File name: Pandora218s1_Vientiane_20240523_L2Fit_fsus1c3d20230614p1-8.txt File generation date: 20250723T094252.5Z Data description: Level 2 spectral fitting results file Data file version: fsus1c3p1-8 Local principal investigator: Virasith Phomsouvanh Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 218 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora218_OF_v3d20220124.txt Instrument calibration file used: Pandora218s1_CF_v3d20230614.txt Level 1 file used: Pandora218s1_Vientiane_20240523_L1_smca1c3d20230614p1-8.txt Full location name: Laos Ministry of Natural Resources and Environment Short location name: Vientiane Country of location: Lao People's Democratic Republic Location latitude [deg]: 17.9979 Location longitude [deg]: 102.5821 Location altitude [m]: 169 Local noon date: 20240523 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 208 352 Nominal wavelengths inside fitting window [nm]: 306.0478 306.1890 306.3302 306.4714 306.6125 306.7537 306.8949 307.0360 307.1771 307.3182 307.4593 307.6004 307.7415 307.8826 308.0236 308.1647 308.3057 308.4467 308.5877 308.7287 308.8697 309.0107 309.1517 309.2926 309.4336 309.5745 309.7154 309.8564 309.9973 310.1381 310.2790 310.4199 310.5607 310.7016 310.8424 310.9832 311.1241 311.2649 311.4056 311.5464 311.6872 311.8279 311.9687 312.1094 312.2501 312.3908 312.5315 312.6722 312.8129 312.9536 313.0942 313.2349 313.3755 313.5161 313.6567 313.7973 313.9379 314.0785 314.2190 314.3596 314.5001 314.6407 314.7812 314.9217 315.0622 315.2026 315.3431 315.4836 315.6240 315.7645 315.9049 316.0453 316.1857 316.3261 316.4665 316.6068 316.7472 316.8875 317.0279 317.1682 317.3085 317.4488 317.5891 317.7294 317.8696 318.0099 318.1501 318.2904 318.4306 318.5708 318.7110 318.8512 318.9913 319.1315 319.2716 319.4118 319.5519 319.6920 319.8321 319.9722 320.1123 320.2524 320.3924 320.5325 320.6725 320.8125 320.9525 321.0925 321.2325 321.3725 321.5125 321.6524 321.7924 321.9323 322.0722 322.2121 322.3520 322.4919 322.6318 322.7716 322.9115 323.0513 323.1911 323.3310 323.4708 323.6106 323.7503 323.8901 324.0299 324.1696 324.3093 324.4491 324.5888 324.7285 324.8682 325.0078 325.1475 325.2871 325.4268 325.5664 325.7060 325.8456 325.9852 326.1248 326.2644 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-304: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 305-449: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20240523T070634.4Z 8909.296232 523 1 48.61 2 28.42 280.38 147.96 105.72 0.00 1 0.00 1 0 33 4.676e-03 3.350e-03 