File name: Pandora232s1_Yongin_20240507_L2Fit_fwvt1c2d20221026p1-8.txt File generation date: 20240511T135412.3Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c2p1-8 Local principal investigator: Yongjoo Choi Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 232 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora232_OF_v2d20220714.txt Instrument calibration file used: Pandora232s1_CF_v2d20221026.txt Level 1 file used: Pandora232s1_Yongin_20240507_L1_smca1c2d20221026p1-8.txt Full location name: Hankuk University of Foreign Studies Short location name: Yongin Country of location: South Korea Location latitude [deg]: 37.3380 Location longitude [deg]: 127.2650 Location altitude [m]: 122 Local noon date: 20240507 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: OoB session based on session 1 First and last pixel inside fitting window: 1619 1768 Nominal wavelengths inside fitting window [nm]: 492.0157 492.1371 492.2584 492.3797 492.5011 492.6224 492.7437 492.8649 492.9862 493.1074 493.2286 493.3499 493.4710 493.5922 493.7134 493.8345 493.9556 494.0767 494.1978 494.3189 494.4399 494.5610 494.6820 494.8030 494.9240 495.0450 495.1659 495.2868 495.4078 495.5287 495.6496 495.7704 495.8913 496.0121 496.1329 496.2537 496.3745 496.4953 496.6160 496.7368 496.8575 496.9782 497.0989 497.2195 497.3402 497.4608 497.5814 497.7020 497.8226 497.9432 498.0637 498.1843 498.3048 498.4253 498.5457 498.6662 498.7867 498.9071 499.0275 499.1479 499.2683 499.3886 499.5090 499.6293 499.7496 499.8699 499.9902 500.1104 500.2307 500.3509 500.4711 500.5913 500.7115 500.8316 500.9518 501.0719 501.1920 501.3121 501.4322 501.5522 501.6723 501.7923 501.9123 502.0323 502.1523 502.2722 502.3922 502.5121 502.6320 502.7519 502.8717 502.9916 503.1114 503.2312 503.3510 503.4708 503.5906 503.7103 503.8301 503.9498 504.0695 504.1892 504.3088 504.4285 504.5481 504.6677 504.7873 504.9069 505.0264 505.1460 505.2655 505.3850 505.5045 505.6240 505.7434 505.8629 505.9823 506.1017 506.2211 506.3405 506.4598 506.5792 506.6985 506.8178 506.9371 507.0563 507.1756 507.2948 507.4140 507.5332 507.6524 507.7716 507.8907 508.0099 508.1290 508.2481 508.3672 508.4862 508.6053 508.7243 508.8433 508.9623 509.0813 509.2002 509.3192 509.4381 509.5570 509.6759 509.7948 509.9136 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-251: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 252-401: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20240507T012907.6Z 8893.061893 201 1 46.38 2 33.09 120.04 27.47 147.15 0.00 1 0.00 1 0 15 2.178e-03 2.178e-03 8.730e-04 8.714e-04 3.654176e+03 5.342132e+01 2.653573e+02 -6.000000e+00 1.200592e+02 284.43 -2.00 20.00 -2.00 505.26 0.00e+00 5.887623e-04 2.392369e-05 3.797020e-05 -6.000000e+00 6.106361e-05 284.43 -2.00 20.00 -2.00 500.41 0.00e+00 2.020196e-02 1.716437e-02 2.421832e-02 -6.000000e+00 4.295825e-02 230.62 -2.00 3.44 -2.00 502.01 0.00e+00 1.193 0.000 489.00 513.00 1 7.8568e+00 1.3139e-03 2.8180e-03 -6.0000e+00 3.2912e-03 1.1001e-02 3.4082e-04 5.9881e-04 -6.0000e+00 8.5776e-04 6.3156e-04 5.0379e-04 7.6814e-05 3.1544e-05 -6.0000e+00 1.9829e-04 1.4898e-02 3.1497e-05 