File name: Pandora193s1_Tsukuba_20250810_L2Fit_ffus5c22d20220809p1-8.txt File generation date: 20250810T145042.9Z Data description: Level 2 spectral fitting results file Data file version: ffus5c22p1-8 Local principal investigator: Kei Shiomi Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 193 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora193_OF_v4d20210223.txt Instrument calibration file used: Pandora193s1_CF_v22d20220809.txt Level 1 file used: Pandora193s1_Tsukuba_20250810_L1_smca1c22d20220809p1-8.txt Full location name: Japan Aerospace Exploration Agency, Tsukuba Space Center (JAXA-TKSC) Short location name: Tsukuba Country of location: Japan Location latitude [deg]: 36.0661 Location longitude [deg]: 140.1244 Location altitude [m]: 51 Local noon date: 20250810 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 352 617 Nominal wavelengths inside fitting window [nm]: 322.5963 322.7359 322.8756 323.0152 323.1549 323.2945 323.4341 323.5737 323.7133 323.8529 323.9924 324.1320 324.2715 324.4111 324.5506 324.6901 324.8296 324.9691 325.1086 325.2481 325.3875 325.5270 325.6664 325.8058 325.9452 326.0846 326.2240 326.3634 326.5027 326.6421 326.7814 326.9208 327.0601 327.1994 327.3387 327.4780 327.6172 327.7565 327.8958 328.0350 328.1742 328.3134 328.4526 328.5918 328.7310 328.8702 329.0093 329.1485 329.2876 329.4268 329.5659 329.7050 329.8441 329.9831 330.1222 330.2613 330.4003 330.5393 330.6783 330.8174 330.9563 331.0953 331.2343 331.3733 331.5122 331.6512 331.7901 331.9290 332.0679 332.2068 332.3457 332.4845 332.6234 332.7622 332.9011 333.0399 333.1787 333.3175 333.4563 333.5950 333.7338 333.8726 334.0113 334.1500 334.2887 334.4274 334.5661 334.7048 334.8435 334.9821 335.1208 335.2594 335.3980 335.5366 335.6752 335.8138 335.9524 336.0909 336.2295 336.3680 336.5065 336.6450 336.7835 336.9220 337.0605 337.1990 337.3374 337.4758 337.6143 337.7527 337.8911 338.0295 338.1679 338.3062 338.4446 338.5829 338.7213 338.8596 338.9979 339.1362 339.2745 339.4127 339.5510 339.6892 339.8275 339.9657 340.1039 340.2421 340.3803 340.5185 340.6566 340.7948 340.9329 341.0710 341.2091 341.3472 341.4853 341.6234 341.7615 341.8995 342.0376 342.1756 342.3136 342.4516 342.5896 342.7276 342.8655 343.0035 343.1414 343.2794 343.4173 343.5552 343.6931 343.8310 343.9688 344.1067 344.2445 344.3824 344.5202 344.6580 344.7958 344.9336 345.0714 345.2091 345.3469 345.4846 345.6223 345.7600 345.8977 346.0354 346.1731 346.3108 346.4484 346.5861 346.7237 346.8613 346.9989 347.1365 347.2741 347.4116 347.5492 347.6867 347.8243 347.9618 348.0993 348.2368 348.3743 348.5117 348.6492 348.7866 348.9241 349.0615 349.1989 349.3363 349.4737 349.6111 349.7484 349.8858 350.0231 350.1604 350.2977 350.4350 350.5723 