2.372e-03 1.698e-03 -2.890271e-06 7.007489e-07 5.303413e-08 4.319037e-07 2.303856e-06 229.60 -2.00 3.11 -2.00 320.43 0.00e+00 1.164304e-03 2.291249e-04 2.770051e-05 1.273928e-05 6.067307e-04 293.87 -2.00 20.00 -2.00 319.91 0.00e+00 1.384648e-03 3.265976e-04 1.081556e-05 2.865738e-05 1.016775e-03 293.87 -2.00 20.00 -2.00 320.66 0.00e+00 7.523624e-04 4.222660e-04 5.294584e-05 1.111727e-05 1.095891e-03 293.87 -2.00 20.00 -2.00 320.35 0.00e+00 1.609944e-01 2.181621e-03 1.301532e-04 6.888094e-03 6.124586e-03 210.49 3.20 0.00 0.69 10.59 315.69 0.00e+00 -3.650866e-05 9.492182e-05 2.229096e-05 8.499219e-06 1.648106e-04 293.87 -2.00 20.00 -2.00 314.60 0.00e+00 1.137 0.000 303.00 329.40 4 5.9473e+00 5.8108e-03 1.0821e-02 2.1788e-03 1.9569e-02 2.3237e-02 7.2479e-03 1.3192e-03 2.7875e-04 2.0850e-02 1.5334e-02 4.2195e-03 4.2979e-04 7.6286e-05 1.1703e-02 -3.3498e-03 1.5628e-03 1.0588e-04 2.5937e-05 4.1982e-03 -2.6118e-03 1.1966e-03 8.4678e-05 3.9925e-05 2.7451e-03 4.7183e-04 -1.5867e-05 1.4770e-03 1.2054e-04 1.7901e-05 2.7539e-03 -1.2354e-04 5.6344e-05 2.7052e-06 8.7765e-07 1.6413e-04 -6.6398e-03 0.0000e+00 1.7883e+00 1.9740e-01 6.8081e-03 1.0209e-03 4.7641e-01 12 8 8 10 0 0 99.95 23.65 0.45 -0.00664 -0.00758 14 3 1 5 0 3471.660 26.00 20.00 23.65 30.80 10.5 976.42 -1054 -1153 437 -440 941 666 1173 -116 532 672 305 93 -898 -263 -410 -175 -727 -247 474 -603 42 398 1107 1513 -1695 551 6 -655 770 80 -257 399 -207 -249 111 -195 11 -153 61 290 -1013 185 -342 1270 -253 48 -11 -179 89 -155 61 -282 349 80 274 -91 81 55 374 -992 -102 29 -158 -336 135 58 -132 67 385 86 82 -577 957 -376 -249 -312 -104 433 361 241 -18 249 -5 -184 -21 -81 -266 -445 405 75 295 306 322 119 407 -969 -33 -604 -116 317 35 71 44 -79 -16 84 -424 1 -100 65 27 -444 -184 -196 304 -144 185 -110 579 52 -58 -177 -485 -73 -83 179 -281 716 -100 210 312 133 -262 -174 192 -25 -79 -155 88 130 56 188 -68 -246 -60 -324 -351 138 -141 328 225 433 -47 232 302 140 44 -432 -127 -199 -85 -369 -130 251 -322 21 185 490 675 -813 269 3 -324 370 42 -153 251 -150 -181 83 -150 9 -118 46 214 -726 138 -252 945 -185 37 -9 -146 73 -128 50 -231 285 68 244 -80 73 49 333 -831 -82 25 -146 -314 131 56 -124 63 328 73 66 -482 800 -352 -235 -315 -110 450 399 278 -22 292 -5 -205 -21 -82 -261 -454 415 84 333 357 369 129 445 -1046 -36 -676 -136 388 44 89 57 -104 -21 104 -522 1 -115 75 30 -538 -236 -257 394 -182 222 -134 667 59 -66 -210 -565 -87 -102 223 -365 969 -133 287 434 185 -358 -232 249 -33 -106 -222 128 200 86 302 -111 -402 -97 SS 20240523T073949.9Z 8909.319327 