting window [nm]: 492.0819 492.2027 492.3235 492.4443 492.5651 492.6859 492.8066 492.9273 493.0480 493.1687 493.2894 493.4101 493.5307 493.6513 493.7719 493.8925 494.0131 494.1336 494.2541 494.3746 494.4951 494.6156 494.7361 494.8565 494.9769 495.0974 495.2177 495.3381 495.4585 495.5788 495.6991 495.8194 495.9397 496.0600 496.1802 496.3005 496.4207 496.5409 496.6611 496.7812 496.9014 497.0215 497.1416 497.2617 497.3818 497.5018 497.6219 497.7419 497.8619 497.9819 498.1018 498.2218 498.3417 498.4616 498.5815 498.7014 498.8213 498.9411 499.0609 499.1807 499.3005 499.4203 499.5401 499.6598 499.7795 499.8992 500.0189 500.1386 500.2582 500.3778 500.4975 500.6171 500.7366 500.8562 500.9757 501.0953 501.2148 501.3343 501.4537 501.5732 501.6926 501.8120 501.9314 502.0508 502.1702 502.2895 502.4088 502.5281 502.6474 502.7667 502.8860 503.0052 503.1244 503.2436 503.3628 503.4820 503.6011 503.7203 503.8394 503.9585 504.0775 504.1966 504.3156 504.4347 504.5537 504.6726 504.7916 504.9106 505.0295 505.1484 505.2673 505.3862 505.5050 505.6239 505.7427 505.8615 505.9803 506.0991 506.2178 506.3366 506.4553 506.5740 506.6927 506.8113 506.9300 507.0486 507.1672 507.2858 507.4044 507.5229 507.6414 507.7600 507.8785 507.9969 508.1154 508.2338 508.3523 508.4707 508.5891 508.7074 508.8258 508.9441 509.0624 509.1807 509.2990 509.4173 509.5355 509.6537 509.7720 509.8901 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-251: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 252-401: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20240918T083918.4Z 9027.360630 361 1 55.02 2 45.43 142.48 132.93 318.75 0.00 1 0.00 1 0 15 4.948e-03 4.922e-03 1.275e-03 1.268e-03 3.339727e+03 7.442136e+01 2.555310e+02 -6.000000e+00 2.593664e+02 287.40 -2.00 20.00 -2.00 505.20 0.00e+00 5.455619e-04 3.424381e-05 3.550213e-05 -6.000000e+00 1.367612e-04 287.40 -2.00 20.00 -2.00 500.20 0.00e+00 -8.516762e-02 2.455189e-02 1.805415e-02 -6.000000e+00 9.492478e-02 228.82 -2.00 3.50 -2.00 501.81 0.00e+00 1.423 0.000 489.00 513.00 1 7.7448e+00 1.8736e-03 2.7064e-03 -6.0000e+00 7.2510e-03 1.1736e-02 5.0064e-04 4.8345e-04 -6.0000e+00 1.9377e-03 6.8954e-04 5.6018e-04 8.4971e-05 2.4160e-05 -6.0000e+00 3.4291e-04 6.2443e-03 -7.6887e-05 12 8 8 10 0 0 97.68 24.01 2.21 0.00624 0.01013 15 2 1 2 0 3667.435 19.99 24.01 23.60 28.00 28.25 31.0 947.17 -871 -905 -39 -56 238 540 889 1326 789 669 369 274 -229 -198 -527 -93 -348 292 277 25 428 153 41 476 257 536 523 796 -640 -651 -561 -950 -895 154 209 73 -14 -194 -335 -514 -117 -63 91 289 293 180 438 490 526 -221 -601 -999 -1277 -911 -521 -361 -139 -34 14 161 -110 311 278 606 68 45 190 -59 -179 -553 -582 -133 -338 351 128 263 -216 -413 -501 -688 -583 -520 -388 -242 -167 81 -360 -108 -379 -183 -333 280 388 740 721 584 464 -111 -852 -1044 -981 -924 -779 105 -272 -65 -56 -321 -562 -436 72 35 99 321 463 581 814 888 419 489 