File name: Pandora150s1_Ulsan_20211008_L2Fit_fnvs5c10d20210715p1-8.txt File generation date: 20240805T234201.6Z Data description: Level 2 spectral fitting results file Data file version: fnvs5c10p1-8 Local principal investigator: Chang Keun Song Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 150 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora150_OF_v3d20210223.txt Instrument calibration file used: Pandora150s1_CF_v10d20210715.txt Level 1 file used: Pandora150s1_Ulsan_20211008_L1_smca1c10d20210715p1-8.txt Full location name: Ulsan National Institute of Science and Technology, UNIST Short location name: Ulsan Country of location: South Korea Location latitude [deg]: 35.5745 Location longitude [deg]: 129.1896 Location altitude [m]: 38 Local noon date: 20211008 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 927 1472 Nominal wavelengths inside fitting window [nm]: 400.0551 400.1873 400.3194 400.4515 400.5836 400.7157 400.8478 400.9799 401.1119 401.2440 401.3760 401.5080 401.6400 401.7720 401.9039 402.0359 402.1678 402.2998 402.4317 402.5636 402.6955 402.8273 402.9592 403.0910 403.2229 403.3547 403.4865 403.6183 403.7500 403.8818 404.0135 404.1453 404.2770 404.4087 404.5404 404.6720 404.8037 404.9354 405.0670 405.1986 405.3302 405.4618 405.5934 405.7249 405.8565 405.9880 406.1195 406.2510 406.3825 406.5140 406.6455 406.7769 406.9083 407.0398 407.1712 407.3025 407.4339 407.5653 407.6966 407.8280 407.9593 408.0906 408.2219 408.3532 408.4844 408.6157 408.7469 408.8781 409.0093 409.1405 409.2717 409.4029 409.5340 409.6651 409.7963 409.9274 410.0585 410.1895 410.3206 410.4516 410.5827 410.7137 410.8447 410.9757 411.1067 411.2376 411.3686 411.4995 411.6304 411.7613 411.8922 412.0231 412.1540 412.2848 412.4156 412.5465 412.6773 412.8081 412.9388 413.0696 413.2003 413.3311 413.4618 413.5925 413.7232 413.8539 413.9845 414.1152 414.2458 414.3764 414.5070 414.6376 414.7682 414.8988 415.0293 415.1598 415.2903 415.4209 415.5513 415.6818 415.8123 415.9427 416.0731 416.2036 416.3340 416.4644 416.5947 416.7251 416.8554 416.9858 417.1161 417.2464 417.3767 417.5069 417.6372 417.7674 417.8977 418.0279 418.1581 418.2882 418.4184 418.5486 418.6787 418.8088 418.9390 419.0690 419.1991 419.3292 419.4593 419.5893 419.7193 419.8493 419.9793 420.1093 420.2393 420.3692 420.4992 420.6291 420.7590 420.8889 421.0188 421.1486 421.2785 421.4083 421.5381 421.6679 421.7977 421.9275 422.0573 422.1870 422.3167 422.4465 422.5762 422.7059 422.8355 422.9652 423.0948 423.2245 423.3541 423.4837 423.6133 423.7428 423.8724 424.0019 424.1315 424.2610 424.3905 424.5200 424.6494 424.7789 424.9083 425.0377 425.1671 425.2965 425.4259 425.5553 425.6846 425.8140 425.9433 426.0726 426.2019 426.3312 426.4604 426.5897 426.7189 426.8481 426.9773 427.1065 427.2357 427.3649 427.4940 427.6231 427.7523 427.8814 428.0104 428.1395 428.2686 428.3976 428.5266 428.6556 428.7846 428.9136 429.0426 429.1715 429.3005 429.4294 429.5583 429.6872 429.8161 429.9449 430.0738 430.2026 430.3314 430.4603 430.5890 430.7178 430.8466 430.9753 431.1040 431.2328 