542 1 49.16 2 36.19 280.67 140.70 105.54 0.00 1 0.00 1 0 49 1.177e-03 8.719e-04 9.262e-04 6.697e-04 -9.569167e-07 2.752666e-07 1.901079e-08 4.319174e-07 5.805957e-07 229.60 -2.00 3.11 -2.00 320.46 0.00e+00 3.877976e-04 8.919158e-05 1.106390e-05 1.273587e-05 1.524359e-04 293.87 -2.00 20.00 -2.00 319.87 0.00e+00 5.684219e-05 1.286090e-04 3.398111e-06 2.866505e-05 2.553424e-04 293.87 -2.00 20.00 -2.00 320.66 0.00e+00 2.332222e-04 1.631353e-04 4.185538e-06 1.113261e-05 2.758386e-04 293.87 -2.00 20.00 -2.00 320.35 0.00e+00 1.725054e-01 8.801630e-04 3.577349e-05 6.888071e-03 1.550245e-03 221.67 1.23 0.00 0.46 2.67 315.70 0.00e+00 -1.000110e-05 3.769985e-05 2.251690e-06 8.505816e-06 4.148526e-05 293.87 -2.00 20.00 -2.00 314.57 0.00e+00 1.238 0.000 303.00 329.40 4 4.0839e+00 2.4988e-03 1.1768e-02 2.1785e-03 4.9404e-03 2.3061e-02 3.0932e-03 1.2167e-03 2.8032e-04 5.2746e-03 3.8622e-04 1.7317e-03 1.5849e-04 7.5492e-05 2.9531e-03 -1.5599e-03 6.3614e-04 3.5716e-05 2.5634e-05 1.0720e-03 4.0586e-04 4.6844e-04 3.2433e-05 3.9462e-05 6.8933e-04 2.7335e-03 1.3714e-03 5.4660e-04 3.7968e-05 1.6241e-05 6.3930e-04 8.7533e-05 2.1781e-05 1.4391e-06 8.8764e-07 4.1397e-05 -8.1154e-03 0.0000e+00 6.5830e-01 7.6034e-02 2.4874e-03 9.8548e-04 1.1672e-01 10 0 0 10 0 0 99.85 23.65 0.37 -0.00812 -0.00745 71 15 1 5 0 692.230 26.00 20.00 23.65 32.15 10.5 986.12 -26 -151 -92 -14 393 162 168 -78 351 147 40 -1 50 10 -314 -75 -309 -240 73 116 77 216 225 -54 -289 -51 -199 -35 271 40 -91 30 -279 -124 0 9 -77 20 36 148 -72 -223 -54 240 137 42 49 -27 57 10 -36 58 -119 55 46 -22 -21 -27 72 -130 -50 -168 31 41 108 -35 8 -8 203 124 -23 57 80 -169 -38 45 -2 110 143 20 -7 29 61 -153 1 -99 -144 -31 48 109 62 18 -91 98 -22 -211 9 -25 -166 11 25 -56 96 -48 29 55 -73 -62 24 -43 9 -64 -89 -7 75 -23 81 30 71 -11 -22 -148 -99 8 4 23 -28 141 60 90 -5 22 -24 6 -6 -9 20 3 61 17 55 41 -97 -61 -39 -8 -51 -30 -5 130 57 65 -33 149 65 18 0 23 5 -150 -36 -154 -124 38 61 38 108 108 -26 -148 -25 -101 -17 141 21 -55 19 -193 -93 0 7 -58 15 29 113 -53 -160 -39 175 105 34 38 -21 46 8 -29 47 -97 46 40 -20 -19 -24 64 -108 -40 -142 29 39 107 -35 8 -8 174 103 -19 47 68 -159 -37 46 -2 120 157 23 -8 34 68 -166 1 -96 -135 -30 51 120 70 22 -104 112 -24 -222 10 -28 -196 14 31 -71 126 -61 37 70 -90 -71 28 -49 10 -79 -110 -9 94 -29 99 34 82 -12 -25 -176 -117 10 5 29 -36 187 79 122 -6 30 -32 8 -8 -12 27 4 89 27 86 66 -156 -98 -62 SS 20240523T074423.1Z 8909.322490 545 1 21.06 2 37.26 280.75 139.70 105.56 0.00 1 0.00 1 0 49 1.768e-03 1.416e-03 1.843e-03 