350.7096 350.8469 350.9841 351.1214 351.2586 351.3958 351.5330 351.6702 351.8074 351.9446 352.0817 352.2189 352.3560 352.4931 352.6302 352.7673 352.9044 353.0415 353.1785 353.3156 353.4526 353.5897 353.7267 353.8637 354.0007 354.1376 354.2746 354.4116 354.5485 354.6854 354.8224 354.9593 355.0962 355.2330 355.3699 355.5068 355.6436 355.7805 355.9173 356.0541 356.1909 356.3277 356.4645 356.6012 356.7380 356.8747 357.0114 357.1482 357.2849 357.4216 357.5582 357.6949 357.8316 357.9682 358.1049 358.2415 358.3781 358.5147 358.6513 358.7879 358.9244 359.0610 359.1975 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Temperature at electronics board [°C], 999=no temperature signal Column 165: Spectrometer control temperature [°C], 999=no temperature signal Column 166: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 167: Temperature in head sensor [°C], 999=no temperature signal Column 168: Humidity in head sensor [%], -9=no humidity signal Column 169: Pressure in head sensor [hPa], -9=no pressure signal Columns 170-435: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 436-701: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20250809T231242.4Z 9352.967157 302 1 11.95 2 51.26 99.16 122.36 274.26 0.00 1 0.00 1 0 33 1.385e-03 1.361e-03 5.138e-04 4.948e-04 6.791139e-07 1.641213e-07 3.117620e-08 4.086091e-07 4.528093e-07 231.64 -2.00 3.41 -2.00 339.80 0.00e+00 -6.839322e-05 4.493947e-05 8.112580e-06 2.161066e-05 1.244137e-04 292.37 -2.00 20.00 -2.00 337.20 0.00e+00 1.036744e-04 6.871163e-06 8.649477e-07 2.660510e-05 2.102161e-05 292.37 -2.00 20.00 -2.00 346.00 0.00e+00 2.283419e-04 2.024772e-05 1.403984e-05 1.079359e-05 6.083177e-05 292.37 -2.00 20.00 -2.00 344.56 0.00e+00 -3.179918e+05 4.116444e+04 2.259413e+04 2.133173e+05 1.149047e+05 273.27 -2.00 10.95 -2.00 351.93 0.00e+00 1.968864e-01 5.930793e-04 1.529610e-03 1.512323e-03 1.459353e-03 231.64 -2.00 3.41 -2.00 330.13 0.00e+00 -5.228094e-04 6.505936e-04 1.534989e-04 8.445326e-05 1.415745e-03 292.37 -2.00 20.00 -2.00 328.18 0.00e+00 1.594 0.000 319.50 362.20 4 2.6430e+00 6.8805e-04 1.1227e-02 1.5229e-03 2.0410e-03 -2.9478e-03 1.6444e-04 1.7616e-03 3.0299e-04 4.6067e-04 -2.0546e-03 3.1873e-04 3.2685e-04 1.2751e-04 8.8977e-04 -2.0889e-03 1.4367e-04 2.7413e-04 9.6291e-05 3.4988e-04 3.1088e-03 2.4445e-04 1.9226e-04 8.3160e-05 6.4820e-04 2.2317e-02 -9.1031e-03 4.1397e-04 1.2764e-04 8.2845e-05 1.1852e-03 3.3489e-04 7.1347e-06 2.0627e-06 8.3149e-07 2.0720e-05 3.4119e-02 -7.4089e-05 -1.6763e-01 4.1572e-02 9.5209e-03 4.9165e-03 1.1797e-01 12 9 9 12 1 1 99.79 22.29 0.53 0.03412 0.03825 34 29 1 5 0 341.210 24.75 20.01 22.29 34.75 15.3 1019.88 -181 503 81 105 173 79 232 98 -54 81 -223 199 -17 -148 -2 -158 -79 -192 70 -179 -147 -11 -185 -160 92 -101 69 150 -48 179 -206 -51 -42 -69 -57 -17 -56 -67 -71 33 254 -91 285 8 93 -7 31 -32 0 -82 -117 165 -227 124 64 -227 194 70 -116 241 -67 -106 57 -45 111 25 83 -33 -54 195 84 56 -120 4 251 9 47 -78 -2 -60 20 -70 -78 -73 -17 -40 -317 -62 -75 -251 87 -189 158 121 -75 -65 54 281 55 164 -25 132 203 109 -14 83 159 104 -103 4 -39 -158 89 -102 -167 208 15 -145 79 -104 81 55 -67 86 54 -39 -6 42 73 -120 92 112 80 -232 20 -286 -122 -73 -93 -267 17 -5 -223 -105 159 13 150 -14 202 112 199 318 -50 187 139 8 151 -130 59 25 33 -197 138 -72 115 131 -28 -64 -101 38 -211 -7 -131 -92 201 60 88 98 -230 -51 -177 -77 -44 -173 -52 8 72 4 -26 56 -101 255 -41 -260 71 -145 -168 -39 108 65 41 93 44 -30 -46 -129 -173 -226 -111 -55 95 91 119 71 -133 -58 -200 5 -13 -85 -10 140 -133 33 9 29 -61 -101 -98 203 54 259 303 124 134 -142 -4 -36 -155 51 -73 283 214 -40 326 58 -257 79 -252 -240 22 -124 47 213 -58 -168 245 -38 148 38 -310 -63 -4 -88 -118 900000 -110 304 48 67 112 53 158 66 -37 58 -165 150 -13 -110 -2 -116 -56 -136 52 -137 -116 -9 -156 -140 79 -88 61 131 -43 156 -183 -44 -37 -60 -50 -15 -48 -58 -61 28 220 -80 244 7 80 -6 28 -31 0 -81 -118 162 -226 124 63 -217 176 64 -103 219 -63 -100 53 -41 104 24 81 -32 -50 184 78 53 -115 4 238 8 45 -73 -2 -56 19 -65 -73 -71 -17 -40 -320 -60 -73 -248 86 -192 166 124 -73 -61 46 242 49 157 -24 128 186 96 -13 74 151 102 -106 4 -38 -150 85 -102 -170 214 15 -151 81 -103 81 55 -69 93 59 -43 -7 45 78 -126 95 115 84 -240 20 -287 -122 -74 -100 -292 18 -6 -237 -109 168 14 168 -15 222 121 214 337 -53 181 127 7 135 -120 57 26 35 -211 149 -79 126 142 -30 -66 -102 39 -220 -7 -139 -101 224 67 98 108 -241 -51 -179 -78 -46 -188 -57 8 77 5 -28 60 -107 262 -42 -269 73 -151 -180 -43 126 79 49 109 51 -35 -52 -146 -190 -239 -120 -61 110 105 138 78 -142 -59 -203 5 -14 -96 -11 161 -156 38 11 34 -71 -118 -116 240 65 306 360 148 158 -167 -4 -40 -175 57 -83 328 248 -46 366 63 -261 77 -247 -235 22 -130 50 230 -62 -167 229 -35 131 33 -284 -58 -3 -91 -127 900000 SS 20250809T231740.4Z 9352.970607 305 1 7.47 2 50.27 100.03 123.30 275.03 0.00 1 0.00 1 0 33 1.426e-03 1.358e-03 7.896e-04 7.613e-04 2.934560e-07 2.525513e-07 3.092898e-08 4.086131e-07 4.662889e-07 231.64 -2.00 3.41 -2.00 339.74 0.00e+00 8.006909e-05 6.892819e-05 8.293980e-06 2.160404e-05 1.277704e-04 292.37 -2.00 20.00 -2.00 337.14 0.00e+00 4.041502e-05 1.060220e-05 7.165115e-07 2.660497e-05 2.170206e-05 292.37 -2.00 20.00 -2.00 345.97 0.00e+00 2.239040e-04 3.117618e-05 1.518036e-05 1.079915e-05 6.264297e-05 292.37 -2.00 20.00 -2.00 344.51 0.00e+00 -1.329810e+05 6.322797e+04 2.192286e+04 2.133034e+05 1.180767e+05 273.27 -2.00 10.95 -2.00 351.91 0.00e+00 1.930553e-01 9.098128e-04 1.499369e-03 1.512382e-03 1.500457e-03 231.64 -2.00 3.41 -2.00 330.10 0.00e+00 -1.264863e-03 9.992228e-04 1.490451e-04 8.408459e-05 1.457876e-03 292.37 -2.00 20.00 -2.00 328.14 0.00e+00 1.561 0.000 319.50 362.20 4 3.0178e+00 1.0575e-03 1.0996e-02 1.5229e-03 2.0982e-03 3.3173e-03 2.5147e-04 1.7258e-03 3.0313e-04 4.7243e-04 -1.3483e-03 4.8866e-04 3.2110e-04 1.2667e-04 9.1385e-04 -1.7635e-03 2.2033e-04 2.6830e-04 9.6208e-05 3.5965e-04 2.2933e-03 3.7439e-04 1.9009e-04 8.2893e-05 6.6446e-04 1.5654e-02 -6.5402e-03 6.4016e-04 1.2317e-04 8.1712e-05 1.2225e-03 3.3452e-04 1.1002e-05 2.0279e-06 8.3728e-07 2.1341e-05 3.4209e-02 -5.9212e-05 -1.5088e-01 6.4066e-02 9.0311e-03 4.8034e-03 1.2188e-01 12 9 9 12 1 1 99.47 22.30 0.52 0.03421 0.03834 16 23 1 5 0 438.750 24.75 20.02 22.30 35.18 15.3 1021.89 -207 612 94 172 13 38 233 114 149 139 -351 98 84 46 -234 -222 68 -150 -96 -323 -252 86 -114 -313 234 -123 -71 85 18 155 -145 -67 -207 -100 71 -20 34 48 -222 18 278 -79 222 -8 65 -32 121 -142 162 -54 -21 75 -236 56 60 -87 201 -3 22 327 -45 -59 187 -8 123 155 55 -121 -64 138 -22 -4 -66 18 235 70 41 -209 103 57 -18 -226 -126 10 99 103 -246 -22 -209 -344 180 -261 137 48 -68 -95 39 134 8 -82 -11 104 58 -20 23 116 153 -43 -40 84 -4 -68 105 -134 -50 182 118 -59 190 -89 77 -52 -44 48 -183 -63 16 59 60 -107 15 18 57 -120 43 -211 -9 -18 48 22 -83 -71 -200 -4 84 29 -45 55 207 -53 187 255 -129 260 -68 -37 48 -98 167 -47 -61 -76 107 -63 66 131 -180 71 -238 55 -325 109 -111 -8 245 1 136 129 -61 -69 -211 -123 162 -156 -25 77 -8 -17 -70 148 -189 254 -25 -196 122 10 -179 -18 34 -17 53 70 37 120 35 -144 -82 -151 -249 19 25 53 147 -34 -166 -22 -112 107 19 -63 88 84 -51 66 25 -18 25 -226 -76 140 -131 82 114 120 47 40 66 111 -91 30 -277 156 176 -50 87 199 -237 -46 -259 -307 310 -27 59 291 -68 -5 251 -197 -12 -43 -247 52 78 -96 -96 900000 -125 370 59 109 9 25 158 79 103 102 -258 73 64 35 -174 -161 50 -110 -70 -244 -206 72 -98 -271 205 -109 -61 76 15 137 -130 -59 -180 -89 63 -18 29 41 -187 15 236 -67 194 -7 57 -29 114 -137 160 -54 -21 74 -237 57 59 -84 185 -3 20 300 -42 -54 175 -7 117 147 54 -118 -61 132 -21 -3 -64 17 224 67 39 -196 95 51 -16 -212 -119 10 97 104 -249 -21 -205 -340 177 -266 144 49 -67 -86 34 113 7 -79 -11 101 53 -18 20 104 146 -42 -41 83 -4 -65 101 -134 -51 187 123 -61 193 -88 77 -52 -45 52 -202 -70 17 65 63 -112 15 19 60 -124 44 -211 -9 -18 51 24 -92 -77 -211 -5 89 31 -50 61 225 -58 201 268 -136 259 -62 -32 43 -91 160 -48 -63 -83 118 -69 72 144 -195 75 -244 56 -336 113 -120 -8 270 1 154 140 -63 -71 -212 -124 169 -168 -27 83 -9 -18 -75 160 -197 258 -25 -206 124 11 -195 -21 39 -20 64 83 43 139 40 -159 -89 -162 -267 21 29 62 167 -38 -173 -23 -112 110 20 -72 101 98 -59 76 30 -21 29 -266 -90 165 -157 97 135 143 55 47 77 126 -102 34 -318 180 203 -57 95 