File name: Pandora232s1_Yongin_20241015_L2Fit_fwvt1c3d20221026p1-8.txt File generation date: 20250512T103538.5Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c3p1-8 Local principal investigator: Yongjoo Choi Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 232 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora232_OF_v2d20220714.txt Instrument calibration file used: Pandora232s1_CF_v3d20221026.txt Level 1 file used: Pandora232s1_Yongin_20241015_L1_smca1c3d20221026p1-8.txt Full location name: Hankuk University of Foreign Studies Short location name: Yongin Country of location: South Korea Location latitude [deg]: 37.3380 Location longitude [deg]: 127.2650 Location altitude [m]: 122 Local noon date: 20241015 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: offical since 20250506 First and last pixel inside fitting window: 1619 1768 Nominal wavelengths inside fitting window [nm]: 492.0362 492.1576 492.2789 492.4003 492.5216 492.6429 492.7642 492.8855 493.0067 493.1280 493.2492 493.3704 493.4916 493.6128 493.7339 493.8551 493.9762 494.0973 494.2184 494.3394 494.4605 494.5815 494.7026 494.8236 494.9446 495.0655 495.1865 495.3074 495.4284 495.5493 495.6701 495.7910 495.9119 496.0327 496.1535 496.2743 496.3951 496.5159 496.6366 496.7574 496.8781 496.9988 497.1195 497.2402 497.3608 497.4815 497.6021 497.7227 497.8433 497.9638 498.0844 498.2049 498.3254 498.4459 498.5664 498.6869 498.8073 498.9278 499.0482 499.1686 499.2890 499.4093 499.5297 499.6500 499.7703 499.8906 500.0109 500.1312 500.2514 500.3716 500.4918 500.6120 500.7322 500.8524 500.9725 501.0926 501.2128 501.3329 501.4529 501.5730 501.6930 501.8131 501.9331 502.0531 502.1730 502.2930 502.4129 502.5328 502.6528 502.7726 502.8925 503.0124 503.1322 503.2520 503.3718 503.4916 503.6114 503.7311 503.8509 503.9706 504.0903 504.2100 504.3296 504.4493 504.5689 504.6885 504.8081 504.9277 505.0473 505.1668 505.2864 505.4059 505.5254 505.6448 505.7643 505.8838 506.0032 506.1226 506.2420 506.3614 506.4807 506.6001 506.7194 506.8387 506.9580 507.0773 507.1965 507.3157 507.4350 507.5542 507.6734 507.7925 507.9117 508.0308 508.1499 508.2690 508.3881 508.5072 508.6262 508.7453 508.8643 508.9833 509.1023 509.2212 509.3402 509.4591 509.5780 509.6969 509.8158 509.9346 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-251: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 252-401: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20241015T040946.1Z 9054.173450 366 1 46.38 2 47.67 197.87 130.50 61.41 0.00 1 0.00 1 0 15 1.857e-03 1.847e-03 6.298e-04 6.287e-04 3.790532e+03 3.877068e+01 2.691921e+02 -6.000000e+00 1.029579e+02 286.14 -2.00 20.00 -2.00 505.26 0.00e+00 6.446501e-04 1.735040e-05 4.083057e-05 -6.000000e+00 5.231595e-05 286.14 -2.00 20.00 -2.00 500.43 0.00e+00 -2.219802e-03 1.228322e-02 2.539297e-02 -6.000000e+00 3.638970e-02 226.38 -2.00 3.44 -2.00 502.03 0.00e+00 1.482 0.000 