File name: Pandora176s1_Tsukuba-NIES_20250525_L2Fit_fwvt1c4d20240516p1-8.txt File generation date: 20250525T144523.0Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c4p1-8 Local principal investigator: Tamaki Fujinawa Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 176 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora176_OF_v3d20200605.txt Instrument calibration file used: Pandora176s1_CF_v4d20240516.txt Level 1 file used: Pandora176s1_Tsukuba-NIES_20250525_L1_smca1c4d20240516p1-8.txt Full location name: National Institute for Environmental Studies (NIES) Short location name: Tsukuba-NIES Country of location: Japan Location latitude [deg]: 36.0513 Location longitude [deg]: 140.1210 Location altitude [m]: 45 Local noon date: 20250525 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 1679 1828 Nominal wavelengths inside fitting window [nm]: 492.1082 492.2290 492.3498 492.4706 492.5914 492.7121 492.8328 492.9535 493.0742 493.1949 493.3156 493.4362 493.5569 493.6775 493.7981 493.9187 494.0392 494.1598 494.2803 494.4008 494.5213 494.6418 494.7623 494.8827 495.0032 495.1236 495.2440 495.3644 495.4847 495.6051 495.7254 495.8457 495.9660 496.0863 496.2065 496.3268 496.4470 496.5672 496.6874 496.8076 496.9278 497.0479 497.1680 497.2882 497.4082 497.5283 497.6484 497.7684 497.8885 498.0085 498.1285 498.2484 498.3684 498.4883 498.6083 498.7282 498.8481 498.9679 499.0878 499.2076 499.3275 499.4473 499.5671 499.6868 499.8066 499.9263 500.0460 500.1658 500.2854 500.4051 500.5248 500.6444 500.7640 500.8836 501.0032 501.1228 501.2423 501.3619 501.4814 501.6009 501.7204 501.8398 501.9593 502.0787 502.1981 502.3175 502.4369 502.5563 502.6756 502.7950 502.9143 503.0336 503.1529 503.2721 503.3914 503.5106 503.6298 503.7490 503.8682 503.9873 504.1065 504.2256 504.3447 504.4638 504.5829 504.7019 504.8210 504.9400 505.0590 505.1780 505.2970 505.4159 505.5349 505.6538 505.7727 505.8916 506.0104 506.1293 506.2481 506.3669 506.4857 506.6045 506.7233 506.8420 506.9608 507.0795 507.1982 507.3169 507.4355 507.5542 507.6728 507.7914 507.9100 508.0286 508.1471 508.2657 508.3842 508.5027 508.6212 508.7397 508.8581 508.9766 509.0950 509.2134 509.3318 509.4501 509.5685 509.6868 509.8051 509.9234 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Temperature at electronics board [°C], 999=no temperature signal Column 96: Spectrometer control temperature [°C], 999=no temperature signal Column 97: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 98: Temperature in head sensor [°C], 999=no temperature signal Column 99: Humidity in head sensor [%], -9=no humidity signal Column 