File name: Pandora248s1_TurlockCA_20230713_L2Fit_ffuh5c2d20221229p1-8.txt
File generation date: 20240224T081750.9Z
Data description: Level 2 spectral fitting results file
Data file version: ffuh5c2p1-8
Local principal investigator: Wing To
Network principal investigator: Alexander Cede
Instrument type: Pandora
Instrument number: 248
Spectrometer number: 1
Processing software version used: BlickP v1.8.59
Instrument operation file used: Pandora248_OF_v2d20221012.txt
Instrument calibration file used: Pandora248s1_CF_v2d20221229.txt
Level 1 file used: Pandora248s1_TurlockCA_20230713_L1_smca1c2d20221229p1-8.txt
Full location name: California State University, Stanislaus
Short location name: TurlockCA
Country of location: United States
Location latitude [deg]: 37.5230
Location longitude [deg]: -120.8550
Location altitude [m]: 45
Local noon date: 20230713
Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method)
Data caveats: OoB session based on session 1
First and last pixel inside fitting window: 364 584
Nominal wavelengths inside fitting window [nm]: 328.5994 328.7384 328.8774 329.0164 329.1554 329.2944 329.4334 329.5723 329.7113 329.8502 329.9891 330.1280 330.2669 330.4058 330.5446 330.6835 330.8223 330.9612 331.1000 331.2388 331.3776 331.5164 331.6551 331.7939 331.9327 332.0714 332.2101 332.3488 332.4875 332.6262 332.7649 332.9035 333.0422 333.1808 333.3194 333.4581 333.5967 333.7352 333.8738 334.0124 334.1509 334.2895 334.4280 334.5665 334.7050 334.8435 334.9820 335.1204 335.2589 335.3973 335.5358 335.6742 335.8126 335.9510 336.0894 336.2277 336.3661 336.5044 336.6428 336.7811 336.9194 337.0577 337.1960 337.3342 337.4725 337.6107 337.7490 337.8872 338.0254 338.1636 338.3018 338.4399 338.5781 338.7162 338.8544 338.9925 339.1306 339.2687 339.4068 339.5449 339.6829 339.8210 339.9590 340.0970 340.2350 340.3730 340.5110 340.6490 340.7869 340.9249 341.0628 341.2007 341.3387 341.4766 341.6144 341.7523 341.8902 342.0280 342.1659 342.3037 342.4415 342.5793 342.7171 342.8549 342.9926 343.1304 343.2681 343.4058 343.5435 343.6812 343.8189 343.9566 344.0942 344.2319 344.3695 344.5072 344.6448 344.7824 344.9200 345.0575 345.1951 345.3326 345.4702 345.6077 345.7452 345.8827 346.0202 346.1577 346.2951 346.4326 346.5700 346.7074 346.8448 346.9822 347.1196 347.2570 347.3944 347.5317 347.6690 347.8064 347.9437 348.0810 348.2182 348.3555 348.4928 348.6300 348.7673 348.9045 349.0417 349.1789 349.3161 349.4532 349.5904 349.7275 349.8647 350.0018 350.1389 350.2760 350.4131 350.5501 350.6872 350.8242 350.9613 351.0983 351.2353 351.3723 351.5093 351.6462 351.7832 351.9201 352.0570 352.1940 352.3309 352.4678 352.6046 352.7415 352.8784 353.0152 353.1520 353.2888 353.4256 353.5624 353.6992 353.8360 353.9727 354.1094 354.2462 354.3829 354.5196 354.6563 354.7929 354.9296 355.0662 355.2029 355.3395 355.4761 355.6127 355.7493 355.8858 356.0224 356.1589 356.2955 356.4320 356.5685 356.7050 356.8415 356.9779 357.1144 357.2508 357.3873 357.5237 357.6601 357.7965 357.9328 358.0692 358.2055 358.3419 358.4782 358.6145 358.7508 358.8871
---------------------------------------------------------------------------------------
Column 1: Two letter code of measurement routine
Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601)
Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement
Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.)
Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.)