214 -242 -45 -249 -302 312 -27 63 314 -70 -5 237 -179 -11 -38 -221 47 76 -98 -103 900000 SS 20250810T032509.2Z 9353.142467 463 1 49.56 2 22.44 206.16 158.15 358.61 0.00 1 0.00 1 0 33 2.785e-03 2.652e-03 1.075e-03 1.047e-03 5.533646e-07 3.417175e-07 2.276417e-08 4.087530e-07 9.097649e-07 231.63 -2.00 3.41 -2.00 339.10 0.00e+00 3.642032e-05 9.162701e-05 5.186924e-06 2.156058e-05 2.436699e-04 292.38 -2.00 20.00 -2.00 336.48 0.00e+00 -1.105684e-05 1.504697e-05 2.748290e-07 2.660410e-05 4.329851e-05 292.38 -2.00 20.00 -2.00 345.38 0.00e+00 8.135811e-05 4.355296e-05 9.302403e-06 1.091382e-05 1.221674e-04 292.38 -2.00 20.00 -2.00 343.82 0.00e+00 -2.256719e+05 8.553003e+04 1.540066e+04 2.131495e+05 2.269505e+05 273.27 -2.00 10.95 -2.00 351.49 0.00e+00 1.304221e-01 1.170929e-03 1.057103e-03 1.511994e-03 2.869399e-03 231.63 -2.00 3.41 -2.00 329.83 0.00e+00 2.732362e-03 1.305402e-03 8.635561e-05 8.277815e-05 2.853894e-03 292.38 -2.00 20.00 -2.00 327.88 0.00e+00 1.082 0.000 319.50 362.20 4 5.8484e+00 1.4546e-03 7.6151e-03 1.5233e-03 4.0520e-03 4.3756e-02 3.3162e-04 1.1959e-03 3.0373e-04 8.9617e-04 -3.9937e-03 6.5149e-04 2.1520e-04 1.2153e-04 1.7410e-03 -1.5663e-03 2.9112e-04 1.8403e-04 9.6951e-05 6.9256e-04 2.4831e-03 4.9206e-04 1.3114e-04 8.2219e-05 1.2468e-03 1.3036e-03 -1.1108e-02 8.9856e-04 7.8365e-05 7.8147e-05 2.4501e-03 2.8559e-04 1.5430e-05 1.5168e-06 8.9941e-07 4.1660e-05 3.3288e-02 -1.4433e-04 3.0501e-01 9.0482e-02 4.9569e-03 4.4754e-03 2.4411e-01 12 9 8 11 32 0 99.96 22.26 1.26 0.03329 0.03681 19 4 1 5 0 2607.680 24.65 20.00 22.26 33.08 15.4 1012.67 118 590 -58 101 446 379 804 -309 362 318 -106 -292 136 -441 -577 -122 -710 -264 -529 -188 -33 143 -30 -194 109 95 374 -232 -317 -179 149 -122 -126 -336 581 141 -474 232 -131 119 337 -588 311 483 289 -194 -48 -6 220 -41 -241 290 -346 -116 -26 30 520 71 -52 580 -99 71 106 -83 129 74 -86 249 -457 105 -64 40 -299 414 118 -192 222 -241 12 -513 216 -275 9 -8 120 235 -127 -284 -140 118 330 -44 183 132 -587 193 -139 -419 317 -574 219 -40 94 -145 -77 208 582 -83 152 248 44 -434 -113 -157 -386 403 328 48 354 -311 -131 -40 -211 -241 34 90 33 172 202 63 -31 191 53 -148 -25 -538 374 194 46 -59 -11 -211 -345 -156 47 -241 553 28 269 -119 280 583 -141 -179 84 128 237 6 -79 -82 -53 -78 77 116 -10 408 -314 -236 -915 135 -438 -20 -320 -137 341 -9 -25 406 -367 -28 -471 -393 243 -14 129 230 -124 125 -53 20 -480 242 293 172 53 10 156 -133 3 -95 -118 247 41 57 48 -54 -104 -131 246 89 -144 318 -101 151 241 -229 -22 125 -429 -402 118 271 -190 93 -79 -57 8 -326 61 239 -38 -188 322 -47 -5 -143 237 364 -191 52 51 175 -57 -15 21 207 -398 302 115 -397 365 -243 -353 533 -111 -203 643 -88 800 -557 -282 27 -12 -300 -156 900000 77 376 -38 67 307 267 569 -222 266 242 -83 -232 109 -355 -459 -96 -550 -203 -419 -154 -28 127 -28 -182 103 90 350 -216 -297 -170 142 -115 -118 -313 540 132 -441 212 -119 107 307 -537 280 434 265 -185 -47 -6 228 -43 -253 305 -368 -122 -27 30 498 67 -49 556 -97 69 103 -81 126 73 -87 250 -451 102 -62 40 -299 411 117 -190 220 -236 11 -484 203 -265 8 -8 123 243 -131 -288 -140 118 336 -46 196 140 -594 180 -120 -360 287 -556 216 -38 86 -129 -68 189 556 -84 157 251 44 -421 -110 -159 -403 422 347 50 361 -312 -130 -40 -221 -263 38 101 37 190 217 66 -33 198 56 -154 -26 -541 373 198 49 -65 -12 -228 -368 -164 50 -264 611 31 296 -129 299 616 -147 -175 76 110 203 5 -75 -82 -55 -84 83 126 -10 438 -334 -243 -912 134 -444 -21 -339 -147 370 -10 -28 435 -377 -27 -458 -391 250 -15 137 241 -130 132 -56 21 -489 238 289 172 54 10 164 -145 3 -111 -137 284 46 64 53 -59 -110 -135 257 95 -160 358 -112 161 243 -222 -21 124 -448 -437 130 301 -213 105 -90 -66 9 -373 70 274 -44 -218 373 -55 -6 -163 262 396 -207 56 55 191 -63 -16 22 210 -384 276 105 -367 341 -237 -357 539 -110 -191 560 -74 645 -450 -232 23 -11 -289 -159 900000 SS 20250810T043822.6Z 9353.193317 507 1 19.91 2 32.58 238.24 153.17 38.77 0.00 1 0.00 1 0 33 1.342e-03 1.306e-03 6.647e-04 6.482e-04 7.625041e-08 2.121260e-07 2.338382e-08 4.087154e-07 4.385553e-07 231.63 -2.00 3.41 -2.00 339.26 0.00e+00 4.615828e-05 5.727600e-05 5.718931e-06 2.156966e-05 1.185277e-04 292.38 -2.00 20.00 -2.00 336.64 0.00e+00 3.386717e-05 9.213394e-06 4.834399e-07 2.660432e-05 2.069335e-05 292.38 -2.00 20.00 -2.00 345.55 0.00e+00 1.240067e-04 2.680499e-05 9.466765e-06 1.088353e-05 5.889371e-05 292.38 -2.00 20.00 -2.00 344.02 0.00e+00 -2.788827e+05 5.306178e+04 1.721209e+04 2.132024e+05 1.099218e+05 273.27 -2.00 10.95 -2.00 351.70 0.00e+00 1.451509e-01 7.343618e-04 1.143563e-03 1.512351e-03 1.389860e-03 231.63 -2.00 3.41 -2.00 329.84 0.00e+00 2.243203e-04 8.065941e-04 1.092257e-04 8.398661e-05 1.372443e-03 292.38 -2.00 20.00 -2.00 327.87 0.00e+00 1.186 0.000 319.50 362.20 4 3.9537e+00 9.0216e-04 8.3501e-03 1.5232e-03 1.9658e-03 1.9043e-02 2.0754e-04 1.3108e-03 3.0342e-04 4.3566e-04 -3.4122e-03 4.0723e-04 2.3410e-04 1.2235e-04 8.4762e-04 -1.3542e-03 1.8030e-04 2.0462e-04 9.7254e-05 3.3489e-04 2.5550e-03 3.0737e-04 1.4704e-04 8.2871e-05 6.0948e-04 8.0304e-03 -7.7011e-03 5.5411e-04 8.8220e-05 8.0193e-05 1.1755e-03 3.1413e-04 9.4314e-06 1.6432e-06 8.7633e-07 2.0077e-05 3.3363e-02 -7.5839e-05 -1.7488e-01 5.5759e-02 6.1337e-03 4.6726e-03 1.1746e-01 12 9 9 12 1 1 99.74 22.30 0.55 0.03336 0.03724 21 11 1 5 0 904.650 24.65 20.00 22.30 32.88 15.6 1012.39 -182 303 295 -39 281 14 273 35 124 65 -199 9 -171 -94 -68 -179 69 -231 -66 -47 -191 181 -227 12 163 79 115 46 -135 32 -128 -4 -236 -168 84 -170 -24 -75 -60 65 185 -179 