File name: Pandora140s1_WashingtonDC_20240427_L2Fit_fnvs5c10d20200806p1-8.txt File generation date: 20240429T095730.2Z Data description: Level 2 spectral fitting results file Data file version: fnvs5c10p1-8 Local principal investigator: Luke Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 140 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora140_OF_v3d20200721.txt Instrument calibration file used: Pandora140s1_CF_v10d20200806.txt Level 1 file used: Pandora140s1_WashingtonDC_20240427_L1_smca1c10d20200806p1-8.txt Full location name: McMillan Reservoir Short location name: WashingtonDC Country of location: United States Location latitude [deg]: 38.9218 Location longitude [deg]: -77.0124 Location altitude [m]: 58 Local noon date: 20240427 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 911 1456 Nominal wavelengths inside fitting window [nm]: 400.1283 400.2604 400.3924 400.5244 400.6564 400.7884 400.9204 401.0523 401.1843 401.3162 401.4482 401.5801 401.7120 401.8438 401.9757 402.1076 402.2394 402.3712 402.5030 402.6348 402.7666 402.8984 403.0301 403.1618 403.2936 403.4253 403.5570 403.6887 403.8203 403.9520 404.0836 404.2152 404.3469 404.4784 404.6100 404.7416 404.8732 405.0047 405.1362 405.2677 405.3992 405.5307 405.6622 405.7936 405.9251 406.0565 406.1879 406.3193 406.4507 406.5821 406.7134 406.8448 406.9761 407.1074 407.2387 407.3700 407.5012 407.6325 407.7637 407.8950 408.0262 408.1574 408.2886 408.4197 408.5509 408.6820 408.8132 408.9443 409.0754 409.2064 409.3375 409.4686 409.5996 409.7306 409.8617 409.9927 410.1236 410.2546 410.3856 410.5165 410.6474 410.7783 410.9092 411.0401 411.1710 411.3018 411.4327 411.5635 411.6943 411.8251 411.9559 412.0867 412.2174 412.3482 412.4789 412.6096 412.7403 412.8710 413.0017 413.1323 413.2629 413.3936 413.5242 413.6548 413.7854 413.9159 414.0465 414.1770 414.3075 414.4380 414.5685 414.6990 414.8295 414.9599 415.0904 415.2208 415.3512 415.4816 415.6120 415.7423 415.8727 416.0030 416.1334 416.2637 416.3940 416.5242 416.6545 416.7847 416.9150 417.0452 417.1754 417.3056 417.4358 417.5659 417.6961 417.8262 417.9563 418.0864 418.2165 418.3466 418.4767 418.6067 418.7367 418.8668 418.9968 419.1267 419.2567 419.3867 419.5166 419.6466 419.7765 419.9064 420.0363 420.1661 420.2960 420.4258 420.5557 420.6855 420.8153 420.9450 421.0748 421.2046 421.3343 421.4640 421.5937 421.7234 421.8531 421.9828 422.1124 422.2421 422.3717 422.5013 422.6309 422.7605 422.8900 423.0196 423.1491 423.2787 423.4082 423.5377 423.6671 423.7966 423.9260 424.0555 424.1849 424.3143 424.4437 424.5731 424.7024 424.8318 424.9611 425.0904 425.2197 425.3490 425.4783 425.6075 425.7368 425.8660 425.9952 426.1244 426.2536 426.3827 426.5119 426.6410 426.7702 426.8993 427.0284 427.1574 427.2865 427.4156 427.5446 427.6736 427.8026 427.9316 428.0606 428.1895 428.3185 428.4474 428.5763 428.7052 428.8341 428.9630 429.0919 429.2207 429.3495 429.4783 429.6071 429.7359 429.8647 429.9934 430.1222 430.2509 430.3796 430.5083 430.6370 430.7656 430.8943 431.0229 431.1516 431.2802 