100: Pressure in head sensor [hPa], -9=no pressure signal Columns 101-250: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 251-400: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20250525T014439.8Z 9276.072683 331 1 47.96 2 18.85 139.63 25.56 222.79 0.00 1 0.00 1 0 15 3.206e-03 3.206e-03 1.160e-03 1.156e-03 5.592776e+03 7.469168e+01 3.862486e+02 -6.000000e+00 1.779441e+02 287.26 -2.00 20.00 -2.00 505.27 0.00e+00 4.784889e-04 3.191287e-05 3.444670e-05 -6.000000e+00 9.025984e-05 287.26 -2.00 20.00 -2.00 500.39 0.00e+00 6.275520e-02 2.287446e-02 3.627935e-02 -6.000000e+00 6.329653e-02 231.76 -2.00 3.41 -2.00 501.99 0.00e+00 1.057 0.000 489.00 513.00 1 8.4080e+00 1.7514e-03 3.5286e-03 -6.0000e+00 4.8496e-03 6.4733e-03 4.5490e-04 8.8177e-04 -6.0000e+00 1.2713e-03 3.6875e-04 3.0113e-04 1.0530e-04 4.3229e-05 -6.0000e+00 3.0501e-04 -4.6622e-03 -9.7264e-06 10 0 0 10 0 0 65.40 19.80 0.79 -0.00466 -0.00257 13 3 1 4 0 3688.370 26.32 20.00 19.80 25.91 18.6 1011.16 -644 -794 -45 -218 399 182 763 178 118 110 15 -243 -135 -409 -179 -5 -135 1610 -394 172 57 372 51 273 325 416 240 -124 -116 -163 -265 -332 -283 212 340 -255 106 23 -389 -167 -46 -230 47 -22 -86 434 126 14 -59 -220 -600 -226 -654 -97 -603 233 -64 267 154 166 149 131 344 671 102 116 176 -118 -11 -464 -259 -200 -207 241 -7 103 -318 88 -238 -274 -525 -43 -345 -26 -271 -105 -255 -157 152 160 -361 164 451 -184 485 257 -81 89 -185 -464 -543 -310 -389 -125 -138 -18 -218 52 -249 89 -12 -11 -83 275 421 438 520 365 262 71 65 -121 300 23 106 78 363 47 336 375 -9 -78 -200 -348 -767 146 -227 253 -41 187 203 216 254 156 237 32 -41 -368 -351 -557 -621 -780 -45 -223 413 192 807 189 125 116 15 -250 -138 -414 -181 -5 -138 1661 -418 182 60 395 54 291 346 443 254 -130 -119 -164 -264 -334 -289 221 360 -272 111 24 -404 -172 -47 -239 50 -23 -91 457 132 15 -61 -221 -593 -219 -632 -95 -601 235 -66 274 158 170 153 135 354 688 104 118 175 -117 -11 -452 -251 -194 -203 237 -7 102 -309 84 -227 -261 -502 -41 -333 -25 -265 -103 -252 -154 148 157 -358 163 451 -185 478 249 -77 84 -170 -423 -496 -287 -370 -122 -137 -17 -215 51 -242 86 -11 -11 -83 275 422 441 526 370 264 71 64 -118 290 23 103 76 353 46 326 363 -8 -74 -188 -325 -721 138 -218 246 -40 185 201 215 254 156 236 31 -40 -355 -334 -529 SQ 20250525T020224.8Z 9276.085010 346 1 46.90 2 16.82 151.45 28.05 230.21 0.00 1 0.00 1 0 15 2.947e-03 2.936e-03 1.169e-03 1.166e-03 5.598183e+03 7.520920e+01 3.855183e+02 -6.000000e+00 1.635487e+02 287.26 -2.00 20.00 -2.00 505.27 0.00e+00 5.442045e-04 3.218611e-05 3.789064e-05 -6.000000e+00 8.295825e-05 287.26 -2.00 20.00 -2.00 500.41 0.00e+00 8.059690e-02 