443 -84 311 348 201 86 184 263 682 502 108 571 -87 -432 -1219 -248 -139 -260 34 112 328 315 308 414 691 392 67 -190 -708 -497 -862 -912 -41 -59 252 583 977 1463 871 722 394 291 -238 -202 -540 -96 -363 311 295 27 455 164 44 505 277 574 556 843 -689 -663 -570 -978 -927 160 227 79 -15 -204 -348 -528 -120 -66 96 305 314 194 464 511 541 -222 -606 -989 -1249 -895 -530 -366 -144 -35 14 165 -113 323 290 628 70 46 189 -58 -176 -531 -576 -128 -328 343 128 261 -208 -392 -471 -644 -548 -499 -372 -232 -164 81 -358 -106 -375 -181 -332 281 385 733 696 578 452 -105 -788 -946 -888 -849 -739 100 -270 -64 -54 -306 -548 -412 70 34 98 320 462 580 820 868 421 482 431 -80 291 332 194 83 177 253 644 480 103 526 -80 -395 -1101 -225 -131 -250 32 106 311 298 294 398 662 376 63 -179 -656 -458 SQ 20240918T084845.5Z 9027.367193 365 1 54.12 2 44.38 145.48 133.99 321.50 0.00 1 0.00 1 0 15 4.242e-03 4.218e-03 3.239e-04 3.226e-04 2.663469e+03 1.853196e+01 2.038547e+02 -6.000000e+00 2.223818e+02 287.40 -2.00 20.00 -2.00 505.21 0.00e+00 5.026982e-04 8.715412e-06 3.264124e-05 -6.000000e+00 1.172442e-04 287.40 -2.00 20.00 -2.00 500.22 0.00e+00 -1.447940e-01 6.232748e-03 1.514871e-02 -6.000000e+00 8.137120e-02 228.82 -2.00 3.50 -2.00 501.83 0.00e+00 1.397 0.000 489.00 513.00 1 5.0929e+00 4.7607e-04 2.5094e-03 -6.0000e+00 6.2160e-03 9.7053e-03 1.2721e-04 4.0074e-04 -6.0000e+00 1.6607e-03 9.8760e-03 1.2282e-04 2.1635e-05 2.0441e-05 -6.0000e+00 2.9392e-04 8.2350e-03 -7.5167e-05 11 8 0 10 0 0 99.76 24.01 2.13 0.00823 0.00909 245 27 1 2 0 220.522 19.99 24.01 24.05 28.00 28.25 31.0 948.98 -785 -708 58 -41 318 616 794 773 743 550 612 301 -227 -174 -351 -309 -281 70 195 66 266 47 26 368 299 415 588 492 -471 -385 -664 -835 -796 233 78 54 88 -103 -280 -413 -230 -139 40 297 446 292 570 406 336 -305 -457 -823 -994 -904 -545 -256 -31 -39 -82 -72 -118 361 197 518 243 161 115 42 -178 -558 -364 -282 -257 142 155 20 -90 -245 -413 -681 -418 -389 -396 -189 -163 40 -276 -187 -280 -169 -400 238 420 424 588 430 305 -26 -554 -878 -956 -818 -631 159 46 124 56 -353 -518 -314 -147 -115 59 342 289 533 646 724 442 494 297 73 51 430 97 199 480 322 473 754 97 -16 -71 -364 -839 -466 -228 -67 16 161 66 138 300 487 598 424 202 -347 -435 -602 -798 -705 60 -43 336 663 872 828 793 594 653 320 -236 -177 -359 -318 -292 74 209 71 284 51 28 394 324 448 629 526 -489 -390 -675 -859 -824 244 82 59 94 -110 -293 -426 -238 -145 43 316 464 305 589 427 349 -310 -460 -814 -971 -889 -537 -261 -32 -40 -83 -74 -123 365 201 525 245 165 116 42 -176 -540 -349 -274 -252 140 156 20 -87 -235 -392 -644 -397 -377 -384 -183 -162 39 -268 -180 -271 -164 -390 234 425 430 581 420 292 -25 -520 -807 -881 -765 -608 155 45 121 56 -344 -495 -303 -144 -112 58 337 287 527 645 728 439 482 286 69 48 420 92 189 457 305 457 712 92 -15 -66 -339 -771 -432 -213 -63 15 156 64 135 285 466 572 405 195 -325 -397 -549 SQ 