431.4087 431.5373 431.6659 431.7944 431.9230 432.0515 432.1800 432.3085 432.4369 432.5654 432.6938 432.8223 432.9507 433.0791 433.2075 433.3358 433.4642 433.5925 433.7208 433.8491 433.9774 434.1057 434.2340 434.3622 434.4904 434.6187 434.7469 434.8751 435.0032 435.1314 435.2595 435.3877 435.5158 435.6439 435.7719 435.9000 436.0281 436.1561 436.2841 436.4121 436.5401 436.6681 436.7961 436.9240 437.0520 437.1799 437.3078 437.4357 437.5635 437.6914 437.8192 437.9471 438.0749 438.2027 438.3305 438.4582 438.5860 438.7137 438.8414 438.9691 439.0968 439.2245 439.3522 439.4798 439.6074 439.7351 439.8627 439.9903 440.1178 440.2454 440.3729 440.5004 440.6280 440.7555 440.8829 441.0104 441.1378 441.2653 441.3927 441.5201 441.6475 441.7749 441.9022 442.0296 442.1569 442.2842 442.4115 442.5388 442.6661 442.7933 442.9206 443.0478 443.1750 443.3022 443.4294 443.5565 443.6837 443.8108 443.9379 444.0650 444.1921 444.3192 444.4462 444.5733 444.7003 444.8273 444.9543 445.0813 445.2082 445.3352 445.4621 445.5890 445.7159 445.8428 445.9697 446.0966 446.2234 446.3502 446.4770 446.6038 446.7306 446.8574 446.9841 447.1109 447.2376 447.3643 447.4910 447.6177 447.7443 447.8710 447.9976 448.1242 448.2508 448.3774 448.5039 448.6305 448.7570 448.8835 449.0101 449.1365 449.2630 449.3895 449.5159 449.6423 449.7688 449.8952 450.0215 450.1479 450.2743 450.4006 450.5269 450.6532 450.7795 450.9058 451.0320 451.1583 451.2845 451.4107 451.5369 451.6631 451.7893 451.9154 452.0416 452.1677 452.2938 452.4199 452.5459 452.6720 452.7980 452.9241 453.0501 453.1761 453.3021 453.4280 453.5540 453.6799 453.8058 453.9317 454.0576 454.1835 454.3093 454.4352 454.5610 454.6868 454.8126 454.9384 455.0642 455.1899 455.3156 455.4414 455.5671 455.6927 455.8184 455.9441 456.0697 456.1953 456.3209 456.4465 456.5721 456.6977 456.8232 456.9487 457.0743 457.1998 457.3252 457.4507 457.5762 457.7016 457.8270 457.9524 458.0778 458.2032 458.3285 458.4539 458.5792 458.7045 458.8298 458.9551 459.0804 459.2056 459.3308 459.4561 459.5813 459.7065 459.8316 459.9568 460.0819 460.2070 460.3322 460.4572 460.5823 460.7074 460.8324 460.9575 461.0825 461.2075 461.3324 461.4574 461.5824 461.7073 461.8322 461.9571 462.0820 462.2069 462.3317 462.4566 462.5814 462.7062 462.8310 462.9558 463.0805 463.2053 463.3300 463.4547 463.5794 463.7041 463.8288 463.9534 464.0781 464.2027 464.3273 464.4519 464.5765 464.7010 464.8256 464.9501 465.0746 465.1991 465.3236 465.4480 465.5725 465.6969 465.8213 465.9457 466.0701 466.1945 466.3188 466.4431 466.5675 466.6918 466.8160 466.9403 467.0646 467.1888 467.3130 467.4372 467.5614 467.6856 467.8098 467.9339 468.0580 468.1822 468.3062 468.4303 468.5544 468.6784 468.8025 468.9265 469.0505 469.1745 469.2984 469.4224 469.5463 469.6703 469.7942 469.9180 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Temperature at electronics board [°C], 999=no temperature signal Column 159: Spectrometer control temperature [°C], 999=no temperature signal Column 160: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 161: Temperature in