File name: Pandora150s1_Ulsan_20241016_L2Fit_ffus5c13d20240624p1-8.txt File generation date: 20241126T171925.6Z Data description: Level 2 spectral fitting results file Data file version: ffus5c13p1-8 Local principal investigator: Chang Keun Song Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 150 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora150_OF_v4d20210223.txt Instrument calibration file used: Pandora150s1_CF_v13d20240624.txt Level 1 file used: Pandora150s1_Ulsan_20241016_L1_smca1c13d20240624p1-8.txt Full location name: Ulsan National Institute of Science and Technology, UNIST Short location name: Ulsan Country of location: South Korea Location latitude [deg]: 35.5745 Location longitude [deg]: 129.1896 Location altitude [m]: 38 Local noon date: 20241016 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 357 622 Nominal wavelengths inside fitting window [nm]: 322.6090 322.7484 322.8878 323.0272 323.1666 323.3059 323.4453 323.5846 323.7239 323.8632 324.0025 324.1418 324.2811 324.4204 324.5596 324.6989 324.8381 324.9773 325.1165 325.2557 325.3949 325.5341 325.6732 325.8124 325.9515 326.0906 326.2298 326.3689 326.5080 326.6470 326.7861 326.9252 327.0642 327.2032 327.3423 327.4813 327.6203 327.7593 327.8982 328.0372 328.1762 328.3151 328.4540 328.5929 328.7318 328.8707 329.0096 329.1485 329.2874 329.4262 329.5650 329.7039 329.8427 329.9815 330.1203 330.2590 330.3978 330.5366 330.6753 330.8140 330.9527 331.0915 331.2301 331.3688 331.5075 331.6462 331.7848 331.9234 332.0621 332.2007 332.3393 332.4779 332.6164 332.7550 332.8936 333.0321 333.1706 333.3092 333.4477 333.5862 333.7246 333.8631 334.0016 334.1400 334.2785 334.4169 334.5553 334.6937 334.8321 334.9705 335.1088 335.2472 335.3855 335.5238 335.6622 335.8005 335.9387 336.0770 336.2153 336.3536 336.4918 336.6300 336.7683 336.9065 337.0447 337.1828 337.3210 337.4592 337.5973 337.7355 337.8736 338.0117 338.1498 338.2879 338.4260 338.5640 338.7021 338.8401 338.9782 339.1162 339.2542 339.3922 339.5302 339.6681 339.8061 339.9440 340.0820 340.2199 340.3578 340.4957 340.6336 340.7715 340.9093 341.0472 341.1850 341.3228 341.4606 341.5984 341.7362 341.8740 342.0118 342.1495 342.2873 342.4250 342.5627 342.7004 342.8381 342.9758 343.1135 343.2511 343.3888 343.5264 343.6640 343.8016 343.9392 344.0768 344.2144 344.3519 344.4895 344.6270 344.7645 344.9020 345.0395 345.1770 345.3145 345.4520 345.5894 345.7268 345.8643 346.0017 346.1391 346.2765 346.4138 346.5512 346.6885 346.8259 346.9632 347.1005 347.2378 347.3751 347.5124 347.6497 347.7869 347.9241 348.0614 348.1986 348.3358 348.4730 348.6102 348.7473 348.8845 349.0216 349.1588 349.2959 349.4330 349.5701 349.7071 349.8442 349.9813 350.1183 350.2553 350.3924 350.5294 350.6664 350.8033 350.9403 351.0773 351.2142 351.3511 351.4881 351.6250 351.7619 351.8987 352.0356 352.1725 352.3093 352.4461 352.5830 352.7198 352.8566 352.9933 353.1301 353.2669 353.4036 353.5404 353.6771 353.8138 353.9505 354.0872 354.2238 354.3605 354.4971 354.6338 354.7704 354.9070 355.0436 355.1802 355.3167 355.4533 355.5898 355.7264 355.8629 355.9994 356.1359 356.2724 356.4088 356.5453 356.6817 356.8182 356.9546 357.0910 357.2274 357.3638 357.5001 357.6365 357.7728 357.9092 358.0455 358.1818 358.3181 358.4544 358.5906 358.7269 358.8631 358.9993 359.1356 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Temperature at electronics board [°C], 999=no temperature signal Column 165: Spectrometer control temperature [°C], 999=no temperature signal Column 166: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 167: Temperature in head sensor [°C], 999=no temperature signal Column 168: Humidity in head sensor [%], -9=no humidity signal Column 169: Pressure in head sensor [hPa], -9=no pressure signal Columns 170-435: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 436-701: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------