431.3615 431.4901 431.6188 431.7475 431.8761 432.0047 432.1334 432.2619 432.3905 432.5191 432.6476 432.7762 432.9047 433.0332 433.1617 433.2902 433.4186 433.5471 433.6755 433.8039 433.9323 434.0607 434.1891 434.3175 434.4458 434.5741 434.7024 434.8307 434.9590 435.0873 435.2155 435.3438 435.4720 435.6002 435.7284 435.8566 435.9847 436.1129 436.2410 436.3691 436.4972 436.6253 436.7534 436.8815 437.0095 437.1375 437.2655 437.3935 437.5215 437.6495 437.7774 437.9054 438.0333 438.1612 438.2891 438.4170 438.5448 438.6727 438.8005 438.9283 439.0561 439.1839 439.3117 439.4394 439.5672 439.6949 439.8226 439.9503 440.0780 440.2057 440.3333 440.4610 440.5886 440.7162 440.8438 440.9713 441.0989 441.2264 441.3540 441.4815 441.6090 441.7365 441.8639 441.9914 442.1188 442.2463 442.3737 442.5011 442.6284 442.7558 442.8832 443.0105 443.1378 443.2651 443.3924 443.5197 443.6469 443.7742 443.9014 444.0286 444.1558 444.2830 444.4101 444.5373 444.6644 444.7916 444.9187 445.0457 445.1728 445.2999 445.4269 445.5540 445.6810 445.8080 445.9349 446.0619 446.1889 446.3158 446.4427 446.5696 446.6965 446.8234 446.9503 447.0771 447.2039 447.3308 447.4576 447.5843 447.7111 447.8379 447.9646 448.0913 448.2180 448.3447 448.4714 448.5981 448.7247 448.8513 448.9780 449.1046 449.2311 449.3577 449.4843 449.6108 449.7373 449.8638 449.9903 450.1168 450.2433 450.3697 450.4961 450.6226 450.7490 450.8753 451.0017 451.1281 451.2544 451.3807 451.5070 451.6333 451.7596 451.8859 452.0121 452.1384 452.2646 452.3908 452.5170 452.6431 452.7693 452.8954 453.0215 453.1477 453.2737 453.3998 453.5259 453.6519 453.7780 453.9040 454.0300 454.1560 454.2819 454.4079 454.5338 454.6598 454.7857 454.9116 455.0374 455.1633 455.2891 455.4150 455.5408 455.6666 455.7924 455.9181 456.0439 456.1696 456.2953 456.4210 456.5467 456.6724 456.7981 456.9237 457.0493 457.1750 457.3006 457.4261 457.5517 457.6772 457.8028 457.9283 458.0538 458.1793 458.3048 458.4302 458.5557 458.6811 458.8065 458.9319 459.0573 459.1826 459.3080 459.4333 459.5586 459.6839 459.8092 459.9345 460.0597 460.1850 460.3102 460.4354 460.5606 460.6858 460.8109 460.9361 461.0612 461.1863 461.3114 461.4365 461.5616 461.6866 461.8117 461.9367 462.0617 462.1867 462.3117 462.4366 462.5616 462.6865 462.8114 462.9363 463.0612 463.1860 463.3109 463.4357 463.5605 463.6853 463.8101 463.9349 464.0596 464.1844 464.3091 464.4338 464.5585 464.6832 464.8078 464.9325 465.0571 465.1817 465.3063 465.4309 465.5554 465.6800 465.8045 465.9290 466.0535 466.1780 466.3025 466.4270 466.5514 466.6758 466.8002 466.9246 467.0490 467.1733 467.2977 467.4220 467.5463 467.6706 467.7949 467.9192 468.0434 468.1676 468.2919 468.4161 468.5403 468.6644 468.7886 468.9127 469.0368 469.1609 469.2850 469.4091 469.5332 469.6572 469.7812 469.9052 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Temperature at electronics board [°C], 999=no temperature signal Column 159: Spectrometer control temperature [°C], 999=no temperature signal Column 160: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 161: Temperature in head sensor [°C], 