head sensor [°C], 999=no temperature signal Column 162: Humidity in head sensor [%], -9=no humidity signal Column 163: Pressure in head sensor [hPa], -9=no pressure signal Columns 164-709: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 710-1255: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20240427T191426.8Z 8883.801699 550 1 51.22 2 37.62 237.85 164.73 310.58 0.00 1 0.00 1 0 33 1.422e-03 1.408e-03 9.740e-04 9.587e-04 2.885823e+03 1.834293e+02 2.481964e+02 3.729251e+02 2.857778e+02 282.81 -2.00 20.00 -2.00 444.67 0.00e+00 5.175634e-04 1.038000e-04 2.467620e-06 1.627761e-05 1.548486e-04 282.81 -2.00 20.00 -2.00 453.99 0.00e+00 1.339444e-04 8.518296e-06 9.377320e-07 4.267052e-06 1.282232e-05 226.94 -2.00 2.13 -2.00 434.83 0.00e+00 9.639679e+04 1.324510e+05 3.500386e+04 2.269411e+05 2.051822e+05 264.39 -2.00 11.12 -2.00 456.52 0.00e+00 1.366770e-01 2.772058e-02 9.602845e-04 9.232082e-03 4.450209e-02 229.84 -2.00 3.47 -2.00 453.32 0.00e+00 -7.710095e-07 3.417883e-06 4.145694e-07 1.128311e-06 5.406324e-06 282.81 -2.00 20.00 -2.00 454.71 0.00e+00 1.261 0.000 397.00 473.00 4 7.8737e+00 1.0043e-03 3.2027e-03 3.9746e-04 1.4456e-03 2.7241e-02 1.1881e-03 6.7123e-04 2.4115e-04 1.7769e-03 -1.4481e-02 6.9549e-04 9.2176e-05 1.3149e-04 1.0325e-03 2.9955e-04 2.2895e-04 1.3736e-05 3.2484e-05 3.4220e-04 2.3938e-03 1.1952e-04 5.8642e-06 1.5800e-05 1.7422e-04 5.5167e-04 -9.6210e-03 6.4845e-04 1.2167e-05 7.7538e-05 8.7299e-04 4.8239e-05 9.9663e-06 3.8598e-07 5.7916e-07 1.4492e-05 2.7502e-05 1.3674e-05 5.2410e-07 6.9347e-07 1.9654e-05 -8.8538e-03 5.2238e-05 4.4697e-01 8.9447e-02 1.2847e-03 5.5582e-03 1.2486e-01 11 8 0 10 0 0 99.02 18.42 0.95 -0.00885 -0.01013 14 3 1 4 0 3657.940 26.51 20.00 18.42 18.90 29.5 1027.41 -195 108 -158 -140 -487 -152 -104 -165 183 61 -32 -3 117 7 35 -171 -147 -9 -115 -128 -26 -2 52 -98 113 -100 -113 8 167 322 -36 75 104 86 82 90 -1 91 77 87 -28 68 225 21 179 -235 39 67 -215 -135 -67 -70 152 312 64 41 -96 242 49 297 28 299 182 -27 166 219 412 313 137 113 163 254 -50 30 -161 -184 -64 78 -106 101 56 -118 19 55 -8 -139 -8 -81 -58 -15 -92 86 92 -63 -42 86 -63 17 -228 -93 -84 94 100 -217 30 204 94 127 79 -288 -154 -101 -301 -145 -166 -58 -85 -276 -157 -25 -120 -235 98 -79 -280 -212 -252 -14 -78 -153 -79 -286 -245 -137 -30 -135 -88 -10 109 -136 -392 -22 58 -29 105 134 96 104 -33 30 -38 -28 6 29 208 216 -60 133 204 -126 214 119 -55 178 -41 153 -83 52 -130 146 8 -34 110 36 -57 -107 -164 117 -140 225 -130 -136 -91 124 -22 -2 -69 151 -134 119 -175 -13 -99 118 -218 -145 111 -69 -15 -90 28 -132 -151 57 158 319 29 121 337 126 -98 -13 -42 -61 224 -233 -53 -109 -9 -61 120 -37 -3 -14 102 275 93 341 62 77 274 39 -300 -60 -152 -229 168 -125 -154 210 190 395 156 365 329 -71 171 159 327 -81 16 79 -28 -74 -97 -44 70 -234 234 -129 -42 -76 152 -51 9 -103 -151 72 -184 -249 506 25 -54 -329 -10 -150 141 -3 154 -43 51 -18 236 -194 86 -77 -245 -100 -48 -73 57 48 -193 -348 13 -129 163 -78 32 -108 117 176 -76 -265 -165 159 88 26 141 -138 -78 -83 -39 -13 14 62 3 -194 -24 80 76 -13 132 -232 