20240918T090430.4Z 9027.378129 372 1 53.31 2 42.80 150.71 135.59 326.28 0.00 1 0.00 1 0 15 4.840e-03 4.804e-03 1.677e-03 1.663e-03 4.232592e+03 1.006388e+02 3.117084e+02 -6.000000e+00 2.537468e+02 287.40 -2.00 20.00 -2.00 505.18 0.00e+00 5.380638e-04 4.489564e-05 3.676320e-05 -6.000000e+00 1.337831e-04 287.40 -2.00 20.00 -2.00 500.05 0.00e+00 -1.428160e-01 3.241819e-02 2.359099e-02 -6.000000e+00 9.285178e-02 228.82 -2.00 3.50 -2.00 501.69 0.00e+00 1.361 0.000 489.00 513.00 1 8.0631e+00 2.4773e-03 2.9573e-03 -6.0000e+00 7.0930e-03 1.5206e-02 6.5894e-04 6.0975e-04 -6.0000e+00 1.8951e-03 5.0736e-04 3.1256e-04 1.1079e-04 2.9435e-05 -6.0000e+00 3.3539e-04 7.2767e-03 -7.1642e-05 12 8 8 10 0 0 99.90 24.01 2.31 0.00728 0.00944 26 3 1 2 0 2049.859 20.01 24.01 25.26 28.00 28.25 31.4 956.16 -557 -1043 -153 -46 190 727 619 1226 829 311 790 159 -538 -104 -588 -354 -300 289 224 189 205 -8 79 536 401 400 502 467 -514 -411 -759 -842 -548 231 -42 80 112 -8 -482 -266 -211 -358 205 215 343 578 648 331 436 -404 -309 -711 -832 -958 -606 1 -530 194 -165 -6 -128 277 122 207 365 -145 359 43 -298 -704 -58 -476 -306 31 299 762 -505 -356 -544 -900 -364 -171 -489 -308 90 7 -584 -487 -234 -213 -73 305 674 395 479 623 259 -198 -573 -863 -1120 -1163 -682 130 234 -77 431 -626 -829 -318 -234 -116 354 146 266 544 692 834 314 673 527 -29 95 463 -13 462 282 844 540 678 450 -78 -101 -220 -789 -566 -185 69 -112 153 9 -164 244 479 420 444 336 -418 -506 -753 -563 -1077 -163 -49 203 789 687 1364 922 339 848 170 -566 -107 -608 -368 -315 311 250 212 229 -9 88 597 453 450 560 520 -556 -420 -777 -872 -569 252 -46 85 118 -8 -526 -285 -228 -390 213 226 364 614 680 343 445 -404 -313 -706 -815 -947 -621 1 -547 201 -170 -6 -131 285 127 214 374 -147 353 42 -290 -670 -58 -455 -295 30 295 744 -484 -334 -507 -835 -338 -162 -465 -292 87 7 -575 -476 -229 -209 -71 302 685 403 475 608 248 -184 -519 -767 -998 -1054 -636 127 226 -74 428 -585 -800 -309 -221 -110 340 142 259 528 679 826 309 647 499 -27 87 431 -12 429 264 784 497 630 418 -70 -89 -195 -691 -501 -170 64 -105 146 9 -158 236 465 409 430 319 -386 -456 -677 SQ 20240918T102838.0Z 9027.436551 419 1 52.59 2 39.08 182.56 140.21 355.59 0.00 1 0.00 1 0 15 4.751e-03 4.732e-03 1.436e-03 1.427e-03 3.941530e+03 8.531578e+01 2.935253e+02 -6.000000e+00 2.491184e+02 287.39 -2.00 20.00 -2.00 505.20 0.00e+00 7.000204e-04 3.860431e-05 4.683057e-05 -6.000000e+00 1.313020e-04 287.39 -2.00 20.00 -2.00 500.14 0.00e+00 -1.101101e-01 2.777559e-02 2.243951e-02 -6.000000e+00 9.110500e-02 228.81 -2.00 3.50 -2.00 501.76 0.00e+00 1.287 0.000 489.00 513.00 1 7.9262e+00 2.1214e-03 2.8896e-03 -6.0000e+00 6.9604e-03 1.4171e-02 5.6552e-04 5.7358e-04 -6.0000e+00 1.8585e-03 5.8549e-04 -2.4661e-04 9.5888e-05 2.7745e-05 -6.0000e+00 3.2925e-04 4.8417e-03 -2.6167e-05 12 8 8 10 0 0 73.96 24.02 2.26 0.00484 0.00313 15 2 1 2 0 3505.651 19.99 24.02 27.13 