999=no temperature signal Column 162: Humidity in head sensor [%], -9=no humidity signal Column 163: Pressure in head sensor [hPa], -9=no pressure signal Columns 164-709: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 710-1255: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20211007T232719.1Z 7950.977304 104 1 1.96 2 66.79 116.34 86.51 107.13 0.00 1 0.00 1 0 33 2.079e-03 2.000e-03 1.746e-03 1.718e-03 4.750233e+03 3.483931e+02 3.772250e+02 3.155502e+02 4.228125e+02 288.70 -2.00 20.00 -2.00 445.34 0.00e+00 -1.814157e-04 1.855636e-04 4.312431e-06 1.237656e-05 2.230926e-04 288.70 -2.00 20.00 -2.00 454.71 0.00e+00 2.413241e-04 1.512006e-05 1.566348e-06 7.571102e-06 1.850585e-05 226.03 -2.00 2.09 -2.00 435.18 0.00e+00 6.727034e+05 2.412815e+05 4.595226e+04 1.867407e+05 2.996687e+05 269.22 -2.00 10.93 -2.00 457.68 0.00e+00 3.938794e-01 4.878633e-02 2.368555e-03 7.374530e-03 6.467769e-02 227.42 -2.00 3.40 -2.00 454.03 0.00e+00 -4.241107e-06 6.101056e-06 6.832757e-07 9.336367e-07 7.850920e-06 288.70 -2.00 20.00 -2.00 455.38 0.00e+00 2.518 0.000 397.00 473.00 4 4.9730e+00 1.7974e-03 6.3970e-03 3.2434e-04 2.1035e-03 3.0993e-02 2.1432e-03 1.3394e-03 1.9010e-04 2.5843e-03 -1.9917e-03 1.2230e-03 1.8228e-04 8.4545e-05 1.4673e-03 -2.0335e-04 4.1628e-04 2.5148e-05 2.2090e-05 5.0183e-04 2.7261e-04 2.1461e-04 1.1352e-05 1.1784e-05 2.5360e-04 7.3268e-03 -1.2295e-03 1.1125e-03 1.8328e-05 3.7761e-05 1.2204e-03 -3.4560e-04 1.6589e-05 5.5192e-07 2.9789e-07 1.9905e-05 -8.2678e-05 2.2713e-05 7.3318e-07 3.3367e-07 2.7098e-05 2.4981e-02 -3.2143e-04 -1.1688e-02 1.5603e-01 2.0608e-03 2.6687e-03 1.7848e-01 12 9 9 12 1 1 -1850.67 17.56 1.48 0.02498 0.02442 3 25 1 4 0 448.750 19.85 15.00 17.56 30.18 13.5 1023.48 -190 -195 507 113 25 -99 204 -428 -24 -22 14 6 278 135 351 42 60 -313 94 -217 -123 -199 -50 437 175 83 -129 214 23 -86 -129 51 -240 4 -62 168 -17 -312 71 38 18 17 118 488 208 -29 21 -412 -9 -16 212 -143 -176 275 75 471 282 53 27 130 -60 -310 142 237 23 370 138 1 -376 -79 277 -255 -296 -478 -274 -749 -620 -448 -398 -231 -561 -757 -62 -279 -306 108 -19 -17 -19 59 -2 -218 -24 94 349 316 92 381 -5 73 154 -94 537 209 232 153 91 -157 194 -19 326 71 160 -60 197 349 -297 -15 241 -63 -22 -164 175 -257 -133 -19 141 218 0 191 -182 14 135 -135 -16 -294 228 -255 -166 19 -205 -382 -257 221 -133 104 -27 44 -46 284 194 250 27 49 269 478 -158 -61 148 261 -114 -168 -189 108 176 178 201 -27 -114 -78 -151 88 -249 -114 24 -202 -60 -221 40 45 53 307 -156 200 -146 76 -33 -257 17 -60 166 -39 155 113 -68 119 74 -31 -59 -10 17 26 137 49 91 97 72 -313 5 8 -77 -61 172 78 15 -99 251 151 102 584 34 -140 4 -174 257 125 62 -280 473 129 149 71 -217 114 281 238 333 -248 347 283 14 435 -196 -30 -110 328 -67 151 -20 5 20 -205 110 -442 -91 -487 -118 -362 -299 -528 -504 -782 -608 -784 -350 -494 -59 97 -313 -254 -50 -111 -170 -197 -363 130 85 -174 447 -27 -198 -329 -98 137 107 -48 188 83 409 105 132 416 560 6 -108 507 124 510 137 4 -11 208 -116 426 0 240 -44 104 178 10 149 67 -142 179 216 -51 -11 -174 -21 108 -21 -206 -396 -255 151 -121 168 -36 -288 -48 -122 171 -104 92 -25 -3 276 84 79 190 114 121 -113 -3 322 -57 82 116 348 -12 97 -115 135 -161 -9 -92 -199 -57 -84 225 -23 -169 -346 21 -40 231 5 2 111 129 -279 97 -57 -91 62 175 203 -227 151 -93 -191 -172 -24 231 243 80 -506 -94 74 76 -179 42 -299 85 -94 113 0 -34 -101 -286 95 99 -165 -17 -101 -67 -64 144 -34 -138 93 147 -20 -111 53 23 -76 -143 223 88 -277 223 290 -312 -89 -16 -92 217 -183 199 -229 -106 -50 253 32 217 88 121 -114 -160 263 -356 327 29 141 -319 72 169 89 -40 210 -182 -25 27 -205 -129 -298 88 115 -93 -124 33 -107 303 71 -43 6 11 46 -63 21 -93 -158 58 -161 57 153 106 -48 91 57 -152 20 24 33 -108 -56 171 -96 -133 103 193 1 8 131 223 319 -45 -62 268 112 -330 -187 -79 94 -39 -9 71 -182 -195 29 4 140 -96 243 52 -86 33 -362 47 -81 267 -134 289 21 -90 -58 76 215 -34 -103 -7 86 -149 -18 -78 32 -49 -87 -148 -91 107 116 127 -49 -116 -160 -166 423 94 21 -82 172 -368 -21 -19 12 5 241 118 307 37 54 -277 83 -196 -111 -177 -44 374 144 70 -111 189 21 -78 -117 47 -209 3 -51 141 -15 -282 65 34 17 15 105 430 182 -25 19 -355 -7 -14 187 -130 -159 244 67 415 256 47 23 115 -55 -288 133 219 21 350 132 1 -368 -76 268 -241 -280 -440 -247 -654 -530 -378 -337 -205 -523 -712 -59 -266 -295 107 -19 -17 -19 58 -2 -216 -24 92 339 313 91 372 -5 68 146 -89 508 203 235 154 90 -154 186 -18 309 70 157 -59 193 345 -292 -15 231 -61 -22 -163 174 -262 -136 -19 140 219 0 185 -177 13 127 -128 -16 -283 220 -246 -160 18 -197 -372 -250 215 -126 104 -27 44 -45 273 183 232 24 46 259 461 -155 -62 148 261 -115 -171 -189 108 173 173 198 -27 -115 -78 -145 79 -222 -100 21 -193 -59 -219 40 42 51 291 -151 194 -144 75 -33 -254 16 -57 156 -38 146 108 -67 115 72 -30 -56 -10 16 25 137 48 90 94 66 -283 4 7 -72 -59 166 75 14 -95 237 145 97 540 31 -126 4 -161 237 117 58 -250 396 104 119 57 -173 91 226 185 254 -192 276 242 13 421 -198 -31 -113 338 -67 144 -18 4 18 -196 108 -447 -92 -497 -119 -360 -284 -477 -440 -680 -535 -713 -336 -483 -59 97 -312 -246 -49 -106 -164 -194 -360 130 87 -174 455 -28 -205 -338 -99 139 107 -48 181 80 396 101 130 418 546 6 -96 448 109 466 130 3 -11 200 -112 419 0 239 -44 103 174 9 142 64 -135 169 210 -51 -11 -177 -21 106 -21 -205 -404 -265 156 -123 167 -36 -291 -48 -123 174 -105 90 -24 -3 272 84 80 191 115 120 -111 -3 328 -57 82 116 350 -12 93 -110 127 -153 -9 -89 -192 -57 -83 226 -23 -168 -347 20 -41 234 5 3 115 131 -281 97 -56 -91 63 181 208 -228 153 -95 -195 -173 -24 232 247 83 -519 -97 77 81 -189 44 -316 90 -101 120 0 -36 -106 -299 99 103 -172 -18 -106 -69 -65 145 -34 -135 92 146 -20 -112 54 24 -79 -151 236 94 -292 233 301 -328 -91 -16 -94 222 -189 206 -240 -113 -53 274 34 237 95 130 -122 -174 282 -388 352 31 152 -350 79 186 96 -43 227 -195 -27 29 -222 -139 -326 97 127 -102 -136 36 -118 332 77 -47 7 12 51 -70 23 -104 -180 66 -184 65 172 119 -54 103 66 -172 22 27 38 -123 -64 195 -110 -152 118 224 1 10 150 254 360 -51 -71 308 129 -376 -213 -89 105 -44 -10 81 -209 -228 33 4 163 -114 288 61 -100 38 -411 52 -91 297 -154 331 24 -106 -67 90 253 -39 -118 -8 100 -176 -20 -91 38 -57 -102 -174 -107 127 136 151 -58 -134