1.301e-03 -1.497847e-06 5.325094e-07 2.267672e-08 4.319028e-07 8.719397e-07 229.60 -2.00 3.11 -2.00 320.49 0.00e+00 4.639184e-04 1.737707e-04 3.932719e-06 1.275085e-05 2.288302e-04 293.87 -2.00 20.00 -2.00 319.92 0.00e+00 2.517953e-04 2.494438e-04 5.942589e-06 2.867243e-05 3.835254e-04 293.87 -2.00 20.00 -2.00 320.69 0.00e+00 -3.590351e-04 3.194995e-04 6.244078e-06 1.114261e-05 4.142386e-04 293.87 -2.00 20.00 -2.00 320.39 0.00e+00 1.743673e-01 1.714256e-03 5.659033e-05 6.888418e-03 2.329751e-03 221.27 2.38 0.00 0.46 4.01 315.80 0.00e+00 1.031227e-05 7.440385e-05 3.561930e-06 8.509882e-06 6.232147e-05 293.87 -2.00 20.00 -2.00 314.67 0.00e+00 1.255 0.000 303.00 329.40 4 4.4803e+00 4.8388e-03 1.1931e-02 2.1785e-03 7.4293e-03 4.0417e-02 6.0289e-03 1.2404e-03 2.8022e-04 7.9227e-03 1.8202e-03 3.3728e-03 1.3029e-04 7.5362e-05 4.4361e-03 -2.1678e-03 1.2404e-03 3.6335e-05 2.6004e-05 1.6109e-03 8.3016e-04 9.2199e-04 9.8702e-06 4.0656e-05 1.0354e-03 1.8098e-03 -6.3143e-04 1.0854e-03 3.6501e-05 1.7023e-05 9.7277e-04 1.0256e-04 4.2402e-05 1.6265e-06 8.7975e-07 6.2132e-05 -7.4462e-03 0.0000e+00 5.2682e-01 1.4759e-01 9.1752e-04 9.8168e-04 1.7496e-01 12 9 1 12 1 1 99.99 23.65 0.32 -0.00745 -0.00666 27 14 1 5 0 752.070 26.00 20.00 23.65 32.40 10.5 988.26 303 -480 -103 152 22 87 430 -15 -168 465 -128 215 21 9 -335 -202 -443 111 120 -149 45 43 186 274 -388 -4 -248 -74 -49 358 243 -13 84 -287 -89 186 -190 -18 -139 94 -319 -12 81 418 102 41 -37 -40 -11 75 139 -14 -174 403 175 12 -166 73 41 -413 -86 75 -216 -104 -7 78 -80 -22 23 14 273 -44 213 -285 -84 146 -5 -42 184 64 131 184 -170 -82 12 -17 -275 -12 48 10 84 155 -131 180 15 -375 98 -139 -244 -192 200 52 110 108 -101 -32 28 13 -129 107 5 -142 -146 -43 143 -98 209 93 254 -31 -77 -61 -135 -82 41 44 -65 225 -99 85 15 9 35 -19 -30 -5 -198 -15 34 47 -9 120 -22 -67 -1 85 -148 -33 49 7 30 165 -6 -70 199 -56 96 10 4 -156 -95 -216 56 62 -76 22 20 88 131 -179 -2 -123 -36 -23 182 141 -8 56 -209 -67 143 -147 -14 -106 69 -228 -9 59 292 75 31 -29 -33 -9 63 116 -12 -144 343 148 11 -154 67 35 -351 -71 65 -193 -100 -7 78 -77 -19 20 11 224 -35 185 -257 -82 143 -5 -45 200 73 153 213 -189 -89 12 -16 -261 -12 48 11 94 180 -150 206 16 -395 107 -164 -286 -234 254 65 142 144 -133 -41 34 16 -147 123 6 -173 -188 -53 185 -123 251 112 291 -34 -86 -72 -158 -100 51 55 -85 293 -135 119 21 13 49 -26 -40 -7 -271 -22 51 72 -14 190 -35 -108 -2 SS 20240523T075513.8Z 8909.330020 554 1 11.14 2 39.79 280.98 137.33 105.67 0.00 1 0.00 1 0 33 1.351e-03 8.716e-04 1.071e-03 7.704e-04 -7.143512e-07 3.161622e-07 1.867423e-08 4.319220e-07 6.667026e-07 229.60 -2.00 3.11 -2.00 320.50 0.00e+00 4.146622e-04 1.027777e-04 1.085198e-05 1.274405e-05 1.749368e-04 293.87 -2.00 20.00 -2.00 319.95 0.00e+00 3.088478e-04 1.474871e-04 4.734584e-06 2.867634e-05 2.927388e-04 293.87 -2.00 20.00 -2.00 320.70 0.00e+00 -3.397751e-04 1.872326e-04 1.700736e-05 1.114384e-05 3.165640e-04 293.87 -2.00 20.00 -2.00 320.39 0.00e+00 1.820634e-01 1.020806e-03 4.106416e-05 6.887854e-03 1.783252e-03 225.13 1.37 0.00 0.42 3.07 315.74 0.00e+00 -3.296754e-05 4.336302e-05 7.097884e-06 8.505234e-06 4.760937e-05 293.87 -2.00 20.00 -2.00 314.61 0.00e+00 1.300 0.000 303.00 329.40 4 2.8276e+00 2.9463e-03 1.2358e-02 2.1788e-03 5.6722e-03 2.5396e-02 3.6535e-03 1.2958e-03 2.8166e-04 6.0635e-03 -4.0107e-03 2.0174e-03 1.6450e-04 7.6229e-05 3.3921e-03 -1.3940e-03 7.4103e-04 3.6044e-05 2.5972e-05 1.2410e-03 1.1588e-03 5.4165e-04 3.2935e-05 4.0014e-05 7.9131e-04 8.9887e-03 -1.6960e-03 5.9949e-04 3.8747e-05 1.5901e-05 7.0423e-04 7.1909e-05 2.5137e-05 1.5313e-06 8.8799e-07 4.7600e-05 -9.8021e-03 0.0000e+00 6.4193e-01 8.5215e-02 2.2380e-03 9.8252e-04 1.3169e-01 12 1 1 12 1 1 87.46 23.65 0.33 -0.00980 -0.00925 51 49 1 5 0 214.210 26.00 20.01 23.65 33.71 10.4 997.64 -253 -151 -121 -432 641 -94 332 -107 5 140 -53 105 -129 230 -279 -118 -166 -6 -44 394 77 -17 320 130 -94 -93 211 -185 393 -361 87 -112 13 -108 -154 79 -165 -10 90 158 -90 57 18 53 -181 -97 129 -19 36 -40 -5 13 64 51 -85 65 -72 33 -34 -29 35 58 42 21 -28 -10 128 -46 197 74 -106 58 -114 23 -49 -17 -102 -18 -26 43 47 -65 -45 -2 -55 -96 -95 -108 125 59 125 98 -66 -49 -52 80 23 4 -120 38 36 -24 94 -19 34 16 59 -177 104 94 4 -60 -49 37 51 121 -45 -74 42 -111 59 -171 34 -37 -121 -13 35 7 -56 24 96 51 -5 -33 -50 18 -33 94 16 30 -38 26 -34 14 -19 -73 -48 -40 -146 215 -34 131 -43 2 63 -24 49 -62 112 -137 -58 -79 -3 -22 198 40 -8 147 61 -46 -48 111 -96 198 -197 51 -71 9 -80 -118 58 -123 -7 70 119 -65 40 12 38 -138 -77 100 -15 29 -33 -4 10 51 42 -75 58 -66 30 -30 -24 28 49 37 20 -26 -9 123 -41 170 62 -85 48 -98 21 -48 -17 -107 -19 -29 48 54 -74 -52 -2 -56 -95 -91 -108 129 64 145 113 -75 -55 -57 87 24 4 -139 46 45 -31 122 -25 45 20 72 -211 118 106 5 -73 -63 46 63 153 -55 -89 48 -123 66 -201 42 -45 -152 -17 44 10 -75 34 134 71 -7 -45 -68 24 -47 134 23 45 -61 41 -56 23 -31 SS 20240523T081922.7Z 8909.346790 566 1 49.34 2 45.42 281.63 132.06 106.09 0.00 1 0.00 1 0 33 4.676e-03 2.567e-03 3.178e-03 1.760e-03 -1.377822e-06 7.084007e-07 2.447964e-08 4.319617e-07 