144 118 73 -7 -7 -42 112 30 -214 182 -188 73 225 -222 193 -51 16 205 36 -27 85 13 68 43 -32 54 -56 115 -183 98 -72 121 86 184 21 -166 15 -140 -52 -236 67 -10 114 -10 -133 -69 -55 -216 33 -155 221 171 -64 -22 -47 157 -103 5 68 73 78 -68 62 -63 205 -18 5 -45 69 -125 118 -113 -142 231 -1 -120 169 -117 -120 -8 -153 -84 13 158 61 -59 67 54 89 65 -61 -149 125 -219 55 17 -59 -54 21 50 -93 -94 141 -108 98 -79 -40 12 25 300 -60 201 83 -62 244 -101 49 0 126 -243 215 11 78 182 -54 -35 -253 118 -287 101 -99 -34 211 -20 65 38 -256 11 -289 -101 42 -198 -56 -148 72 38 40 133 -127 174 -31 -150 85 -102 -60 38 22 42 -115 126 28 2 69 -116 -117 -266 95 46 68 50 -17 113 -172 101 -150 59 61 -53 45 156 -26 58 -52 -128 -73 -36 -59 61 -10 67 273 40 84 -200 122 90 -190 64 39 242 72 -150 36 128 -173 99 -200 -307 94 -140 37 267 38 -90 387 -150 214 48 -151 -31 87 -228 -185 900000 -121 197 193 -27 196 10 196 26 92 49 -155 7 -137 -76 -53 -140 53 -178 -52 -38 -162 158 -205 11 151 73 105 42 -125 30 -120 -3 -217 -154 77 -156 -22 -68 -54 58 166 -161 128 105 66 -6 -7 -42 113 30 -220 187 -195 75 228 -220 183 -47 15 194 35 -26 82 13 66 42 -32 54 -54 110 -177 96 -71 119 84 180 21 -161 14 -132 -49 -226 65 -10 115 -10 -136 -69 -54 -214 33 -161 234 178 -64 -20 -41 135 -93 5 67 70 72 -61 55 -57 197 -18 5 -45 68 -121 115 -113 -146 241 -1 -125 173 -118 -119 -8 -159 -91 14 176 68 -64 71 57 92 67 -63 -155 127 -220 55 17 -63 -59 22 54 -99 -99 149 -118 108 -87 -44 13 26 317 -62 196 76 -55 214 -92 47 0 131 -260 232 12 84 195 -57 -36 -253 118 -293 105 -105 -36 228 -22 71 41 -264 11 -285 -101 43 -211 -60 -156 76 41 42 139 -131 174 -31 -152 86 -105 -63 42 25 49 -133 145 32 3 76 -127 -125 -277 100 50 76 57 -19 121 -177 99 -148 60 64 -58 50 175 -29 66 -60 -147 -84 -41 -68 70 -12 77 318 47 98 -228 136 99 -208 70 43 268 80 -167 39 132 -171 93 -189 -293 90 -140 38 276 38 -87 350 -131 182 41 -130 -27 80 -226 -192 900000 SS 20250810T044337.3Z 9353.196960 510 1 50.22 2 33.49 239.85 152.50 40.99 0.00 1 0.00 1 0 49 1.337e-03 1.289e-03 5.041e-04 4.909e-04 1.010057e-07 1.606183e-07 2.693278e-08 4.087224e-07 4.368994e-07 231.63 -2.00 3.41 -2.00 339.25 0.00e+00 1.271786e-04 4.326605e-05 6.097936e-06 2.156591e-05 1.177637e-04 292.38 -2.00 20.00 -2.00 336.63 0.00e+00 -2.356586e-05 6.999472e-06 5.220845e-07 2.660427e-05 2.067226e-05 292.38 -2.00 20.00 -2.00 345.53 0.00e+00 1.338947e-04 2.033141e-05 9.657067e-06 1.088894e-05 5.866993e-05 292.38 -2.00 20.00 -2.00 343.99 0.00e+00 -1.067650e+05 4.019795e+04 1.712480e+04 2.131892e+05 1.093402e+05 273.27 -2.00 10.95 -2.00 351.63 0.00e+00 1.445063e-01 5.562458e-04 1.140658e-03 1.512120e-03 1.383993e-03 231.63 -2.00 3.41 -2.00 329.86 0.00e+00 -4.793152e-05 6.136784e-04 1.050360e-04 8.358938e-05 1.368293e-03 