489.00 513.00 1 7.3640e+00 9.4160e-04 3.1609e-03 -6.0000e+00 2.7913e-03 1.0063e-02 2.4361e-04 6.1867e-04 -6.0000e+00 7.2619e-04 9.9345e-04 5.1501e-04 5.5506e-05 3.1523e-05 -6.0000e+00 1.6908e-04 4.5721e-03 -1.2800e-05 10 0 0 10 0 0 99.89 24.22 0.96 0.00457 0.00814 22 4 1 2 0 2107.990 19.99 24.22 30.20 26.62 26.62 6.6 981.51 -93 -79 -233 91 154 103 403 139 298 316 -42 142 -146 6 -143 -131 -11 -77 260 179 87 103 122 169 371 178 35 -21 16 -285 -185 152 -292 -14 -26 -25 -171 66 -10 -48 -48 -31 79 14 174 5 101 -80 48 -125 -320 -416 -272 -479 -164 -160 -197 -125 -56 239 81 222 53 208 57 68 34 14 124 124 -59 -38 -249 -223 29 -128 -235 -280 -164 -81 -237 -187 -188 -240 -26 -106 -215 -144 -126 219 15 128 216 119 71 37 28 -62 -30 -321 -342 -321 -386 -130 -205 -336 -98 -39 -72 -6 -57 19 79 183 166 370 433 380 255 141 210 172 -6 112 158 149 91 -21 -136 87 123 -20 132 17 -56 293 52 207 280 210 104 71 110 73 20 8 -299 -275 -341 -259 -92 -77 -233 92 157 107 417 146 312 326 -44 146 -148 6 -145 -133 -11 -79 269 187 91 109 128 178 392 188 36 -22 16 -285 -187 153 -293 -14 -27 -27 -180 68 -10 -49 -48 -31 81 15 182 5 106 -82 49 -127 -315 -408 -264 -467 -161 -162 -200 -128 -57 243 83 227 54 213 58 68 35 14 122 123 -58 -36 -243 -221 29 -127 -229 -274 -159 -78 -230 -183 -181 -233 -26 -106 -214 -143 -125 217 15 127 218 120 71 37 27 -60 -29 -299 -318 -304 -370 -127 -206 -337 -96 -38 -71 -6 -56 19 78 183 166 371 437 385 256 139 208 168 -6 110 156 146 90 -21 -133 85 118 -19 126 16 -53 282 50 203 278 207 103 70 110 73 20 8 -290 -266 -324 -247 SQ 20241015T041559.7Z 9054.177774 370 1 46.62 2 48.07 199.87 129.44 62.75 0.00 1 0.00 1 0 15 1.729e-03 1.721e-03 3.999e-04 3.993e-04 3.115083e+03 2.420333e+01 2.233924e+02 -6.000000e+00 9.584971e+01 286.14 -2.00 20.00 -2.00 505.26 0.00e+00 5.451655e-04 1.102546e-05 3.503231e-05 -6.000000e+00 4.870450e-05 286.14 -2.00 20.00 -2.00 500.44 0.00e+00 -3.825563e-02 7.786551e-03 2.111978e-02 -6.000000e+00 3.387994e-02 226.38 -2.00 3.44 -2.00 502.04 0.00e+00 1.494 0.000 489.00 513.00 1 6.4421e+00 5.9697e-04 2.8938e-03 -6.0000e+00 2.5988e-03 8.7260e-03 1.5473e-04 5.1779e-04 -6.0000e+00 6.7617e-04 2.5070e-03 6.0800e-04 3.5262e-05 2.6634e-05 -6.0000e+00 1.5740e-04 6.4075e-03 -2.7572e-05 10 0 0 10 0 0 99.99 24.23 1.05 0.00641 0.01062 149 24 1 2 0 312.860 20.00 24.23 30.11 26.62 26.73 6.7 981.83 -27 -45 -116 41 37 187 422 172 258 226 36 111 -30 -73 -37 -134 -6 -39 135 66 39 163 156 215 362 136 -39 -85 71 -273 -257 107 -186 53 -9 -83 -157 65 -20 -106 23 6 74 109 175 38 130 -46 -13 -151 -282 -375 -402 -416 -212 -181 -168 -111 -129 8 52 160 20 174 96 50 15 -25 189 44 -1 -52 -126 -150 117 -45 -138 -182 -227 -175 -351 -176 -217 -173 -57 -31 -155 -67 -119 134 -29 70 131 82 139 49 103 -178 -5 -317 -316 -290 -387 -142 -284 -289 -156 -6 -60 -34 -21 -33 15 179 243 384 415 373 210 145 250 82 154 261 108 -107 197 -12 -56 238 80 -28 110 81 92 127 167 54 180 145 38 -44 118 50 -41 43 -196 -204 -309 -102 -26 -44 -114 41 37 193 444 179 268 238 37 114 -31 -75 -37 -137 -6 -40 142 68 41 171 163 225 380 143 -41 -88 73 -273 -260 108 -186 55 -10 -88 -163 67 -21 -110 24 6 75 113 182 40 135 -47 -13 -153 -276 -369 -392 -407 -208 -183 -170 -113 -131 8 52 163 21 177 97 50 15 -25 186 42 -1 -50 -123 -148 117 -45 -134 -179 -221 -170 -343 -169 -209 -168 -56 -31 -154 -67 -119 133 -29 69 132 83 138 49 101 -169 -5 -298 -297 -278 -374 -140 -285 -290 -154 -6 -59 -33 -21 -33 16 178 242 384 418 377 210 147 248 80 149 256 107 -105 194 -11 -55 233 78 -27 105 77 87 123 161 53 179 142 37 -43 118 50 -41 42 -194 -196 -293 -97 SQ 20241015T042429.2Z 9054.183671 374 1 51.74 2 48.69 202.56 127.96 64.52 0.00 1 0.00 1 0 15 1.708e-03 1.703e-03 4.177e-04 4.170e-04 3.176127e+03 2.531402e+01 2.297296e+02 -6.000000e+00 9.469602e+01 286.14 -2.00 20.00 -2.00 505.26 0.00e+00 5.681293e-04 1.149578e-05 3.630945e-05 -6.000000e+00 4.811835e-05 286.14 -2.00 20.00 -2.00 500.44 0.00e+00 -3.072678e-02 8.146584e-03 2.115801e-02 -6.000000e+00 3.347247e-02 226.38 -2.00 3.44 -2.00 502.03 0.00e+00 1.512 0.000 489.00 513.00 1 6.6558e+00 6.2426e-04 2.9251e-03 -6.0000e+00 2.5675e-03 1.1243e-02 1.6169e-04 5.2334e-04 -6.0000e+00 6.6804e-04 2.0174e-03 6.0098e-04 3.6795e-05 2.7890e-05 -6.0000e+00 1.5551e-04 6.1457e-03 -2.6809e-05 10 0 0 10 0 0 99.98 24.22 1.00 0.00615 0.01031 67 11 1 2 0 772.220 20.00 24.22 30.23 26.62 26.73 6.7 982.19 -58 -12 -147 -15 86 91 380 212 228 271 14 211 -66 -80 -71 -77 -23 -51 143 177 -7 142 165 165 345 185 -20 -57 7 -274 -158 76 -253 -4 -44 -95 -202 30 -34 -43 52 0 126 146 230 64 101 -38 -50 -186 -225 -331 -313 -360 -179 -212 -231 -210 -132 69 100 175 13 206 79 52 49 -4 156 115 -65 -53 -201 -136 4 -168 -205 -148 -148 -187 -207 -142 -136 -153 -124 -151 -121 -116 -163 109 11 154 152 55 126 99 130 -198 47 -390 -380 -203 -384 -187 -320 -254 -152 44 -7 105 22 -11 14 137 200 323 430 309 253 94 130 29 31 324 34 -35 143 74 -68 218 116 65 99 19 83 135 179 144 279 85 55 30 83 -25 18 -36 -152 -283 -275 -146 -56 -12 -145 -15 88 96 397 224 240 282 14 219 -67 -80 -70 -77 -23 -53 150 187 -7 147 174 171 360 193 -21 -61 8 -277 -157 75 -256 -4 -46 -100 -209 32 -35 -44 53 0 131 150 239 67 104 -38 -52 -186 -223 -328 -306 -354 -177 -212 -236 -217 -136 71 103 181 13 208 81 53 48 -4 154 112 -63 -52 -198 -135 3 -164 -201 -142 -141 -178 -198 -138 -132 -150 -121 -148 -119 -114 -160 107 11 154 152 55 126 97 128 -190 45 -368 -359 -191 -373 -185 -318 -251 -152 43 -7 103 22 -11 14 139 203 328 430 310 256 94 127 28 30 321 33 -34 139 71 -67 215 113 62 94 19 80 129 175 140 274 85 55 30 82 -24 18 -36 -149 -275 -264 -140 SQ 20241015T064558.7Z 9054.281930 456 1 4.27 2 67.15 238.10 101.43 87.93 0.00 1 0.00 1 0 15 2.374e-03 2.369e-03 1.515e-03 1.513e-03 4.314774e+03 9.402947e+01 3.026663e+02 -6.000000e+00 1.315953e+02 286.13 -2.00 20.00 -2.00 505.27 0.00e+00 1.558472e-03 4.180789e-05 