2.298817e-06 229.60 -2.00 3.11 -2.00 321.15 0.00e+00 5.394926e-04 2.444724e-04 1.261300e-05 1.300931e-05 6.004424e-04 293.87 -2.00 20.00 -2.00 320.71 0.00e+00 1.396442e-03 3.360146e-04 6.161146e-06 2.869084e-05 1.011388e-03 293.87 -2.00 20.00 -2.00 321.16 0.00e+00 4.684229e-04 4.681776e-04 4.670270e-05 1.121730e-05 1.095307e-03 293.87 -2.00 20.00 -2.00 321.03 0.00e+00 1.971448e-01 2.431973e-03 1.072320e-04 6.890598e-03 6.191625e-03 216.23 2.92 0.00 0.44 10.62 316.92 0.00e+00 1.127404e-05 1.245420e-04 4.546122e-06 8.575045e-06 1.649755e-04 293.87 -2.00 20.00 -2.00 315.69 0.00e+00 1.423 0.000 303.00 329.40 4 5.3843e+00 6.3366e-03 1.3526e-02 2.1780e-03 1.9605e-02 5.1900e-02 8.4402e-03 1.4948e-03 2.8383e-04 2.0999e-02 3.6446e-03 4.7456e-03 2.5618e-04 7.3178e-05 1.1687e-02 -4.5848e-03 1.8501e-03 6.5611e-05 3.1158e-05 4.3458e-03 3.2229e-03 1.3498e-03 3.3434e-05 5.0740e-05 2.7492e-03 5.9139e-04 -1.3867e-03 1.5709e-03 6.5961e-05 1.8673e-05 2.2747e-03 -6.1908e-05 5.8924e-05 1.8055e-06 8.7886e-07 1.6433e-04 -7.5984e-03 0.0000e+00 1.4266e+00 1.9755e-01 2.8682e-03 9.3331e-04 4.4247e-01 12 8 8 10 0 0 99.99 23.65 0.39 -0.00760 -0.00807 92 20 1 5 0 536.260 26.00 20.01 23.65 34.22 10.5 999.82 -358 -1037 -898 626 1314 1117 168 409 -410 1674 -312 292 -218 -121 -1398 244 -300 -1249 728 -1049 677 125 1197 597 -1699 -250 -200 153 367 1394 -387 368 -77 -154 -110 -199 121 -57 298 287 64 -404 -412 970 -309 111 -422 -80 -152 171 70 -120 35 546 219 -196 -82 -25 250 -834 319 -268 -101 -77 155 -194 68 69 354 429 144 -73 269 -130 -261 -156 170 47 147 88 -54 50 188 -317 -73 -192 -493 124 -169 70 210 56 143 306 130 -925 14 -184 74 217 38 -132 183 132 -12 166 -265 -57 203 -177 -11 -34 -112 126 213 -112 -124 71 113 -62 2 -273 -225 20 77 281 -310 559 -111 5 54 -42 -216 -41 105 -11 0 -165 -126 227 86 123 -161 -15 -14 -66 -211 -193 134 283 258 43 117 -128 531 -103 98 -75 -42 -499 86 -111 -487 284 -415 251 44 398 204 -624 -95 -78 58 138 557 -180 197 -43 -95 -70 -130 80 -37 192 181 39 -241 -244 584 -199 75 -296 -57 -111 125 51 -87 26 406 173 -166 -72 -21 201 -634 235 -207 -86 -71 148 -186 62 59 275 305 109 -52 210 -113 -248 -158 165 48 161 101 -63 58 209 -327 -75 -183 -457 120 -178 74 240 66 167 336 147 -1025 16 -206 87 268 49 -177 256 175 -15 225 -335 -67 225 -198 -13 -43 -147 169 283 -145 -153 83 137 -73 2 -341 -271 25 99 366 -422 794 -166 7 78 -60 -329 -60 151 -16 1 -242 -198 381 153 212 -285 -27 -24 SS 20240523T085002.4Z 8909.368083 592 1 1.80 2 52.54 282.67 125.39 106.91 0.00 1 0.00 1 0 49 4.708e-03 