292.38 -2.00 20.00 -2.00 327.90 0.00e+00 1.198 0.000 319.50 362.20 4 4.3329e+00 6.8243e-04 8.4367e-03 1.5232e-03 1.9499e-03 3.1013e-02 1.5674e-04 1.3237e-03 3.0352e-04 4.3268e-04 -1.7325e-03 3.0741e-04 2.3531e-04 1.2215e-04 8.4116e-04 -1.2576e-03 1.3685e-04 2.0327e-04 9.7095e-05 3.3345e-04 1.5659e-03 2.3250e-04 1.4633e-04 8.2607e-05 6.0459e-04 5.4188e-03 -3.9881e-03 4.2237e-04 8.6220e-05 7.8614e-05 1.1664e-03 2.8743e-04 7.1661e-06 1.6342e-06 8.8107e-07 2.0003e-05 3.3529e-02 -8.9366e-05 -1.2732e-01 4.2266e-02 5.9687e-03 4.5925e-03 1.1697e-01 12 9 8 11 8 0 99.98 22.30 0.54 0.03353 0.03708 66 13 1 5 0 760.840 24.75 20.00 22.30 33.15 15.5 1013.72 -238 395 338 71 58 52 144 180 112 143 -207 24 59 -282 -129 -191 23 -183 -193 -32 -152 104 -118 -78 72 62 16 197 -193 147 -220 1 -182 -152 60 -66 -27 17 -68 66 211 -221 193 82 111 13 32 -29 151 -84 -195 148 -197 78 86 -40 153 50 -6 208 9 -157 163 -84 42 82 55 34 -111 104 -104 105 -223 173 125 46 29 -146 15 -153 -4 -67 -25 111 132 98 -121 -91 -2 -170 170 -118 120 17 -139 -47 -139 -2 -20 -49 -20 92 63 -151 -78 32 269 11 -31 115 151 -258 11 -102 -203 282 59 -110 170 -111 -38 88 -147 9 -43 -52 20 44 80 -32 -105 89 80 -133 98 -182 23 45 42 -21 67 75 -158 -59 118 -65 63 -74 37 -7 86 298 -24 208 -62 -82 39 -115 93 -13 28 -116 152 -82 61 195 -87 32 -259 29 -264 54 -183 -123 191 19 32 263 -246 5 -168 -220 8 -17 12 -2 94 26 -24 151 -186 351 33 -161 115 -83 41 -75 62 -141 -74 57 -56 79 7 -147 -98 -106 -73 -31 -41 115 -10 67 23 12 46 36 148 -37 54 116 -155 65 -26 -70 -53 0 -39 165 -101 -39 163 -20 21 -116 116 -51 -124 99 -68 221 168 -110 125 161 -234 54 -173 -158 136 -230 -89 374 85 -101 406 -73 250 -118 -166 -77 33 -161 -166 900000 -156 252 218 47 40 37 102 129 82 108 -161 19 47 -225 -101 -149 17 -140 -151 -26 -129 91 -107 -73 67 58 14 181 -179 137 -207 1 -168 -140 55 -61 -25 15 -61 59 189 -200 172 73 101 12 32 -29 154 -86 -201 153 -206 81 87 -40 146 47 -5 198 8 -152 157 -81 41 81 55 34 -108 100 -101 102 -221 170 122 45 29 -142 14 -143 -4 -64 -24 110 134 101 -124 -92 -2 -169 171 -124 128 18 -139 -44 -121 -2 -18 -47 -19 89 58 -134 -68 29 257 12 -32 116 149 -250 11 -103 -210 294 62 -116 173 -112 -38 88 -153 9 -48 -58 22 48 86 -34 -109 92 83 -138 100 -183 23 46 45 -23 73 81 -168 -62 126 -71 70 -82 41 -8 92 316 -25 203 -57 -72 34 -104 89 -13 30 -125 164 -89 66 210 -93 34 -259 29 -269 57 -194 -133 207 21 35 282 -254 5 -165 -220 8 -18 12 -2 98 28 -26 158 -190 349 33 -162 116 -86 43 -82 70 -166 -86 66 -64 88 8 -161 -104 -110 -77 -34 -45 130 -11 72 23 11 45 36 156 -41 60 130 -174 73 -30 -81 -61 0 -46 191 -117 -45 190 -23 24 -132 129 -56 -135 108 -75 244 187 -123 134 165 -230 50 -161 -149 130 -228 -91 385 86 -97 363 -62 209 -98 -140 -67 30 -159 -172 900000