8.905718e-05 -6.000000e+00 6.686860e-05 286.13 -2.00 20.00 -2.00 500.51 0.00e+00 3.574109e-02 2.949094e-02 3.144036e-02 -6.000000e+00 4.651358e-02 226.37 -2.00 3.44 -2.00 502.09 0.00e+00 2.555 0.000 489.00 513.00 1 6.2936e+00 2.2607e-03 4.9477e-03 -6.0000e+00 3.5679e-03 2.3877e-03 5.8333e-04 7.3541e-04 -6.0000e+00 9.2820e-04 2.4497e-03 6.4460e-04 1.3325e-04 4.1951e-05 -6.0000e+00 2.1610e-04 -1.2253e-02 7.1013e-05 12 1 1 12 1 1 64.28 24.21 1.04 -0.01225 -0.00778 3 8 1 2 0 1065.910 20.00 24.21 31.36 26.62 26.62 6.6 987.70 -71 -157 -386 -32 162 217 607 278 84 358 -101 110 -328 -72 -209 -426 -105 140 419 69 47 227 225 165 451 284 -1 -19 369 -520 -215 -102 -254 178 -109 -160 -311 274 220 -175 242 -110 -94 55 56 83 -35 -90 32 8 -276 -422 -478 -379 -218 23 -237 -149 -133 236 -67 312 33 238 145 341 272 66 108 85 222 74 -312 -143 157 -321 -316 -294 -241 -203 -476 40 -34 -363 -44 -378 -219 66 -108 136 -126 -183 77 312 6 -51 303 -160 202 -395 -554 -282 -423 -1 -35 -101 -128 -136 -70 192 128 -139 71 124 422 339 509 189 289 172 96 59 74 386 -29 -125 146 64 -105 301 -120 -230 81 160 145 -41 79 -15 382 7 93 -126 333 63 160 -66 -106 -419 -224 -280 -69 -151 -384 -32 165 221 628 292 86 370 -103 111 -333 -72 -207 -425 -106 141 434 71 48 234 232 171 470 296 -1 -20 377 -523 -213 -101 -255 182 -114 -165 -323 281 222 -179 247 -112 -97 57 57 86 -36 -93 32 8 -276 -412 -461 -368 -217 23 -241 -153 -137 241 -69 320 34 246 148 343 274 66 106 84 217 73 -306 -142 158 -320 -308 -287 -233 -195 -462 40 -32 -354 -43 -378 -218 65 -107 135 -124 -183 77 316 6 -50 294 -155 190 -374 -526 -266 -407 -1 -35 -102 -128 -133 -68 188 127 -139 71 125 428 340 514 192 291 173 95 58 73 384 -28 -123 144 63 -102 294 -119 -223 78 154 140 -40 77 -15 380 7 93 -126 334 63 161 -66 -105 -406 -217 -272 SQ 20241015T070255.6Z 9054.293699 469 1 51.74 2 70.07 241.33 98.14 90.36 0.00 1 0.00 1 0 15 2.032e-03 2.017e-03 3.432e-04 3.428e-04 4.923054e+03 2.152208e+01 3.473364e+02 -6.000000e+00 1.126534e+02 286.13 -2.00 20.00 -2.00 505.29 0.00e+00 1.764403e-03 9.473820e-06 1.013841e-04 -6.000000e+00 5.724894e-05 286.13 -2.00 20.00 -2.00 500.53 0.00e+00 8.350970e-02 6.676835e-03 3.493359e-02 -6.000000e+00 3.983271e-02 226.37 -2.00 3.44 -2.00 502.11 0.00e+00 2.901 0.000 489.00 513.00 1 6.0340e+00 5.1169e-04 5.5919e-03 -6.0000e+00 3.0552e-03 -4.0695e-03 1.3188e-04 8.2625e-04 -6.0000e+00 7.9522e-04 3.0017e-03 1.0793e-03 3.0216e-05 4.7822e-05 -6.0000e+00 1.8503e-04 9.4374e-03 -6.1090e-05 10 0 0 10 0 0 99.95 24.21 1.03 0.00944 0.01692 138 22 1 2 0 374.890 20.00 24.21 31.16 26.62 26.62 6.6 986.29 -146 -65 -158 32 58 157 429 243 311 273 54 116 -58 -73 -172 -208 -60 -80 228 81 1 162 236 202 373 210 108 -84 103 -295 -268 -26 -309 80 65 -106 -84 12 0 -48 19 52 178 136 202 59 156 27 -38 -78 -343 -437 -443 -473 -151 -135 -144 -152 -42 43 98 189 132 156 116 1 16 -2 84 8 -96 -41 -235 -128 2 -173 -239 -239 -157 -232 -306 -193 -259 -215 -138 -124 -187 -105 -118 82 2 154 138 163 122 116 179 -190 -33 -410 -472 -466 -479 -141 -303 -275 -103 -59 -60 24 34 44 117 195 335 436 480 417 223 160 246 136 121 300 164 -7 168 -2 -27 174 195 2 151 115 -92 130 175 95 233 224 22 31 47 80 2 -36 -232 -360 -411 -194 -138 -62 -156 32 58 162 438 252 322 279 55 119 -58 -72 -173 -205 -60 -82 234 84 1 168 245 210 391 220 113 -87 104 -294 -263 -26 -309 81 67 -110 -86 12 0 -48 19 53 184 139 209 62 161 27 -39 -78 -342 -425 -426 -459 -151 -136 -146 -155 -43 43 99 192 135 159 117 1 17 -2 82 7 -94 -40 -230 -127 2 -171 -232 -234 -152 -224 -296 -189 -256 -209 -136 -123 -186 -104 -117 81 2 152 139 164 120 115 173 -183 -31 -389 -449 -441 -458 -138 -303 -275 -102 -59 -59 23 34 44 116 196 338 441 489 427 226 160 247 134 119 297 164 -7 168 -2 -26 173 192 2 147 111 -88 125 173 93 231 225 22 31 47 80 2 -37 -230 -355 -400 -189 SQ 20241015T070810.0Z 9054.297339 473 1 51.70 2 70.98 242.30 97.12 91.10 0.00 1 0.00 1 0 15 2.132e-03 2.124e-03 8.130e-04 8.118e-04 5.172342e+03 5.155446e+01 3.598011e+02 -6.000000e+00 1.181583e+02 286.13 -2.00 20.00 -2.00 505.29 0.00e+00 2.052605e-03 2.241625e-05 1.163165e-04 -6.000000e+00 6.004218e-05 286.13 -2.00 20.00 -2.00 500.51 0.00e+00 1.234827e-01 1.587038e-02 3.776771e-02 -6.000000e+00 4.177055e-02 226.37 -2.00 3.44 -2.00 502.09 0.00e+00 3.032 0.000 489.00 513.00 1 7.6233e+00 1.2153e-03 6.0004e-03 -6.0000e+00 3.2039e-03 3.1448e-03 3.1327e-04 8.7312e-04 -6.0000e+00 8.3372e-04 5.9678e-04 8.6656e-04 7.1367e-05 5.1656e-05 -6.0000e+00 1.9405e-04 6.2553e-03 -3.2266e-05 10 0 0 10 0 0 99.99 24.21 0.92 0.00626 0.01227 85 14 1 2 0 608.150 20.00 24.21 31.17 26.62 26.62 6.7 986.72 -207 -140 -159 36 159 99 461 71 227 171 -36 100 -103 -66 -176 -128 -28 -105 124 272 -150 179 281 419 330 207 166 51 116 -371 -56 -132 -304 -46 -14 -60 -105 19 4 -142 -81 93 110 322 245 91 46 41 -40 -13 -349 -458 -379 -501 -54 -166 -386 -37 49 204 131 271 167 115 118 186 5 72 49 39 -105 -69 -233 -195 -88 -151 -153 -240 -196 -364 -272 -288 -44 -286 -107 -71 -175 -108 -379 118 -58 163 210 288 96 142 19 -198 55 -385 -320 -378 -373 -223 -208 -290 -186 -7 -34 -46 134 166 47 319 174 439 445 559 216 58 316 -13 150 203 359 6 158 -211 0 66 199 -85 -11 -23 -168 190 243 54 70 154 37 93 200 192 -96 18 -218 -388 -352 -250 -198 -135 -158 36 162 103 470 73 235 174 -38 103 -104 -66 -175 -128 -28 -108 127 280 -155 185 290 433 345 216 172 53 117 -373 -55 -131 -306 -46 -15 -64 -109 19 4 -143 -82 95 113 334 257 96 49 43 -41 -13 -350 -449 -367 -489 -54 -166 -395 -38 51 210 134 281 173 120 121 189 5 71 48 39 -103 -69 -225 -191 -87 -149 -147 -235 -190 -353 -265 -283 -44 -274 -104 -70 -171 -106 -371 115 -57 163 213 292 96 138 18 -191 52 -357 -296 -357 -364 -219 -210 -291 -185 -7 -33 -46 134 168 47 317 174 440 451 567 218 57 319 -13 148 203 359 6 159 -212 0 66 197 -83 -11 -22 -160 183 241 52 68 153 37 93 202 194 -97 18 -214 -371 -343 -244