28.00 28.25 31.2 964.59 -1077 -899 220 106 759 410 790 1354 724 649 667 349 -407 89 -394 -216 -364 171 227 -153 290 8 -54 328 297 206 509 621 -552 -444 -804 -944 -1041 33 240 261 -75 -1 -327 -477 -212 -19 -26 207 363 247 701 229 416 -329 -510 -888 -868 -772 -610 -15 -72 -95 -12 40 -112 52 246 332 162 63 119 66 -192 -621 -337 -420 -440 235 228 408 -402 -406 -413 -575 -362 -450 -413 -69 -111 -233 -87 -212 -271 -50 -330 176 210 390 724 589 360 -68 -787 -1298 -979 -607 -810 426 236 1 11 -181 -478 -259 -88 -182 -61 224 249 591 655 791 179 657 259 -203 -137 564 5 150 613 221 801 610 98 464 105 -262 -1248 -511 -363 -12 -134 134 275 167 170 412 542 508 414 -326 -277 -353 -1083 -919 232 112 807 447 878 1508 807 708 718 374 -428 92 -408 -224 -382 184 244 -164 310 8 -58 351 322 222 544 661 -572 -455 -825 -980 -1089 34 262 282 -80 -1 -341 -492 -219 -19 -27 220 390 266 744 240 430 -333 -518 -886 -852 -764 -599 -16 -75 -99 -13 41 -116 54 258 347 168 64 119 65 -189 -598 -320 -406 -429 231 228 405 -389 -387 -389 -538 -340 -432 -397 -66 -109 -232 -86 -209 -268 -49 -328 170 208 386 696 558 349 -64 -725 -1173 -883 -555 -767 404 233 1 10 -172 -446 -243 -85 -177 -61 222 248 587 657 768 180 644 251 -193 -128 535 5 143 585 211 751 579 94 425 96 -238 -1121 -462 -341 -11 -129 126 259 157 161 393 516 482 386 -307 -254 -323 SQ 20240918T111734.4Z 9027.470537 446 1 55.17 2 41.03 201.38 139.25 13.61 0.00 1 0.00 1 0 15 5.017e-03 4.977e-03 1.387e-03 1.379e-03 3.499305e+03 8.162389e+01 2.671785e+02 -6.000000e+00 2.630631e+02 287.39 -2.00 20.00 -2.00 505.20 0.00e+00 7.331537e-04 3.720354e-05 4.449191e-05 -6.000000e+00 1.386710e-04 287.39 -2.00 20.00 -2.00 500.16 0.00e+00 -1.410029e-01 2.680781e-02 1.932013e-02 -6.000000e+00 9.622523e-02 228.81 -2.00 3.50 -2.00 501.78 0.00e+00 1.324 0.000 489.00 513.00 1 7.9291e+00 2.0469e-03 2.7407e-03 -6.0000e+00 7.3514e-03 1.4607e-02 5.4617e-04 5.0626e-04 -6.0000e+00 1.9632e-03 5.8226e-04 -3.3325e-04 9.2633e-05 2.5786e-05 -6.0000e+00 3.4768e-04 4.5183e-03 -3.1734e-05 12 8 8 10 0 0 56.76 24.03 2.26 0.00452 0.00221 14 2 1 2 0 3939.943 20.00 24.03 28.23 28.00 28.25 31.0 967.45 -948 -739 -34 -201 128 574 796 1362 958 527 454 281 -140 -228 -538 142 -174 207 54 -29 146 159 215 413 356 479 819 342 -448 -552 -730 -687 -908 130 379 170 -74 -79 -456 -751 -330 -70 -172 395 383 336 555 480 439 -646 -474 -547 -1184 -935 -837 -343 -70 141 -250 262 -125 492 276 331 190 155 154 108 -236 -670 -492 -304 -320 172 374 398 -238 -504 -583 -754 -517 -383 -330 -339 -172 -168 -109 -164 -154 -119 -187 405 659 366 674 546 352 -53 -695 -1425 -754 -863 -699 350 -135 -119 575 -426 -544 -530 -224 -410 -56 355 348 236 698 724 588 541 174 -144 178 624 72 169 55 577 1101 941 -29 399 -156 -270 -771 -751 -165 43 162 348 52 182 541 388 579 402 29 -545 -685 -583 -952 -754 -35 -214 137 626 885 1456 1024 577 491 302 -147 -235 -557 147 -183 224 