3.373e-03 5.103e-03 3.218e-03 -2.578844e-06 1.305957e-06 4.875151e-08 4.319396e-07 2.322487e-06 229.60 -2.00 3.11 -2.00 320.84 0.00e+00 7.592132e-04 4.377748e-04 2.476951e-05 1.287828e-05 6.026570e-04 293.87 -2.00 20.00 -2.00 320.33 0.00e+00 1.822193e-04 6.061137e-04 1.101697e-05 2.871023e-05 1.017423e-03 293.87 -2.00 20.00 -2.00 320.94 0.00e+00 6.618886e-04 8.222011e-04 4.899020e-05 1.118759e-05 1.102210e-03 293.87 -2.00 20.00 -2.00 320.72 0.00e+00 2.179157e-01 4.390637e-03 1.173283e-04 6.889591e-03 6.284603e-03 218.40 4.76 0.00 0.42 10.74 316.37 0.00e+00 7.316202e-05 2.058559e-04 2.372865e-05 8.554604e-06 1.661459e-04 293.87 -2.00 20.00 -2.00 315.20 0.00e+00 1.640 0.000 303.00 329.40 4 3.2023e+00 1.1657e-02 1.5600e-02 2.1784e-03 1.9792e-02 2.4393e-02 1.5208e-02 1.7881e-03 2.8448e-04 2.1273e-02 8.1339e-03 8.5288e-03 3.4732e-04 7.2806e-05 1.1785e-02 -4.1045e-03 3.4553e-03 9.5011e-05 2.8770e-05 4.4988e-03 6.3968e-04 2.3962e-03 7.7418e-05 4.6200e-05 2.8130e-03 4.1700e-03 -1.7962e-03 2.2733e-03 6.8781e-05 1.3515e-05 1.9137e-03 3.5687e-04 1.0428e-04 2.3838e-06 8.9425e-07 1.6588e-04 -1.0126e-02 0.0000e+00 -2.2178e-02 3.3102e-01 4.1073e-03 8.1000e-04 4.1725e-01 12 9 9 12 1 1 -254.40 23.65 0.36 -0.01013 -0.00740 3 23 1 5 0 448.910 26.00 19.99 23.65 33.67 10.5 996.14 -456 -33 -223 -1235 91 -211 2048 -836 558 605 305 -799 1261 596 -286 -158 399 837 -267 209 -777 485 -585 154 -736 446 -776 -860 719 -1094 538 -118 121 -738 536 -32 -790 -434 106 293 -41 -166 -227 263 -710 -304 995 154 22 134 386 -238 283 655 -141 390 -547 207 -325 283 71 657 -87 -166 277 -464 -404 184 231 401 -333 -226 668 -677 -41 -197 196 24 165 160 48 -105 132 67 -396 301 105 -462 721 156 284 -237 144 -173 18 9 -525 70 -25 -316 -651 509 -410 109 329 -77 -314 -73 156 -51 -367 -430 145 -235 557 -142 308 319 119 314 -371 107 25 -204 27 -51 -223 -26 239 256 40 424 -119 -346 -34 -245 183 391 -408 62 178 159 -315 -5 -34 -105 -8 -59 -337 25 -57 610 -285 204 231 111 -302 478 231 -112 -63 165 360 -119 92 -331 191 -244 66 -310 196 -358 -388 315 -525 271 -70 77 -484 363 -22 -560 -305 73 199 -27 -114 -156 174 -503 -225 759 115 17 102 295 -181 214 509 -117 327 -482 180 -280 227 56 542 -75 -156 256 -431 -380 161 194 327 -264 -186 570 -616 -38 -198 205 25 186 180 55 -120 144 70 -405 300 102 -451 763 174 326 -284 169 -191 20 10 -578 78 -29 -377 -811 655 -534 146 438 -98 -389 -87 178 -58 -443 -529 188 -311 721 -179 389 381 142 363 -438 127 32 -256 35 -67 -292 -35 343 361 57 605 -167 -490 -46 -339 261 569 -620 96 294 266 -538 -9 -57