Column 6: Total duration of measurement set in seconds
Column 7: Data processing type index
Column 8: Solar zenith angle for center-time of measurement in degree
Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 10: Lunar zenith angle for center-time of measurement in degree
Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used
Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon
Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used
Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4)
Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error
Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done
Column 18: rms of unweighted fitting residuals, -9=fitting not successful
Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used
Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 22: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful
Column 23: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 24: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 25: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 26: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 27: Formaldehyde effective temperature [K]
Column 28: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 29: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 30: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 31: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful
Column 32: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 38: Nitrogen dioxide effective temperature [K]
Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful
Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 44: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful
Column 45: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 46: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 47: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 48: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 49: Oxygen dimer effective temperature [K]
Column 50: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 51: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 52: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 53: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful
Column 54: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 55: Ozone slant column amount [moles per square meter], -9e99=fitting not successful
Column 56: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 57: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 58: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 59: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 60: Ozone effective temperature [K]
Column 61: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 62: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 63: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 64: Effective ozone fitting wavelength [nm], -9=fitting not successful
Column 65: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 66: Fitted Ring spectrum, -9e99=no fitting done or fitting not successful
Column 67: Independent uncertainty of fitted Ring spectrum, -9=fitting not successful
Column 68: Structured uncertainty of fitted Ring spectrum, -9=fitting not successful
Column 69: Common uncertainty of fitted Ring spectrum, -9=fitting not successful
Column 70: rms-based uncertainty of fitted Ring spectrum, -9=fitting not successful
Column 71: Effective Ring fitting wavelength [nm], -9=fitting not done or not successful
Column 72: Diffuse correction applied before fitting at effective Ring fitting wavelength [%], 0=no diffuse correction applied, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 73: Lower limit used for wavelength scaling [nm]
Column 74: Upper limit used for wavelength scaling [nm]
Column 75: Order of smoothing polynomial
Column 76: Smoothing polynomial coefficient, order 0
Column 77: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 78: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 79: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 80: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 81: Smoothing polynomial coefficient, order 1
Column 82: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 83: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 84: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 85: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 86: Smoothing polynomial coefficient, order 2
Column 87: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 88: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 89: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 90: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 91: Smoothing polynomial coefficient, order 3
Column 92: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 93: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 94: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 95: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 96: Smoothing polynomial coefficient, order 4
Column 97: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 98: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 99: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 100: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 101: Mean value of measured data inside fitting window [same units as measurements]
Column 102: Offset polynomial coefficient, order 0
Column 103: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 104: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 105: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 106: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 107: Offset polynomial coefficient, order 1
Column 108: Independent uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful
Column 109: Structured uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful
Column 110: Common uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful
Column 111: rms-based uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful
Column 112: Wavelength change polynomial coefficient, order 0
Column 113: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 114: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 115: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 116: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 117: Wavelength change polynomial coefficient, order 1
Column 118: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 119: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 120: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 121: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 122: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination
Column 123: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination
Column 124: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 125: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large
Column 126: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 127: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 128: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature
Column 129: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 130: Atmospheric variability [%], 999=no atmospheric variability was determined
Column 131: Wavelength effective temperature [�C], 999=no effective temperature given
Column 132: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher)
Column 133: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination
Column 134: Retrieved total wavelength shift [nm], -9=no wavelength change fitting
Column 135: Number of bright count cycles
Column 136: Number of dark count cycles
Column 137: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions
Column 138: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions
Column 139: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal
Column 140: Integration time [ms]
Column 141: Temperature at electronics board [�C], 999=no temperature signal
Column 142: Spectrometer control temperature [�C], 999=no temperature signal
Column 143: Auxiliary spectrometer temperature [�C], 999=no temperature signal
Column 144: Temperature in head sensor [�C], 999=no temperature signal
Column 145: Humidity in head sensor [%], -9=no humidity signal
Column 146: Pressure in head sensor [hPa], -9=no pressure signal
Columns 147-367: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting
Columns 368-588: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given
---------------------------------------------------------------------------------------