58 -31 157 172 230 442 386 517 875 366 -466 -566 -749 -712 -949 136 414 185 -79 -84 -478 -778 -343 -73 -181 420 413 349 592 505 455 -658 -462 -544 -1169 -928 -827 -351 -73 148 -263 270 -130 513 290 334 198 158 155 107 -234 -649 -470 -295 -313 169 375 397 -231 -483 -552 -711 -489 -369 -319 -327 -170 -161 -105 -162 -153 -113 -179 392 654 366 654 522 330 -51 -646 -1302 -685 -797 -665 335 -134 -117 557 -408 -510 -503 -217 -404 -56 356 335 228 678 710 570 535 170 -139 167 596 70 162 53 554 1039 898 -28 370 -143 -247 -695 -686 -156 40 151 328 49 173 516 373 556 385 28 -498 -635 -538 SQ 20240918T161813.4Z 9027.679322 618 1 53.97 2 88.30 270.50 96.45 83.32 0.00 1 0.00 1 0 22 1.428e-02 1.397e-02 4.750e-04 4.734e-04 2.397416e+04 3.365649e+01 1.607345e+03 -6.000000e+00 7.493182e+02 287.36 -2.00 20.00 -2.00 505.39 0.00e+00 6.499061e-03 1.282482e-05 4.009723e-04 -6.000000e+00 3.947525e-04 287.36 -2.00 20.00 -2.00 500.89 0.00e+00 -2.562025e-01 8.957938e-03 1.350151e-01 -6.000000e+00 2.738267e-01 228.78 -2.00 3.50 -2.00 502.39 0.00e+00 16.765 0.087 489.00 513.00 1 3.5090e+00 6.8189e-04 3.0752e-02 -6.0000e+00 2.0923e-02 -3.5024e-02 1.7723e-04 3.6627e-03 -6.0000e+00 5.5828e-03 4.8778e-03 -1.0594e-03 2.8632e-05 1.5604e-04 -6.0000e+00 9.9054e-04 -5.3148e-03 7.0250e-05 12 8 8 10 0 0 97.80 23.97 3.94 -0.00531 -0.01266 151 16 1 2 0 357.046 19.99 23.97 27.24 28.00 28.00 31.4 964.85 -357 183 1560 2245 2730 3117 3573 3265 3231 2393 2080 1521 756 387 -41 -70 -12 546 991 700 592 603 415 521 810 860 792 622 -944 -1934 -2313 -2251 -2300 -514 24 -193 -537 -837 -1222 -1532 -1306 -1050 -391 73 419 312 564 177 -176 -1153 -1899 -2548 -2887 -2657 -1659 -831 -139 94 29 -156 -50 423 542 687 378 -35 -306 -683 -1063 -1747 -1713 -1363 -1155 -497 -146 -344 -1024 -1445 -1506 -1876 -1307 -802 -1020 -1253 -420 -527 -675 -1116 -913 -599 -462 329 1484 1647 1729 928 249 -548 -1895 -3367 -3605 -3482 -2855 -1259 -457 -372 -466 -1485 -1675 -1094 -298 -178 456 1091 1160 1473 2103 2498 1778 1389 1012 493 424 1466 1416 1415 2132 1615 1488 1953 1084 329 270 -254 -1180 -244 233 802 841 1051 781 932 929 1432 1321 1300 541 -799 -1629 -1838 -312 163 1436 2070 2547 2966 3466 3207 3161 2306 1985 1450 710 359 -39 -65 -11 532 959 681 574 589 406 514 812 864 794 626 -931 -1821 -2188 -2157 -2227 -519 25 -194 -534 -830 -1206 -1506 -1297 -1059 -399 76 424 319 572 178 -176 -1183 -1888 -2507 -2823 -2626 -1695 -845 -144 99 30 -163 -52 448 579 706 403 -37 -316 -703 -1094 -1767 -1718 -1384 -1181 -513 -147 -346 -1041 -1453 -1496 -1852 -1281 -797 -1019 -1256 -415 -526 -672 -1099 -918 -598 -448 323 1477 1621 1683 875 225 -500 -1734 -3058 -3271 -3113 -2671 -1204 -460 -381 -480 -1466 -1688 -1120 -301 -182 464 1110 1181 1492 2177 2584 1863 1437 1062 506 423 1472 1447 1446 2201 1629 1533 1958 1100 333 272 -261 -1207 -244 242 835 881 1093 826 990 997 1531 1409 1377 570 -831 -1684 -1906