2.304208e-02 3.659205e-02 -6.000000e+00 5.817860e-02 231.76 -2.00 3.41 -2.00 502.00 0.00e+00 1.045 0.000 489.00 513.00 1 8.4304e+00 1.7644e-03 3.5607e-03 -6.0000e+00 4.4575e-03 4.3160e-03 4.5820e-04 8.8562e-04 -6.0000e+00 1.1686e-03 3.6036e-04 2.4813e-04 1.0633e-04 4.3564e-05 -6.0000e+00 2.8034e-04 -4.3888e-03 -1.4938e-05 10 0 0 10 0 0 64.48 19.80 0.73 -0.00439 -0.00267 12 3 1 4 0 3908.190 26.32 20.00 19.80 27.17 18.4 1018.86 -740 -496 -193 -307 302 519 514 361 399 -12 117 -244 -40 -102 -383 81 -121 847 -400 114 -35 334 68 345 211 233 318 136 -262 -207 -80 -463 -388 129 111 -186 73 69 -259 98 -93 -172 -118 -85 136 271 200 70 -63 -155 -421 -75 -558 -159 -359 271 -2 133 443 308 501 35 83 573 -121 242 17 -2 -269 -475 -274 -154 -191 498 -319 -297 -440 -59 -393 -123 -139 -417 -212 -133 -381 -77 -241 -358 366 -62 -112 297 403 26 467 282 -53 -56 -623 -209 -394 -332 -382 -105 30 14 -167 -94 -68 62 28 18 191 275 426 501 636 156 113 243 7 -149 153 -115 -105 46 488 323 45 273 -110 -82 -353 -430 -339 137 -241 268 73 406 258 160 -106 62 377 -43 76 -291 -349 -562 -714 -485 -193 -314 312 544 544 383 422 -13 122 -251 -41 -103 -386 82 -124 877 -424 120 -37 354 72 366 225 248 336 143 -270 -208 -79 -465 -397 135 118 -198 77 72 -269 100 -96 -178 -123 -90 143 286 210 72 -64 -155 -415 -73 -539 -155 -357 274 -2 137 454 315 513 36 85 588 -124 244 17 -2 -264 -464 -266 -149 -187 491 -317 -293 -428 -56 -376 -117 -133 -401 -205 -129 -374 -76 -237 -353 358 -60 -111 296 404 26 461 274 -50 -52 -576 -190 -360 -308 -364 -103 30 14 -165 -92 -66 60 28 18 191 275 428 505 643 158 114 242 7 -146 149 -113 -103 45 476 314 44 264 -107 -78 -333 -404 -318 129 -232 260 71 401 256 160 -106 62 376 -42 74 -281 -333 -535 SQ 20250525T020651.6Z 9276.088097 349 1 48.24 2 16.41 154.79 28.72 231.89 0.00 1 0.00 1 0 15 2.632e-03 2.626e-03 1.114e-03 1.111e-03 6.257087e+03 7.254897e+01 4.330573e+02 -6.000000e+00 1.460466e+02 287.26 -2.00 20.00 -2.00 505.27 0.00e+00 5.947616e-04 3.066421e-05 4.194050e-05 -6.000000e+00 7.408029e-05 287.26 -2.00 20.00 -2.00 500.39 0.00e+00 6.954244e-02 2.199119e-02 3.943033e-02 -6.000000e+00 5.195094e-02 231.76 -2.00 3.41 -2.00 501.99 0.00e+00 1.042 0.000 489.00 513.00 1 8.3668e+00 1.6838e-03 3.8085e-03 -6.0000e+00 3.9803e-03 6.3894e-03 4.3700e-04 9.6705e-04 -6.0000e+00 1.0435e-03 3.8375e-04 1.7687e-04 1.0073e-04 4.8619e-05 -6.0000e+00 2.5034e-04 -5.0397e-03 -8.6746e-06 10 0 0 10 0 0 96.91 19.80 0.76 -0.00504 -0.00381 15 4 1 4 0 3215.770 26.32 20.00 19.80 27.47 18.5 1021.47 -589 -534 115 -213 193 428 402 320 311 159 -66 1 -90 -284 -239 33 -152 831 -327 53 247 11 381 189 327 342 274 -129 -304 -253 -224 -352 -339 265 24 -120 115 -11 -384 56 -92 -84 92 69 85 99 306 -169 -62 -307 -355 -328 -283 -414 -253 283 -15 -89 217 119 238 64 54 785 92 59 171 44 -189 -267 -247 -161 -217 458 -126 -60 -235 -138 -202 -238 -203 -319 38 -232 -305 -216 -293 -406 87 263 -251 282 276 201 280 397 -274 245 -352 13 -545 -392 -584 -43 -2 -168 -47 47 38 -26 51 -111 204 163 337 409 398 243 95 219 -46 -75 57 213 34 128 381 17 36 254 -309 -282 -73 -240 -222 -111 7 3 3 144 159 245 156 259 307 104 -32 -200 -399 -384 -568 -523 115 -218 200 450 426 341 329 167 -69 1 -92 -287 -241 33 -155 862 -347 56 263 12 404 201 349 364 290 -136 -313 -255 -223 -353 -347 276 25 -128 121 -12 -399 58 -95 -87 96 72 90 105 321 -176 -63 -309 -350 -318 -273 -404 -252 287 -15 -92 223 122 244 66 56 805 95 60 171 44 -186 -261 -239 -156 -213 452 -125 -59 -228 -133 -193 -227 -193 -307 36 -225 -299 -212 -289 -400 85 257 -248 281 276 201 275 384 -261 228 -323 12 -496 -362 -555 -42 -2 -167 -46 46 37 -25 50 -110 203 163 338 411 402 247 95 218 -46 -73 55 206 33 124 370 16 35 245 -298 -268 -68 -225 -208 -105 7 3 2 142 157 244 155 258 306 103 -31 -193 -380 -365 SQ 20250525T031811.7Z 9276.137635 396 1 48.60 2 17.61 213.96 40.99 252.05 0.00 1 0.00 1 0 15 2.879e-03 2.866e-03 1.104e-03 1.101e-03 5.566662e+03 7.101853e+01 3.882047e+02 -6.000000e+00 1.597909e+02 287.26 -2.00 20.00 -2.00 505.27 0.00e+00 6.783864e-04 3.039521e-05 4.363786e-05 -6.000000e+00 8.105120e-05 287.26 -2.00 20.00 -2.00 500.41 0.00e+00 4.690680e-02 2.177211e-02 3.565493e-02 -6.000000e+00 5.683804e-02 231.76 -2.00 3.41 -2.00 502.00 0.00e+00 1.049 0.000 489.00 513.00 1 8.3478e+00 1.6670e-03 3.5419e-03 -6.0000e+00 4.3548e-03 5.2564e-03 4.3297e-04 8.7106e-04 -6.0000e+00 1.1416e-03 3.9140e-04 2.7019e-04 1.0042e-04 4.4814e-05 -6.0000e+00 2.7389e-04 -4.8561e-03 -8.6646e-06 10 0 0 10 0 0 96.06 19.80 0.78 -0.00486 -0.00298 13 3 1 4 0 3738.280 26.32 20.00 19.80 27.10 18.5 1016.94 -805 -410 -20 -44 322 506 465 244 185 123 141 -329 144 -249 -225 -122 -81 859 -80 183 360 145 228 234 184 94 185 -93 -26 -187 -214 -344 -399 265 -56 -55 51 -29 -466 166 -292 -258 122 -33 305 133 340 -189 28 -360 -545 -224 -525 -398 -389 333 70 239 72 242 195 42 4 814 8 400 -8 -128 -139 -471 12 -192 -243 217 -60 -101 -130 -309 -247 -347 -326 -347 -294 -53 -177 -169 -425 -20 51 291 -272 238 517 78 96 479 -259 131 -191 -246 -442 -528 -405 -312 -59 -422 0 -23 127 -46 94 -87 488 332 333 550 137 239 5 323 10 11 40 231 -100 -26 222 48 167 532 -168 -72 160 -496 -395 116 62 7 130 110 103 108 376 122 278 96 -15 -517 -382 -262 -777 -401 -20 -45 333 530 492 260 196 129 146 -339 146 -252 -226 -123 -83 889 -84 194 381 154 242 249 196 99 195 -98 -27 -188 -213 -345 -407 276 -60 -58 53 -31 -483 171 -301 -267 127 -35 322 140 356 -197 29 -363 -538 -217 -507 -388 -387 337 72 246 74 248 200 43 4 834 8 403 -8 -127 -137 -459 11 -186 -239 214 -59 -100 -126 -297 -236 -331 -312 -333 -284 -51 -174 -166 -419 -20 50 285 -270 237 518 78 95 465 -248 122 -176 -225 -404 -490 -386 -306 -58 -421 0 -22 123 -44 93 -87 487 333 335 554 139 243 5 322 10 10 39 224 -98 -25 217 47 163 515 -162 -69 151 -465 -371 110 60 6 127 109 102 107 375 122 277 95 -15 -499 -364 -249 SQ 20250525T032240.8Z 9276.140750 399 1 49.06 2 18.14 216.91 41.82 253.02 0.00 1 0.00 1 0 15 2.667e-03 2.662e-03 1.033e-03 1.030e-03 5.388754e+03 6.621260e+01 3.752639e+02 -6.000000e+00 1.480241e+02 287.26 -2.00 20.00 -2.00 505.27 0.00e+00 6.275378e-04 2.843356e-05 4.173674e-05 -6.000000e+00 7.508239e-05 287.26 -2.00 20.00 -2.00 500.41 0.00e+00 8.280700e-02 2.036178e-02 3.469575e-02 -6.000000e+00 5.265126e-02 231.76 -2.00 3.41 -2.00 502.00 0.00e+00 1.052 0.000 489.00 513.00 1 8.2453e+00 1.5591e-03 3.4580e-03 -6.0000e+00 4.0340e-03 5.3161e-03 4.0507e-04 8.4612e-04 -6.0000e+00 1.0575e-03 4.3279e-04 1.8350e-04 9.4102e-05 4.3238e-05 -6.0000e+00 2.5372e-04 -5.5195e-03 -2.9797e-06 10 0 0 10 0 0 87.09 19.80 0.81 -0.00552 -0.00425 16 4 1 4 0 3066.010 26.32 20.00 19.80 27.13 18.5 1017.60 -569 -310 49 -163 120 429 568 319 234 340 178 -287 -291 -162 -168 34 -228 625 -445 223 87 126 117 122 290 388 346 -179 -87 -436 -108 -380 -95 113 -5 -91 197 -12 -359 143 -338 -272 -128 233 253 415 220 119 -143 -160 -395 -459 -277 -271 -111 197 53 -152 256 87 210 -28 177 527 219 207 -22 1 -321 -289 -312 26 -442 148 -153 -85 -135 -226 -305 -400 -73 -337 -296 -124 -188 -231 -216 -75 144 234 -136 65 481 78 460 239 -129 12 -349 -90 -711 -272 -519 23 -102 -14 72 -100 -40 -158 -28 -62 289 124 321 432 542 360 132 -1 142 -149 117 1 -53 248 254 106 69 172 -306 -13 85 -250 -495 224 -110 121 46 222 379 101 413 -2 286 78 -265 -272 -263 -482 -549 -303 49 -167 124 449 600 339 247 356 184 -295 -297 -164 -169 34 -234 648 -471 237 92 134 124 130 309 412 366 -188 -90 -439 -108 -381 -97 118 -5 -96 207 -13 -372 148 -349 -282 -133 245 266 437 231 123 -147 -161 -390 -446 -267 -264 -111 199 55 -157 263 90 215 -28 182 541 223 209 -22 1 -316 -282 -303 25 -434 146 -152 -84 -131 -217 -291 -381 -70 -324 -286 -120 -184 -227 -213 -74 141 229 -134 64 481 78 454 232 -123 12 -322 -83 -652 -252 -496 23 -101 -14 71 -98 -38 -155 -28 -62 288 124 323 435 548 365 133 -1 139 -145 113 1 -52 242 248 103 67 167 -296 -12 80 -234 -466 212 -106 118 46 219 375 101 412 -2 286 77 -260 -262 -251 -459