10 0 0 10 0 0 97.78 24.16 0.63 0.01490 0.01839 12 2 1 2 0 3864.720 20.00 24.16 18.02 26.62 26.62 6.1 924.43 -177 -233 -355 -47 152 161 633 125 336 450 -65 -65 96 -50 1 -371 -31 -29 140 252 7 204 218 274 453 272 -58 46 106 -212 -392 60 -474 -3 17 -117 -239 -16 -191 -67 22 100 109 27 232 167 73 -61 -148 -113 -456 -508 -409 -445 -345 -23 -259 -41 -14 321 179 215 111 167 103 96 89 20 235 -89 -201 -213 -246 -70 -10 -109 10 -23 -96 127 -351 -171 -156 -50 -58 -302 -10 -2 -335 297 -225 212 173 205 131 8 138 -52 -47 -304 -366 -173 -295 -144 -77 -368 -130 17 -239 -155 28 155 111 188 123 289 478 250 234 203 55 56 -20 314 -107 -198 5 -188 14 -6 65 -87 65 -8 -70 276 54 218 185 465 198 85 31 87 284 22 -185 -463 -186 -267 -173 -230 -352 -47 156 168 656 131 354 467 -69 -68 98 -50 1 -372 -31 -30 146 266 7 215 230 289 480 289 -62 48 109 -214 -389 60 -480 -3 18 -122 -251 -16 -197 -68 22 103 113 29 245 172 77 -63 -151 -116 -452 -504 -401 -437 -340 -24 -263 -42 -14 326 182 221 114 171 105 96 90 20 232 -86 -194 -207 -241 -70 -10 -108 10 -22 -93 123 -335 -164 -150 -49 -58 -302 -10 -2 -326 295 -221 210 174 207 130 8 134 -50 -45 -284 -342 -165 -284 -141 -77 -369 -129 16 -230 -151 28 155 110 187 122 289 481 253 234 199 55 55 -19 307 -105 -194 5 -184 13 -6 63 -85 62 -8 -66 266 52 213 183 454 194 84 31 86 282 22 -179 -447 -176 -253 SQ 20240507T013443.3Z 8893.065779 205 1 47.93 2 32.13 121.78 26.88 149.76 0.00 1 0.00 1 0 15 2.206e-03 2.203e-03 1.107e-03 1.104e-03 3.687416e+03 6.840805e+01 2.703380e+02 -6.000000e+00 1.216040e+02 284.43 -2.00 20.00 -2.00 505.27 0.00e+00 5.184394e-04 3.029621e-05 3.324412e-05 -6.000000e+00 6.185203e-05 284.43 -2.00 20.00 -2.00 500.37 0.00e+00 -1.480549e-02 2.179718e-02 2.388129e-02 -6.000000e+00 4.351480e-02 230.62 -2.00 3.44 -2.00 501.98 0.00e+00 1.180 0.000 489.00 513.00 1 8.0252e+00 1.6661e-03 2.7580e-03 -6.0000e+00 3.3338e-03 1.2112e-02 4.3314e-04 5.9804e-04 -6.0000e+00 8.6894e-04 5.3656e-04 6.1330e-04 9.7521e-05 3.0925e-05 -6.0000e+00 2.0085e-04 1.3360e-02 3.5021e-05 11 1 0 11 16 0 98.01 24.15 0.70 0.01336 0.01761 12 2 1 2 0 3993.620 20.00 24.15 18.04 26.62 26.62 6.1 924.60 -236 -213 -353 192 207 -40 403 86 344 544 102 160 143 -244 -100 -299 113 -22 -14 145 7 158 15 219 676 178 79 159 -5 -545 -229 -49 -234 218 29 -220 -61 8 8 -16 -108 -25 -128 -23 386 87 112 -92 -40 -186 -382 -337 -341 -330 -442 -30 -199 -182 27 111 182 41 90 64 159 -28 191 -41 240 141 -3 -140 -220 -240 85 -354 -58 -220 -339 67 -244 -44 -264 -169 123 -278 -26 -232 -6 129 155 36 233 216 116 97 251 -56 -78 -538 -435 -102 -415 -317 -115 -412 -92 -182 -94 -199 249 -23 -22 104 331 189 322 471 115 225 169 227 -21 271 150 83 31 -43 166 98 198 -241 -11 -250 -3 144 266 84 259 241 -33 19 5 313 -48 11 -312 -70 -366 -77 -227 -207 -353 199 220 -41 421 91 363 567 104 163 151 -255 -104 -311 118 -23 -15 154 8 168 16 233 720 190 84 167 -5 -541 -235 -50 -231 223 31 -236 -65 9 8 -16 -111 -26 -133 -24 408 92 118 -96 -41 -187 -371 -336 -337 -327 -428 -30 -203 -188 28 114 185 43 93 66 163 -29 189 -40 232 135 -3 -133 -211 -233 83 -347 -56 -207 -317 66 -227 -42 -250 -161 118 -272 -25 -227 -6 126 152 36 236 219 