28 -188 78 54 -69 -77 441 72 412 -79 133 -22 -63 98 -138 -25 -133 122 41 -73 -119 -5 51 78 -35 -94 27 -120 -167 5 -41 -76 99 59 81 59 73 200 -3 241 -35 -56 10 -17 -117 137 121 -142 132 -175 -80 -12 96 -58 107 -40 -159 -91 44 69 130 -184 -94 -170 0 -57 10 -38 90 129 -21 -169 115 -76 -249 100 -24 -132 -114 -45 -80 109 61 -120 -54 -207 32 -44 -33 -199 123 -73 222 166 -23 284 64 -246 -33 36 -133 17 -43 -139 95 -53 205 -55 -184 -18 127 318 -71 230 -63 110 -262 -138 -27 212 -219 -11 -55 106 -98 173 118 184 13 112 13 30 -57 -204 -58 -174 23 135 216 -8 24 -104 134 -50 -28 -79 118 -226 -102 46 -3 -71 -22 6 208 -148 -195 106 120 -42 194 36 1 44 29 41 71 -191 47 -25 -31 -31 83 -95 20 102 -202 -200 249 -48 -156 -87 106 177 52 -28 184 19 15 154 98 -88 178 -17 -105 -107 96 -48 -152 -51 99 -41 317 -200 19 42 -65 -94 -130 14 -68 40 -51 204 89 -12 129 -17 46 -226 -124 -59 -166 90 -136 -119 -413 -130 -87 -142 159 53 -28 -3 101 6 31 -151 -129 -8 -102 -115 -23 -2 46 -82 93 -85 -103 7 152 295 -33 69 89 70 66 75 -1 87 74 81 -26 61 195 18 159 -205 33 56 -176 -113 -60 -64 135 281 58 36 -84 210 42 262 26 283 174 -25 159 215 417 298 129 113 159 241 -46 26 -135 -157 -53 65 -93 89 52 -112 18 53 -8 -140 -8 -84 -59 -15 -93 85 92 -63 -42 85 -62 17 -218 -87 -77 88 97 -221 31 216 97 124 75 -272 -148 -100 -304 -146 -165 -56 -82 -263 -150 -25 -119 -241 102 -84 -298 -222 -260 -14 -77 -148 -75 -267 -226 -128 -29 -132 -85 -10 106 -132 -375 -21 56 -27 101 135 99 105 -33 29 -34 -25 6 26 197 211 -62 138 213 -133 226 126 -57 180 -42 152 -85 55 -136 147 8 -31 97 33 -52 -106 -169 118 -137 214 -123 -129 -88 122 -23 -2 -71 152 -132 112 -164 -12 -94 115 -217 -144 107 -65 -14 -84 28 -135 -159 59 159 298 25 111 301 108 -90 -13 -41 -60 219 -227 -51 -104 -9 -55 106 -32 -3 -13 94 251 81 297 50 59 203 29 -231 -46 -112 -164 119 -91 -122 184 174 400 158 383 347 -72 173 147 283 -70 14 78 -28 -76 -99 -45 70 -239 219 -110 -37 -62 131 -48 9 -100 -152 71 -177 -235 501 25 -52 -324 -10 -152 143 -3 163 -45 53 -19 242 -195 86 -76 -236 -95 -46 -70 56 47 -181 -324 11 -112 146 -74 30 -102 111 169 -74 -263 -167 161 89 26 138 -130 -72 -77 -36 -12 14 65 4 -207 -25 81 77 -13 142 -254 31 -201 82 57 -74 -82 471 77 432 -81 136 -23 -66 99 -141 -25 -141 129 41 -74 -124 -5 53 80 -35 -97 27 -118 -163 5 -40 -76 101 61 80 59 73 199 -3 247 -36 -60 11 -19 -126 143 123 -143 132 -181 -85 -13 101 -61 111 -42 -165 -95 46 73 139 -199 -102 -186 0 -64 11 -44 103 146 -24 -190 127 -83 -271 108 -26 -145 -125 -49 -86 115 62 -119 -53 -201 31 -43 -33 -200 125 -77 238 180 -25 307 69 -265 -35 38 -137 17 -44 -143 98 -56 216 -59 -202 -20 142 352 -78 248 -68 119 -289 -153 -30 233 -243 -12 -62 118 -107 185 124 191 13 116 14 33 -62 -223 -64 -188 24 143 229 -8 25 -111 143 -53 -30 -86 129 -252 -114 51 -4 -78 -24 6 230 -165 -217 118 133 -47 218 40 1 49 33 46 80 -214 53 -28 -35 -34 90 -103 22 112 -221 -216 262 -50 -163 -92 114 192 57 -31 199 21 16 173 110 -98 194 -18 -107 -115 102 -49 -159 -54 107 -44 346 -219 21 45 -68 -100 -140 15 -74 44 -56 221 97 -13 140 -19 50 -247 -133 -62