115 94 239 -52 -71 -509 -411 -93 -391 -312 -116 -415 -91 -178 -91 -195 246 -23 -22 107 339 195 333 464 118 227 169 222 -21 266 148 82 30 -42 162 96 191 -229 -10 -233 -3 136 257 83 257 242 -32 18 5 304 -47 10 -311 -68 -349 -73 SQ 20240507T014338.0Z 8893.071967 209 1 44.98 2 30.65 124.72 26.03 154.12 0.00 1 0.00 1 0 15 2.133e-03 2.130e-03 1.054e-03 1.051e-03 2.880715e+03 6.345842e+01 2.095868e+02 -6.000000e+00 1.175491e+02 284.43 -2.00 20.00 -2.00 505.24 0.00e+00 5.206129e-04 2.900265e-05 3.354222e-05 -6.000000e+00 5.978515e-05 284.43 -2.00 20.00 -2.00 500.35 0.00e+00 8.883772e-02 2.073785e-02 1.981612e-02 -6.000000e+00 4.205486e-02 230.62 -2.00 3.44 -2.00 501.96 0.00e+00 1.162 0.000 489.00 513.00 1 7.8892e+00 1.5920e-03 2.4858e-03 -6.0000e+00 3.2221e-03 9.6553e-03 4.1163e-04 4.8462e-04 -6.0000e+00 8.3960e-04 6.1250e-04 3.2960e-04 9.2519e-05 2.5310e-05 -6.0000e+00 1.9413e-04 1.7507e-02 2.6215e-05 11 1 0 11 16 0 -21.92 24.15 0.71 0.01751 0.01979 12 2 1 2 0 3747.910 20.01 24.15 18.22 26.62 26.62 6.1 926.18 -138 -51 -467 33 169 55 507 151 382 401 -230 -101 89 -184 -113 -292 -35 -280 364 86 -133 207 225 233 336 351 144 -120 -64 -382 -296 98 -273 10 18 7 -81 18 -15 37 -73 59 283 221 332 50 164 20 -258 3 -303 -372 -403 -401 -236 32 -106 -107 -258 -69 295 233 113 26 157 16 99 -93 119 91 2 -7 -186 -253 -43 -262 104 -304 -116 122 -288 -356 -279 -23 -163 -173 63 -127 -291 148 -51 128 267 267 -26 136 190 -74 -84 -336 -305 -419 -276 -104 -249 -165 13 -109 -183 203 53 125 -251 191 203 398 244 138 143 276 258 175 -118 395 55 -115 99 -15 -2 250 2 -74 151 133 -80 304 165 9 201 68 277 62 165 -6 -88 -96 -191 -34 -379 -458 -136 -51 -456 33 175 58 545 165 416 431 -245 -106 92 -187 -114 -296 -35 -294 392 94 -139 215 234 242 351 366 150 -124 -68 -390 -297 98 -279 10 19 7 -84 19 -16 39 -77 62 287 227 344 52 169 21 -260 3 -303 -362 -388 -388 -235 33 -106 -107 -261 -69 295 235 114 26 157 16 100 -93 118 89 2 -7 -184 -254 -43 -264 102 -295 -111 117 -277 -347 -273 -22 -163 -175 63 -127 -293 149 -50 125 266 265 -25 131 188 -71 -80 -311 -282 -396 -269 -101 -247 -162 12 -104 -174 194 51 123 -251 192 204 402 249 141 144 273 251 168 -113 381 54 -112 96 -15 -2 241 2 -69 138 128 -77 281 157 8 196 67 274 62 165 -6 -89 -96 -186 -32 -353 -429 SQ 20240507T015926.1Z 8893.082941 216 1 44.63 2 28.16 130.52 24.82 162.42 0.00 1 0.00 1 0 15 2.096e-03 2.096e-03 1.051e-03 1.048e-03 3.002360e+03 6.338748e+01 2.135260e+02 -6.000000e+00 1.155284e+02 284.43 -2.00 20.00 -2.00 505.24 0.00e+00 5.255555e-04 2.890623e-05 3.341979e-05 -6.000000e+00 5.875712e-05 284.43 -2.00 20.00 -2.00 500.35 0.00e+00 7.072273e-03 2.070172e-02 2.159238e-02 -6.000000e+00 4.133078e-02 230.62 -2.00 3.44 -2.00 501.96 0.00e+00 1.134 0.000 489.00 513.00 1 7.8879e+00 1.5895e-03 2.5562e-03 -6.0000e+00 3.1666e-03 1.0442e-02 4.1068e-04 5.1604e-04 -6.0000e+00 8.2512e-04 6.1931e-04 3.5191e-04 9.2185e-05 2.5553e-05 -6.0000e+00 1.9079e-04 1.4662e-02 4.5489e-05 11 1 0 11 16 0 62.72 24.16 0.78 0.01466 0.01710 12 2 1 2 0 3718.940 20.00 24.16 19.01 26.62 26.62 6.2 931.07 -163 -266 -213 58 144 -38 281 145 438 424 -122 121 -245 -31 -76 -328 -94 -86 176 299 -79 172 198 112 375 299 130 -167 104 -187 -430 94 -427 206 -7 -135 -199 -90 100 -80 69 17 368 54 226 125 217 50 -38 23 -514 -489 -377 -389 -265 30 -208 16 -10 227 123 116 97 -43 3 -56 135 2 256 92 45 -208 -131 -132 40 -97 25 -281 -347 11 -548 -249 -179 -12 214 3 68 -59 -75 101 51 -27 113 -40 -55 213 55 36 -113 -187 -459 -217 -317 -20 -233 -200 50 -78 -224 20 3 -195 91 193 256 351 533 356 79 21 38 268 -238 297 4 -89 -7 -7 191 121 195 -201 208 -85 43 86 229 12 47 410 167 178 7 -62 46 -122 -220 -136 -356 -294 -162 -266 -208 59 150 -41 304 159 477 456 -130 127 -254 -32 -77 -333 -96 -91 190 310 -82 179 206 116 392 313 135 -173 110 -191 -433 95 -437 217 -7 -142 -207 -92 106 -84 73 17 374 55 234 130 224 51 -38 24 -516 -478 -364 -377 -264 31 -208 17 -10 227 123 117 98 -44 3 -56 138 2 255 90 43 -205 -130 -133 40 -98 25 -273 -335 10 -529 -243 -175 -11 214 3 65 -59 -72 97 50 -26 113 -40 -54 205 55 34 -107 -173 -427 -206 -310 -20 -231 -198 48 -75 -213 19 3 -193 91 195 259 356 543 363 80 21 38 258 -229 287 4 -86 -7 -7 184 117 186 -188 192 -78 39 80 219 12 46 405 166 177 7 -63 46 -122 -215 -129 -333 -275 SQ 20240507T020807.6Z 8893.088977 220 1 45.23 2 26.88 134.07 24.34 167.26 0.00 1 0.00 1 0 15 2.165e-03 2.160e-03 1.016e-03 1.013e-03 3.002190e+03 6.155490e+01 2.126647e+02 -6.000000e+00 1.193554e+02 284.43 -2.00 20.00 -2.00 505.27 0.00e+00 5.253228e-04 2.784209e-05 3.365203e-05 -6.000000e+00 6.070308e-05 284.43 -2.00 20.00 -2.00 500.40 0.00e+00 1.713667e-02 1.998821e-02 2.200390e-02 -6.000000e+00 4.269826e-02 230.62 -2.00 3.44 -2.00 502.01 0.00e+00 1.121 0.000 489.00 513.00 1 7.8507e+00 1.5306e-03 2.5664e-03 -6.0000e+00 3.2714e-03 1.0482e-02 3.9671e-04 5.2318e-04 -6.0000e+00 8.5239e-04 6.4351e-04 2.1110e-04 8.9591e-05 2.4857e-05 -6.0000e+00 1.9711e-04 1.3977e-02 5.2803e-05 11 1 0 11 16 0 97.77 24.17 0.76 0.01398 0.01544 12 2 1 2 0 3768.870 19.99 24.17 19.55 26.62 26.62 6.2 933.67 44 -314 -288 24 253 261 427 85 143 410 16 256 -39 -112 -79 -345 194 -65 144 43 -148 106 86 194 424 185 -91 -86 7 -270 -172 434 -220 84 72 -130 26 16 79 -150 -44 -127 9 -33 358 25 81 -38 138 -126 -291 -365 -453 -466 -153 1 -310 -297 100 81 175 207 146 70 180 -15 204 -103 235 10 66 -261 -276 -145 12 -145 -146 -312 -192 9 -620 -197 -327 -88 -57 -137 -88 -149 -200 247 -65 214 90 355 -209 98 176 -296 -119 -396 -248 -117 -416 -225 -338 -193 -205 39 32 -242 -59 186 80 76 342 370 397 427 129 205 217 296 -44 205 210 245 87 -80 18 -3 231 19 124 107 -200 310 94 143 202 175 118 -66 104 97 -18 -42 -292 -250 -349 -199 42 -302 -284 25 266 279 443 90 150 424 17 272 -41 -115 -81 -355 201 -66 149 45 -156 111 90 204 448 196 -96 -90 7 -279 -175 441 -227 85 76 -138 28 16 81 -152 -45 -130 9 -35 376 27 85 -39 141 -125 -294 -361 -442 -457 -154 1 -315 -304 102 82 177 211 149 72 183 -15 201 -100 226 9 65 -260 -264 -140 12 -140 -139 -307 -187 8 -607 -194 -309 -83 -55 -133 -85 -145 -195 240 -63 213 91 358 -209 95 168 -276 -114 -372 -233 -112 -391 -220 -339 -193 -202 38 31 -236 -58 186 81 78 349 379 410 442 132 206 215 288 -43 201 206 240 85 -79 18 -3 223 18 116 99 -185 291 90 140 200 176 119 -67 105 94 -17 -42 -289 -240 -330 -188